Monitoring results Evidence: facility-reported
63 distinct results, 5 reporting years (2015 to 2019)
Most recent sample Apr 06, 2020 · Monitoring
Compliance and enforcement records Evidence: SMARTS record
2 inspections · 1 violation record · 1 enforcement action
Counts as published in SMARTS; not a compliance determination · Details
SMARTS TMDL records Evidence: SMARTS-reported
0 records
TMDL records

Each label shows where a statement comes from. How to read the labels.

Overview and location

Reported facility location HUC12 watershed Corroborated receiving water 2026 Integrated Report waterbodies nearby

Open this facility on the statewide map

Reported location Evidence: facility-reported

Coordinates
33.93852, -118.05136
Precision
5 decimal places
Shared point
2 permits report this exact point
Matches application record
same

Facility location as reported by the discharger in SMARTS; not a discharge point or outfall.

Facility address
10600 Painter Ave, Santa Fe Springs 90670
Regional Water Board
4 — Los Angeles

HUC12 watershed Evidence: spatial

  • Coyote Creek-San Gabriel River HUC12 180701060606

The facility's reported location lies within this HUC12 watershed (spatial derivation); it is not a discharge location.

Permits and applications Evidence: SMARTS record

Current permit record

Permit type
Industrial
Application type
Notice of Intent (WDID code I)
Status
Terminated
Operator
Hazardous Waste Trans Services Inc
Primary industry (SIC)
4212-Local Trucking Without Storage
Application ID
191779
NOI processed
Jul 30, 2004
Termination effective
Dec 21, 2020
Last certified
Jun 15, 2015
Facility size
50625 SqFt
Impervious area
100 %

Retrieved from SMARTS Oct 20, 2026. Verify against SMARTS before relying on it.

Permit history

Storm water applications for this WDID, newest first
ApplicationTypeStatusProcessedTerminatedCertified
191779 IndustrialTerminatedJul 30, 2004 Dec 21, 2020Jun 15, 2015

Every storm water application SMARTS records for this WDID, newest first (1).

Receiving water

Reported by the facility Evidence: facility-reported
Ocean
Discharges directly / indirectly
N / Y (as answered in the permit application)

Evidence: not confirmed Not matchable to a single waterbody

Receiving-water text as reported by the discharger in SMARTS; no waterbody identification has been confirmed.

Impaired waters and TMDLs

Two kinds of information, kept apart: 2026 Integrated Report waterbodies near the reported location (geographic proximity only), and TMDL records that SMARTS lists for this facility. Neither establishes where the facility discharges; see Receiving water for the facility's own statement.

Nearby waterbodies Evidence: geographic proximity

Spatial proximity only; discharge pathway not established. Being near a waterbody does not mean the facility discharges to it.

No 2026 Integrated Report waterbody lies within the proximity threshold of the reported location.

SMARTS TMDL records Evidence: SMARTS-reported

No TMDL records for this facility in the SMARTS TMDL export.

Reported monitoring results Evidence: facility-reported

Numeric Action Level (NAL) screening is being independently validated and is not shown. Nothing on this page states whether a result exceeded a NAL.

63 distinct measurements across 3 parameters, most recent sample Apr 06, 2020.

By reporting year

Distinct results by reporting year
Reporting year (July–June)Distinct resultsParametersWith several versionsFirst sampleLast sample
2019123 0 Nov 20, 2019Apr 06, 2020
2018123 0 Nov 29, 2018Feb 14, 2019
2017123 0 Jan 08, 2018Mar 21, 2018
2016153 0 Dec 16, 2016Feb 17, 2017
2015123 0 Sep 15, 2015Mar 11, 2016

By parameter

Distinct results by parameter
ParameterUnitsMeasurementsBelow detectionFirst sampleLast sampleResults
Oil and Greasemg/L21 11Sep 15, 2015Apr 06, 2020 Results
pHSU21 0Sep 15, 2015Apr 06, 2020 Results
Total Suspended Solids (TSS)mg/L21 0Sep 15, 2015Apr 06, 2020 Results

All results (63 distinct rows)

