Jensen Precast

Terminated WDID 5S34I017825 Sacramento, Sacramento County Region 5S · Central Valley (Sacramento)

At a glance

Permit Evidence: SMARTS record
Terminated Industrial
Notice of Intent (WDID code I) · Permits and applications
Location Evidence: facility-reported
Sacramento, Sacramento County
Region 5S · Central Valley (Sacramento) · Location · Statewide map
Receiving water
Sacramento River (as reported by the facility)
Evidence: candidate, awaiting review Details
Identified receiving water on the 2026 303(d) list
Not established
Shown only when the reported receiving water is identified and corroborated.
2026 Integrated Report waters within 1.0 km Evidence: geographic proximity
1 waterbody; 0 on the 2026 303(d) list
Proximity only; not a discharge pathway · Nearby waterbodies
Monitoring results Evidence: facility-reported
969 distinct results, 9 reporting years (2015 to 2023)
Most recent sample Apr 04, 2024 · Monitoring
Compliance and enforcement records Evidence: SMARTS record
3 inspections · 8 violation records · 10 enforcement actions
Counts as published in SMARTS; not a compliance determination · Details
SMARTS TMDL records Evidence: SMARTS-reported
0 records
TMDL records

Each label shows where a statement comes from. How to read the labels.

Overview and location

Reported facility location HUC12 watershed Corroborated receiving water 2026 Integrated Report waterbodies nearby

Open this facility on the statewide map

Reported location Evidence: facility-reported

Coordinates
38.665611, -121.429137
Precision
6 decimal places
Shared point
No
Matches application record
same

Facility location as reported by the discharger in SMARTS; not a discharge point or outfall.

Facility address
5400 Raley Blvd, Sacramento 95838
Regional Water Board
5S — Central Valley (Sacramento)

HUC12 watershed Evidence: spatial

  • Lower Steelhead Creek HUC12 180201110303

The facility's reported location lies within this HUC12 watershed (spatial derivation); it is not a discharge location.

Permits and applications Evidence: SMARTS record

Current permit record

Permit type
Industrial
Application type
Notice of Intent (WDID code I)
Status
Terminated
Operator
Jensen Precast
Primary industry (SIC)
3272-Concrete Products, Except Block and Brick
Application ID
200897
NOI processed
Feb 18, 2003
Termination effective
Oct 15, 2024
Last certified
May 09, 2023
Facility size
12 Acres

Retrieved from SMARTS Oct 20, 2026. Verify against SMARTS before relying on it.

Permit history

Storm water applications for this WDID, newest first
ApplicationTypeStatusProcessedTerminatedCertified
200897 IndustrialTerminatedFeb 18, 2003 Oct 15, 2024May 09, 2023

Every storm water application SMARTS records for this WDID, newest first (1).

Receiving water

Reported by the facility Evidence: facility-reported
Sacramento River
Discharges directly / indirectly
Y / N (as answered in the permit application)

Evidence: not confirmed Evidence: candidate, awaiting review Awaiting review

Receiving-water text as reported by the discharger in SMARTS; no waterbody identification has been confirmed.

Why it is not confirmed (1)
  • C1 name is only a prefix of official names

7 official waterbodies share this name; none is assigned without review.

Impaired waters and TMDLs

Two kinds of information, kept apart: 2026 Integrated Report waterbodies near the reported location (geographic proximity only), and TMDL records that SMARTS lists for this facility. Neither establishes where the facility discharges; see Receiving water for the facility's own statement.

Nearby waterbodies Evidence: geographic proximity

Spatial proximity only; discharge pathway not established. Being near a waterbody does not mean the facility discharges to it.

Nearest 2026 Integrated Report waterbodies
Waterbody (2026 Integrated Report)Distance2026 303(d) listAppendix A decisions
Magpie Creek CAR5192100020110819170251528 m not listed0

Waterbodies within 1.0 km of the reported facility location. Method proximity/1.

SMARTS TMDL records Evidence: SMARTS-reported

No TMDL records for this facility in the SMARTS TMDL export.

Reported monitoring results Evidence: facility-reported

Numeric Action Level (NAL) screening is being independently validated and is not shown. Nothing on this page states whether a result exceeded a NAL.

969 distinct measurements across 21 parameters, most recent sample Apr 04, 2024.

