California State Prison Solano

Active WDID 5S48I004100 Vacaville, Solano County Region 5S · Central Valley (Sacramento)

At a glance

Permit Evidence: SMARTS record
Active Industrial
Notice of Intent (WDID code I) · Permits and applications
Location Evidence: facility-reported
Vacaville, Solano County
Region 5S · Central Valley (Sacramento) · Location · Statewide map
Receiving water
Tributary Ditch to Union Creek (as reported by the facility)
Evidence: not confirmed Details
Identified receiving water on the 2026 303(d) list
Not established
Shown only when the reported receiving water is identified and corroborated.
2026 Integrated Report waters within 1.0 km Evidence: geographic proximity
1 waterbody; 0 on the 2026 303(d) list
Proximity only; not a discharge pathway · Nearby waterbodies
Monitoring results Evidence: facility-reported
364 distinct results, 3 reporting years (2015 to 2017)
Most recent sample Mar 22, 2018 · Monitoring
Compliance and enforcement records Evidence: SMARTS record
0 inspections · 11 violation records · 9 enforcement actions
Counts as published in SMARTS; not a compliance determination · Details
SMARTS TMDL records Evidence: SMARTS-reported
0 records
TMDL records

Each label shows where a statement comes from. How to read the labels.

Overview and location

Reported facility location HUC12 watershed Corroborated receiving water 2026 Integrated Report waterbodies nearby

Open this facility on the statewide map

Reported location Evidence: facility-reported

Coordinates
38.332448, -121.970469
Precision
6 decimal places
Shared point
No
Matches application record
same

Facility location as reported by the discharger in SMARTS; not a discharge point or outfall.

Facility address
2100 Peabody Rd, Vacaville 95687
Regional Water Board
5S — Central Valley (Sacramento)

HUC12 watershed Evidence: spatial

  • Barker Slough HUC12 180201630603

The facility's reported location lies within this HUC12 watershed (spatial derivation); it is not a discharge location.

Permits and applications Evidence: SMARTS record

Current permit record

Permit type
Industrial
Application type
Notice of Intent (WDID code I)
Status
Active
Operator
California State Prison Solano
Primary industry (SIC)
3499-Fabricated Metal Products, NEC
Secondary SIC
3272-Concrete Products, Except Block and Brick
Application ID
202025
NOI processed
Apr 06, 1992
Last certified
Jul 09, 2024
Facility size
222 Acres
Impervious area
77 %

Retrieved from SMARTS Oct 20, 2026. Verify against SMARTS before relying on it.

Permit history

Storm water applications for this WDID, newest first
ApplicationTypeStatusProcessedTerminatedCertified
202025 IndustrialActiveApr 06, 1992 —Jul 09, 2024

Every storm water application SMARTS records for this WDID, newest first (1).

Receiving water

Reported by the facility Evidence: facility-reported
Tributary Ditch to Union Creek
Discharges directly / indirectly
N / Y (as answered in the permit application)

Evidence: not confirmed Not matchable to a single waterbody

Receiving-water text as reported by the discharger in SMARTS; no waterbody identification has been confirmed.

Impaired waters and TMDLs

Two kinds of information, kept apart: 2026 Integrated Report waterbodies near the reported location (geographic proximity only), and TMDL records that SMARTS lists for this facility. Neither establishes where the facility discharges; see Receiving water for the facility's own statement.

Nearby waterbodies Evidence: geographic proximity

Spatial proximity only; discharge pathway not established. Being near a waterbody does not mean the facility discharges to it.

Nearest 2026 Integrated Report waterbodies
Waterbody (2026 Integrated Report)Distance2026 303(d) listAppendix A decisions
Old Alamo Creek (Solano County) CAR5111000020090108165859754 m not listed0

Waterbodies within 1.0 km of the reported facility location. Method proximity/1.

SMARTS TMDL records Evidence: SMARTS-reported

No TMDL records for this facility in the SMARTS TMDL export.

Reported monitoring results Evidence: facility-reported

Numeric Action Level (NAL) screening is being independently validated and is not shown. Nothing on this page states whether a result exceeded a NAL.