Reported monitoring results, newest first
Sample dateParameterResultUnitsLocation typeEventMethodReportVersions
Apr 06, 2020 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664A 1106653
Apr 06, 2020 pH 6.5 SU Effluent Qualifying Storm Event pH_Paper 1106653
Apr 06, 2020 Total Suspended Solids (TSS) 23 mg/L Effluent Qualifying Storm Event A2540D 1106653
Mar 10, 2020 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664A 1103436
Mar 10, 2020 pH 6 SU Effluent Qualifying Storm Event pH_Paper 1103436
Mar 10, 2020 Total Suspended Solids (TSS) 71 mg/L Effluent Qualifying Storm Event A2540D 1103436
Nov 27, 2019 Oil and Grease 3.7 mg/L Effluent Qualifying Storm Event E1664A 1092425
Nov 27, 2019 pH 6.7 SU Effluent Qualifying Storm Event pH_Paper 1092425
Nov 27, 2019 Total Suspended Solids (TSS) 50 mg/L Effluent Qualifying Storm Event A2540D 1092425
Nov 20, 2019 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664A 1092421
Nov 20, 2019 pH 6.8 SU Effluent Qualifying Storm Event pH_Paper 1092421
Nov 20, 2019 Total Suspended Solids (TSS) 26.5 mg/L Effluent Qualifying Storm Event A2540D 1092421
Feb 14, 2019 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664B 1043519
Feb 14, 2019 pH 7 SU Effluent Qualifying Storm Event pH_Paper 1043519
Feb 14, 2019 Total Suspended Solids (TSS) 45 mg/L Effluent Qualifying Storm Event A2540D 1043519
Jan 31, 2019 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664B 1043516
Jan 31, 2019 pH 6 SU Effluent Qualifying Storm Event pH_Paper 1043516
Jan 31, 2019 Total Suspended Solids (TSS) 40 mg/L Effluent Qualifying Storm Event A2540D 1043516
Dec 06, 2018 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664B 1032238
Dec 06, 2018 pH 6.5 SU Effluent Qualifying Storm Event pH_Paper 1032238
Dec 06, 2018 Total Suspended Solids (TSS) 10 mg/L Effluent Qualifying Storm Event A2540D 1032238
Nov 29, 2018 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664B 1032232
Nov 29, 2018 pH 6.5 SU Effluent Qualifying Storm Event pH_Paper 1032232
Nov 29, 2018 Total Suspended Solids (TSS) 24 mg/L Effluent Qualifying Storm Event A2540D 1032232
Mar 21, 2018 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664A 998862
Mar 21, 2018 pH 6.5 SU Effluent Qualifying Storm Event pH_Paper 998862
Mar 21, 2018 Total Suspended Solids (TSS) 58 mg/L Effluent Qualifying Storm Event A2540D 998862
Mar 13, 2018 Oil and Grease 1.6 mg/L Effluent Qualifying Storm Event E1664A 996405
Mar 13, 2018 pH 7 SU Effluent Qualifying Storm Event pH_Paper 996405
Mar 13, 2018 Total Suspended Solids (TSS) 11.2 mg/L Effluent Qualifying Storm Event A2540D 996405
Mar 02, 2018 Oil and Grease 2.6 mg/L Effluent Qualifying Storm Event E1664A 996402
Mar 02, 2018 pH 7 SU Effluent Qualifying Storm Event pH_Paper 996402
Mar 02, 2018 Total Suspended Solids (TSS) 46.9 mg/L Effluent Qualifying Storm Event A2540D 996402
Jan 08, 2018 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664A 990105
Jan 08, 2018 pH 7 SU Effluent Qualifying Storm Event pH_Paper 990105
Jan 08, 2018 Total Suspended Solids (TSS) 23.3 mg/L Effluent Qualifying Storm Event A2540D 990105
Feb 17, 2017 Oil and Grease 1.7 mg/L Effluent Qualifying Storm Event E1664A 928977
Feb 17, 2017 pH 7.63 SU Effluent Qualifying Storm Event pH_Field 928977
Feb 17, 2017 Total Suspended Solids (TSS) 29.8 mg/L Effluent Qualifying Storm Event A2540D 928977
Feb 06, 2017 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664A 925916
Feb 06, 2017 pH 7.03 SU Effluent Qualifying Storm Event pH_Field 925916
Feb 06, 2017 Total Suspended Solids (TSS) 19.5 mg/L Effluent Qualifying Storm Event A2540D 925916
Jan 05, 2017 Oil and Grease 2.8 mg/L Effluent Qualifying Storm Event E1664A 925858
Jan 05, 2017 pH 7 SU Effluent Qualifying Storm Event pH_Paper 925858
Jan 05, 2017 Total Suspended Solids (TSS) 163 mg/L Effluent Qualifying Storm Event A2540D 925858
Dec 30, 2016 Oil and Grease 2.2 mg/L Effluent Qualifying Storm Event E1664A 914397
Dec 30, 2016 pH 7 SU Effluent Qualifying Storm Event pH_Paper 914397
Dec 30, 2016 Total Suspended Solids (TSS) 260 mg/L Effluent Qualifying Storm Event A2540D 914397
Dec 16, 2016 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664A 912493
Dec 16, 2016 pH 7 SU Effluent Qualifying Storm Event pH_Paper 912493