By reporting year

Distinct results by reporting year
Reporting year (July–June)Distinct resultsParametersWith several versionsFirst sampleLast sample
20231212 0 Apr 04, 2024Apr 04, 2024
202210313 0 Dec 01, 2022Feb 24, 2023
20217813 0 Nov 09, 2021Mar 15, 2022
20207012 0 Dec 17, 2020Feb 02, 2021
20194512 0 Dec 18, 2019Jan 19, 2020
20188412 0 Jan 15, 2019Feb 25, 2019
20179813 0 Nov 15, 2017Mar 13, 2018
201618113 0 Oct 14, 2016Feb 16, 2017
201529813 0 Nov 02, 2015Apr 22, 2016

By parameter

Distinct results by parameter
ParameterUnitsMeasurementsBelow detectionFirst sampleLast sampleResults
pHSU77 0Nov 02, 2015Apr 04, 2024 Results
Total Suspended Solids (TSS)mg/L77 2Nov 02, 2015Apr 04, 2024 Results
Chemical Oxygen Demand (COD)mg/L75 6Nov 02, 2015Apr 04, 2024 Results
Oil and Greasemg/L75 35Nov 02, 2015Apr 04, 2024 Results
Biochemical Oxygen Demand (BOD) (5-day @ 20 Deg. C)mg/L73 17Nov 02, 2015Apr 04, 2024 Results
Aluminum, Totalmg/L67 5Nov 02, 2015Apr 04, 2024 Results
Copper, Totalmg/L67 20Nov 02, 2015Apr 04, 2024 Results
Iron, Totalmg/L67 0Nov 02, 2015Apr 04, 2024 Results
Mercury, Totalug/L67 52Nov 02, 2015Apr 04, 2024 Results
Zinc, Totalmg/L67 9Nov 02, 2015Apr 04, 2024 Results
Cadmium, Totalmg/L66 62Nov 02, 2015Apr 04, 2024 Results
Lead, Totalmg/L66 38Nov 02, 2015Apr 04, 2024 Results
Show 9 more parameters
More parameters
ParameterUnitsMeasurementsBelow detectionFirst sampleLast sampleResults
Electrical Conductivity @ 25 Deg. Cumhos/cm52 0Nov 02, 2015Feb 24, 2023 Results
Aluminum, Total Recoverablemg/L10 0Dec 18, 2019Mar 15, 2022 Results
Cadmium, Total Recoverablemg/L10 10Dec 18, 2019Mar 15, 2022 Results
Copper, Total Recoverablemg/L10 4Dec 18, 2019Mar 15, 2022 Results
Iron, Total Recoverablemg/L10 0Dec 18, 2019Mar 15, 2022 Results
Lead, Total Recoverablemg/L10 4Dec 18, 2019Mar 15, 2022 Results
Mercury, Total Recoverablemg/L10 7Dec 18, 2019Mar 15, 2022 Results
Zinc, Total Recoverablemg/L10 2Dec 18, 2019Mar 15, 2022 Results
BOD5 @ 20 Deg. C, Percent Removalmg/L3 0Dec 18, 2019Jan 19, 2020 Results

All results (969 distinct rows)