364 distinct measurements across 7 parameters, most recent sample Mar 22, 2018.

By reporting year

Distinct results by reporting year
Reporting year (July–June)Distinct resultsParametersWith several versionsFirst sampleLast sample
2017707 0 Mar 01, 2018Mar 22, 2018
20161267 0 Nov 20, 2016Mar 24, 2017
20151687 0 Dec 13, 2015Apr 27, 2016

By parameter

Distinct results by parameter
ParameterUnitsMeasurementsBelow detectionFirst sampleLast sampleResults
Aluminum, Totalmg/L52 10Dec 13, 2015Mar 22, 2018 Results
Iron, Totalmg/L52 10Dec 13, 2015Mar 22, 2018 Results
Nitrite Plus Nitrate (as N)mg/L52 4Dec 13, 2015Mar 22, 2018 Results
Oil and Greasemg/L52 52Dec 13, 2015Mar 22, 2018 Results
pHSU52 16Dec 13, 2015Mar 22, 2018 Results
Total Suspended Solids (TSS)mg/L52 11Dec 13, 2015Mar 22, 2018 Results
Zinc, Totalmg/L52 10Dec 13, 2015Mar 22, 2018 Results

All results (364 distinct rows)

Reported monitoring results, newest first
Sample dateParameterResultUnitsLocation typeEventMethodReportVersions
Mar 22, 2018 Aluminum, Total DNQ 3.14 mg/L Effluent Qualifying Storm Event A3113B 1002876
Mar 22, 2018 Aluminum, Total DNQ 2.33 mg/L Effluent Qualifying Storm Event A3113B 1002876
Mar 22, 2018 Aluminum, Total DNQ 14.4 mg/L Effluent Qualifying Storm Event A3113B 1002876
Mar 22, 2018 Aluminum, Total DNQ 21.3 mg/L Effluent Qualifying Storm Event A3113B 1002876
Mar 22, 2018 Aluminum, Total DNQ 21.7 mg/L Effluent Qualifying Storm Event A3113B 1002876
Mar 22, 2018 Iron, Total DNQ 3.71 mg/L Effluent Qualifying Storm Event A3111B 1002876
Mar 22, 2018 Iron, Total DNQ 2.91 mg/L Effluent Qualifying Storm Event A3111B 1002876
Mar 22, 2018 Iron, Total DNQ 12.4 mg/L Effluent Qualifying Storm Event A3111B 1002876
Mar 22, 2018 Iron, Total DNQ 26.3 mg/L Effluent Qualifying Storm Event A3111B 1002876
Mar 22, 2018 Iron, Total DNQ 30.7 mg/L Effluent Qualifying Storm Event A3111B 1002876
Mar 22, 2018 Nitrite Plus Nitrate (as N) 1.54 mg/L Effluent Qualifying Storm Event E300.0 1002876
Mar 22, 2018 Nitrite Plus Nitrate (as N) 1.23 mg/L Effluent Qualifying Storm Event E300.0 1002876
Mar 22, 2018 Nitrite Plus Nitrate (as N) 2.53 mg/L Effluent Qualifying Storm Event E300.0 1002876
Mar 22, 2018 Nitrite Plus Nitrate (as N) 2.28 mg/L Effluent Qualifying Storm Event E300.0 1002876
Mar 22, 2018 Nitrite Plus Nitrate (as N) 1.12 mg/L Effluent Qualifying Storm Event E300.0 1002876
Mar 22, 2018 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664A 1002876
Mar 22, 2018 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664A 1002876
Mar 22, 2018 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664A 1002876
Mar 22, 2018 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664A 1002876
Mar 22, 2018 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664A 1002876
Mar 22, 2018 pH 7.7 SU Effluent Qualifying Storm Event pH_Field 1002876
Mar 22, 2018 pH 7.6 SU Effluent Qualifying Storm Event pH_Field 1002876
Mar 22, 2018 pH 7.6 SU Effluent Qualifying Storm Event pH_Field 1002876