Results are shown exactly as reported by the discharger. Identical rows repeated in the State's export are shown once. Where the export contains different versions of the same sample and parameter, each version is listed and flagged. Details.

Compliance and enforcement records Evidence: SMARTS record

These are records as the State Water Board publishes them in SMARTS, with the source's own types and statuses. They are not a compliance determination or rating. A record listed here is not proof of a violation beyond what the source states, and the absence of records does not establish compliance.

Compliance and enforcement records by type
Record typeRecordsAs publishedDatesRetrievedList
Violations1 1 Violation · 0 Potential (preliminary) · 0 Dismissed Dec 22, 2008 – Dec 22, 2008 Oct 21, 2026 All violations
Enforcement actions1 1 issued · 0 draft · 0 withdrawn, rescinded or superseded May 06, 2010 – May 06, 2010 Oct 21, 2026 All actions
Inspections2inspections, not findings Feb 26, 2020 – Jan 26, 2021 Oct 21, 2026 All inspections
Annual reports6certified reports (contents not shown) 2015 – 2020 Oct 21, 2026 All reports
Water-quality-based corrective action reports0reports, by parameter — Oct 21, 2026

Each record type is counted by its own SMARTS identifier. A violation and the enforcement action that cites it are two records in two lists; they are never added together.

Chronological record history (10 records, newest first)
Compliance and enforcement records, newest first
DateRecordIDType or purposeStatus as publishedDetail
Jan 26, 2021 Inspections 2050383 NOT FinalizedNo Further Action
Dec 21, 2020 Annual reports 1069112 Annual report 2020 —
Jul 13, 2020 Annual reports 986406 Annual report 2019 —
Feb 26, 2020 Inspections 2046770 B Type compliance FinalizedNo Further Action
Jun 19, 2019 Annual reports 953979 Annual report 2018 —
Jul 16, 2018 Annual reports 939397 Annual report 2017 —
Jun 21, 2017 Annual reports 878663 Annual report 2016 —
Jul 06, 2016 Annual reports 845737 Annual report 2015 —
May 06, 2010 Enforcement actions 403620 SEL (Staff Enforcement Letter) Historical
Dec 22, 2008 Violations 843284 Deficient BMP Implementation ViolationReport

Sources and provenance

Sources behind this page
InformationSourceRetrieved or published
Permit, location, receiving-water textSMARTS Industrial Application Specific DataOct 20, 2026
Permit historySMARTS Storm Water ApplicationsOct 20, 2026
Monitoring resultsSMARTS Industrial Parameter DataOct 20, 2026
Watershed Boundary Dataset HU2 GeoPackages 15, 16, 18 (WBDHU12)USGS2026-10-22
2026 California Integrated Report, Appendix A: 2026 303(d) List (final)SWRCB2026-10-22
Final_2026_Rivers_and_Streams + Final_2026_Lakes_and_Reservoirs (FeatureServer 0)SWRCB GIS2026-10-22
SMARTS TMDL requirementsSMARTS2026-10-21

Relationships computed 2026-10-22 with methods facility_huc12/1, proximity/1, receiving_water/2, tmdl_reference/1, waterbody_huc12_ovl/1, waterbody_huc12_pub/1; proximity threshold 1.0 km.

How to read the evidence labels

Records are shown as published and are not compliance determinations. How geographic context is derived.