Reported monitoring results, newest first
Sample dateParameterResultUnitsLocation typeEventMethodReportVersions
Apr 04, 2024 Aluminum, Total .622 mg/L Effluent Qualifying Storm Event E200.7 1286956
Apr 04, 2024 Biochemical Oxygen Demand (BOD) (5-day @ 20 Deg. C) ND mg/L Effluent Qualifying Storm Event A5210B 1286956
Apr 04, 2024 Cadmium, Total ND mg/L Effluent Qualifying Storm Event EPA 200.7 1286956
Apr 04, 2024 Chemical Oxygen Demand (COD) 42 mg/L Effluent Qualifying Storm Event A5220C 1286956
Apr 04, 2024 Copper, Total .00572 mg/L Effluent Qualifying Storm Event E200.7 1286956
Apr 04, 2024 Iron, Total .575 mg/L Effluent Qualifying Storm Event E200.7 1286956
Apr 04, 2024 Lead, Total .0005 mg/L Effluent Qualifying Storm Event E200.9 1286956
Apr 04, 2024 Mercury, Total ND ug/L Effluent Qualifying Storm Event E245.1 1286956
Apr 04, 2024 Oil and Grease 1.2 mg/L Effluent Qualifying Storm Event E1664B 1286956
Apr 04, 2024 pH 8.86 SU Effluent Qualifying Storm Event pH_Field 1286956
Apr 04, 2024 Total Suspended Solids (TSS) 18 mg/L Effluent Qualifying Storm Event A2540D 1286956
Apr 04, 2024 Zinc, Total .0159 mg/L Effluent Qualifying Storm Event E200.7 1286956
Feb 24, 2023 Aluminum, Total .61 mg/L Effluent Qualifying Storm Event E200.8 1230065
Feb 24, 2023 Aluminum, Total .61 mg/L Effluent Qualifying Storm Event E200.7 1266623
Feb 24, 2023 Biochemical Oxygen Demand (BOD) (5-day @ 20 Deg. C) 5.4 mg/L Effluent Qualifying Storm Event A5210B 1230065
Feb 24, 2023 Biochemical Oxygen Demand (BOD) (5-day @ 20 Deg. C) 5.4 mg/L Effluent Qualifying Storm Event A5210B 1266623
Feb 24, 2023 Cadmium, Total ND mg/L Effluent Qualifying Storm Event E200.8 1230065
Feb 24, 2023 Cadmium, Total ND mg/L Effluent Qualifying Storm Event EPA 200.7 1266623
Feb 24, 2023 Chemical Oxygen Demand (COD) 32 mg/L Effluent Qualifying Storm Event A5220C 1230065
Feb 24, 2023 Chemical Oxygen Demand (COD) 32 mg/L Effluent Qualifying Storm Event A5220C 1266623
Feb 24, 2023 Copper, Total .0056 mg/L Effluent Qualifying Storm Event E200.8 1230065
Feb 24, 2023 Copper, Total .0056 mg/L Effluent Qualifying Storm Event E200.7 1266623
Feb 24, 2023 Electrical Conductivity @ 25 Deg. C 1486 umhos/cm Effluent Qualifying Storm Event GRAB 1230065
Feb 24, 2023 Electrical Conductivity @ 25 Deg. C 1486 umhos/cm Effluent Qualifying Storm Event A2510B 1266623
Feb 24, 2023 Iron, Total 2.4 mg/L Effluent Qualifying Storm Event E200.7 1230065
Feb 24, 2023 Iron, Total 2.4 mg/L Effluent Qualifying Storm Event E200.7 1266623
Feb 24, 2023 Lead, Total .00074 mg/L Effluent Qualifying Storm Event E200.8 1230065
Feb 24, 2023 Lead, Total .00074 mg/L Effluent Qualifying Storm Event E200.9 1266623
Feb 24, 2023 Mercury, Total ND ug/L Effluent Qualifying Storm Event E245.1 1230065
Feb 24, 2023 Mercury, Total ND ug/L Effluent Qualifying Storm Event E245.1 1266623
Feb 24, 2023 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664B 1230065
Feb 24, 2023 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664B 1266623
Feb 24, 2023 pH 9.04 SU Effluent Qualifying Storm Event pH_Field 1230065
Feb 24, 2023 pH 9.04 SU Effluent Qualifying Storm Event pH_Field 1266623
Feb 24, 2023 Total Suspended Solids (TSS) 94 mg/L Effluent Qualifying Storm Event A2540D 1230065
Feb 24, 2023 Total Suspended Solids (TSS) 94 mg/L Effluent Qualifying Storm Event A2540D 1266623
Feb 24, 2023 Zinc, Total .015 mg/L Effluent Qualifying Storm Event E200.8 1230065
Feb 24, 2023 Zinc, Total .015 mg/L Effluent Qualifying Storm Event E200.7 1266623
Feb 03, 2023 Aluminum, Total .535 mg/L Effluent Qualifying Storm Event E200.7 1229105
Feb 03, 2023 Aluminum, Total .535 mg/L Effluent Qualifying Storm Event E200.7 1266622
Feb 03, 2023 Biochemical Oxygen Demand (BOD) (5-day @ 20 Deg. C) ND mg/L Effluent Qualifying Storm Event A5210B 1229105
Feb 03, 2023 Biochemical Oxygen Demand (BOD) (5-day @ 20 Deg. C) ND mg/L Effluent Qualifying Storm Event A5210B 1266622
Feb 03, 2023 Cadmium, Total ND mg/L Effluent Qualifying Storm Event EPA 200.7 1229105
Feb 03, 2023 Cadmium, Total ND mg/L Effluent Qualifying Storm Event EPA 200.7 1266622
Feb 03, 2023 Chemical Oxygen Demand (COD) 28 mg/L Effluent Qualifying Storm Event A5220C 1229105
Feb 03, 2023 Chemical Oxygen Demand (COD) 28 mg/L Effluent Qualifying Storm Event A5220C 1266622
Feb 03, 2023 Copper, Total .00372 mg/L Effluent Qualifying Storm Event E200.7 1229105
Feb 03, 2023 Copper, Total .00372 mg/L Effluent Qualifying Storm Event E200.7 1266622
Feb 03, 2023 Electrical Conductivity @ 25 Deg. C 347.2 umhos/cm Effluent Qualifying Storm Event GRAB 1229105
Feb 03, 2023 Electrical Conductivity @ 25 Deg. C 347.2 umhos/cm Effluent Qualifying Storm Event A2510B 1266622

Results are shown exactly as reported by the discharger. Identical rows repeated in the State's export are shown once. Where the export contains different versions of the same sample and parameter, each version is listed and flagged. Details.