Mar 22, 2018 pH 7.3 SU Effluent Qualifying Storm Event pH_Field 1002876
Mar 22, 2018 pH 7.4 SU Effluent Qualifying Storm Event pH_Field 1002876
Mar 22, 2018 Total Suspended Solids (TSS) 39 mg/L Effluent Qualifying Storm Event A2540D 1002876
Mar 22, 2018 Total Suspended Solids (TSS) 30 mg/L Effluent Qualifying Storm Event A2540D 1002876
Mar 22, 2018 Total Suspended Solids (TSS) 159 mg/L Effluent Qualifying Storm Event A2540D 1002876
Mar 22, 2018 Total Suspended Solids (TSS) 284 mg/L Effluent Qualifying Storm Event A2540D 1002876
Mar 22, 2018 Total Suspended Solids (TSS) 241 mg/L Effluent Qualifying Storm Event A2540D 1002876
Mar 22, 2018 Zinc, Total DNQ .273 mg/L Effluent Qualifying Storm Event A3111B 1002876
Mar 22, 2018 Zinc, Total DNQ .318 mg/L Effluent Qualifying Storm Event A3111B 1002876
Mar 22, 2018 Zinc, Total DNQ .259 mg/L Effluent Qualifying Storm Event A3111B 1002876
Mar 22, 2018 Zinc, Total DNQ 182 mg/L Effluent Qualifying Storm Event A3111B 1002876
Mar 22, 2018 Zinc, Total DNQ .114 mg/L Effluent Qualifying Storm Event A3111B 1002876
Mar 01, 2018 Aluminum, Total DNQ .223 mg/L Effluent Qualifying Storm Event A3113B 994993
Mar 01, 2018 Aluminum, Total DNQ .14 mg/L Effluent Qualifying Storm Event A3113B 994993
Mar 01, 2018 Aluminum, Total DNQ .252 mg/L Effluent Qualifying Storm Event A3113B 994993
Mar 01, 2018 Aluminum, Total DNQ .652 mg/L Effluent Qualifying Storm Event A3113B 994993
Mar 01, 2018 Aluminum, Total DNQ 1.9 mg/L Effluent Qualifying Storm Event A3113B 994993
Mar 01, 2018 Iron, Total DNQ .472 mg/L Effluent Qualifying Storm Event A3111B 994993
Mar 01, 2018 Iron, Total DNQ .31 mg/L Effluent Qualifying Storm Event A3111B 994993
Mar 01, 2018 Iron, Total DNQ .294 mg/L Effluent Qualifying Storm Event A3111B 994993
Mar 01, 2018 Iron, Total DNQ 1.06 mg/L Effluent Qualifying Storm Event A3111B 994993
Mar 01, 2018 Iron, Total DNQ 2.67 mg/L Effluent Qualifying Storm Event A3111B 994993
Mar 01, 2018 Nitrite Plus Nitrate (as N) 2.61 mg/L Effluent Qualifying Storm Event E300.0 994993
Mar 01, 2018 Nitrite Plus Nitrate (as N) 2.19 mg/L Effluent Qualifying Storm Event E300.0 994993
Mar 01, 2018 Nitrite Plus Nitrate (as N) 9.45 mg/L Effluent Qualifying Storm Event E300.0 994993
Mar 01, 2018 Nitrite Plus Nitrate (as N) 3.81 mg/L Effluent Qualifying Storm Event E300.0 994993
Mar 01, 2018 Nitrite Plus Nitrate (as N) 1.57 mg/L Effluent Qualifying Storm Event E300.0 994993

Results are shown exactly as reported by the discharger. Identical rows repeated in the State's export are shown once. Where the export contains different versions of the same sample and parameter, each version is listed and flagged. Details.

Compliance and enforcement records Evidence: SMARTS record

These are records as the State Water Board publishes them in SMARTS, with the source's own types and statuses. They are not a compliance determination or rating. A record listed here is not proof of a violation beyond what the source states, and the absence of records does not establish compliance.