Compliance and enforcement records Evidence: SMARTS record

These are records as the State Water Board publishes them in SMARTS, with the source's own types and statuses. They are not a compliance determination or rating. A record listed here is not proof of a violation beyond what the source states, and the absence of records does not establish compliance.

Compliance and enforcement records by type
Record typeRecordsAs publishedDatesRetrievedList
Violations8 8 Violation · 0 Potential (preliminary) · 0 Dismissed Jul 01, 2003 – Jul 15, 2025 Oct 21, 2026 All violations
Enforcement actions10 9 issued · 0 draft · 1 withdrawn, rescinded or superseded Aug 12, 2003 – Sep 10, 2025 Oct 21, 2026 All actions
Inspections3inspections, not findings Feb 28, 2014 – Oct 09, 2024 Oct 21, 2026 All inspections
Annual reports9certified reports (contents not shown) 2015 – 2023 Oct 21, 2026 All reports
Water-quality-based corrective action reports0reports, by parameter — Oct 21, 2026

Each record type is counted by its own SMARTS identifier. A violation and the enforcement action that cites it are two records in two lists; they are never added together.

Chronological record history (30 records, newest first)
Compliance and enforcement records, newest first
DateRecordIDType or purposeStatus as publishedDetail
Sep 10, 2025 Enforcement actions 463544 NOV (Notice of Violation) Historical
Aug 08, 2025 Enforcement actions 457174 NOV (Notice of Violation) Historical
Jul 15, 2025 Violations 892645 Late Report ViolationReport
Oct 09, 2024 Inspections 2065736 NOT PerformedNo Further Action
Aug 23, 2024 Annual reports 1244101 Annual report 2023 —
Sep 13, 2023 Inspections 2061779 B Type compliance PerformedAdditional Info Required
Jun 26, 2023 Annual reports 1190144 Annual report 2022 —
Jul 14, 2022 Annual reports 1113594 Annual report 2021 —
Feb 23, 2022 Enforcement actions 446110 NOV (Notice of Violation) Active
Jan 01, 2022 Violations 881346 Late Report ViolationReport
Jul 09, 2021 Annual reports 1069645 Annual report 2020 —
Jul 13, 2020 Annual reports 986974 Annual report 2019 —
Jul 12, 2019 Annual reports 954564 Annual report 2018 —
Jul 13, 2018 Annual reports 939982 Annual report 2017 —
Jul 14, 2017 Annual reports 879283 Annual report 2016 —
Jul 12, 2016 Annual reports 841443 Annual report 2015 —
Feb 28, 2014 Enforcement actions 415101 Verbal Communication Active
Feb 28, 2014 Inspections 2021724 B Type compliance —Follow-up Inspection Needed
Feb 28, 2014 Violations 853605 Deficient BMP Implementation ViolationInspection
Oct 14, 2010 Enforcement actions 403153 SEL (Staff Enforcement Letter) Historical
Oct 14, 2010 Violations 842896 Deficient BMP Implementation ViolationReport
Oct 23, 2009 Enforcement actions 401587 SEL (Staff Enforcement Letter) Historical
Jul 01, 2009 Violations 841382 Deficient BMP Implementation ViolationReport
May 01, 2008 Enforcement actions 347591 SEL (Staff Enforcement Letter) Active
Jul 01, 2007 Violations 766013 Deficient BMP Implementation ViolationStorm Water Discharge

Sources and provenance

Sources behind this page
InformationSourceRetrieved or published
Permit, location, receiving-water textSMARTS Industrial Application Specific DataOct 20, 2026
Permit historySMARTS Storm Water ApplicationsOct 20, 2026
Monitoring resultsSMARTS Industrial Parameter DataOct 20, 2026
Watershed Boundary Dataset HU2 GeoPackages 15, 16, 18 (WBDHU12)USGS2026-10-22
2026 California Integrated Report, Appendix A: 2026 303(d) List (final)SWRCB2026-10-22
Final_2026_Rivers_and_Streams + Final_2026_Lakes_and_Reservoirs (FeatureServer 0)SWRCB GIS2026-10-22
SMARTS TMDL requirementsSMARTS2026-10-21

Relationships computed 2026-10-22 with methods facility_huc12/1, proximity/1, receiving_water/2, tmdl_reference/1, waterbody_huc12_ovl/1, waterbody_huc12_pub/1; proximity threshold 1.0 km.

How to read the evidence labels

Records are shown as published and are not compliance determinations. How geographic context is derived.