Compliance and enforcement records by type
Record typeRecordsAs publishedDatesRetrievedList
Violations11 11 Violation · 0 Potential (preliminary) · 0 Dismissed Mar 27, 2000 – Jan 01, 2019 Oct 21, 2026 All violations
Enforcement actions9 9 issued · 0 draft · 0 withdrawn, rescinded or superseded Mar 27, 2000 – Feb 13, 2019 Oct 21, 2026 All actions
Inspections0inspections, not findings — Oct 21, 2026
Annual reports11certified reports (contents not shown) 2015 – 2025 Oct 21, 2026 All reports
Water-quality-based corrective action reports0reports, by parameter — Oct 21, 2026

Each record type is counted by its own SMARTS identifier. A violation and the enforcement action that cites it are two records in two lists; they are never added together.

Chronological record history (31 records, newest first)
Compliance and enforcement records, newest first
DateRecordIDType or purposeStatus as publishedDetail
Mar 09, 2026 Annual reports 1335676 Annual report 2025 —
Apr 01, 2025 Annual reports 1294508 Annual report 2024 —
Jul 08, 2024 Annual reports 1243611 Annual report 2023 —
Oct 05, 2023 Annual reports 1189633 Annual report 2022 —
Jul 11, 2022 Annual reports 1113036 Annual report 2021 —
Jul 12, 2021 Annual reports 1069061 Annual report 2020 —
Jul 09, 2020 Annual reports 986347 Annual report 2019 —
Jul 12, 2019 Annual reports 953919 Annual report 2018 —
Feb 13, 2019 Enforcement actions 432976 NOV (Notice of Violation) Historical
Jan 01, 2019 Violations 869821 Late Report ViolationReport
Jul 10, 2018 Annual reports 939337 Annual report 2017 —
Feb 23, 2018 Enforcement actions 429220 NOV (Notice of Violation) Active
Jan 01, 2018 Violations 866322 Late Report ViolationReport
Jul 13, 2017 Annual reports 878601 Annual report 2016 —
Jul 07, 2016 Annual reports 847222 Annual report 2015 —
Nov 21, 2014 Enforcement actions 417202 13267 Letter/Order (Water Code section 13267 letter or order) Active
Aug 15, 2014 Enforcement actions 416516 1st NNC - AR (First Notice of Non-Compliance (annual report)) Historical
Jul 01, 2014 Violations 854865 Late Report ViolationReport
Jul 01, 2014 Violations 855425 Deficient BMP Implementation ViolationReport
Jul 01, 2013 Violations 855426 Deficient BMP Implementation ViolationReport
Jul 01, 2012 Violations 855427 Deficient BMP Implementation ViolationReport
Mar 23, 2012 Enforcement actions 408408 13267 Letter/Order (Water Code section 13267 letter or order) Historical
Jun 30, 2011 Violations 847711 Deficient BMP Implementation ViolationReport
Oct 23, 2009 Enforcement actions 401728 SEL (Staff Enforcement Letter) Historical
Jul 01, 2009 Violations 841568 Deficient BMP Implementation ViolationReport

Sources and provenance

Sources behind this page
InformationSourceRetrieved or published
Permit, location, receiving-water textSMARTS Industrial Application Specific DataOct 20, 2026
Permit historySMARTS Storm Water ApplicationsOct 20, 2026
Monitoring resultsSMARTS Industrial Parameter DataOct 20, 2026
Watershed Boundary Dataset HU2 GeoPackages 15, 16, 18 (WBDHU12)USGS2026-10-22
2026 California Integrated Report, Appendix A: 2026 303(d) List (final)SWRCB2026-10-22
Final_2026_Rivers_and_Streams + Final_2026_Lakes_and_Reservoirs (FeatureServer 0)SWRCB GIS2026-10-22
SMARTS TMDL requirementsSMARTS2026-10-21

Relationships computed 2026-10-22 with methods facility_huc12/1, proximity/1, receiving_water/2, tmdl_reference/1, waterbody_huc12_ovl/1, waterbody_huc12_pub/1; proximity threshold 1.0 km.

How to read the evidence labels

Records are shown as published and are not compliance determinations. How geographic context is derived.