Pacific Stone Design Inc

Active WDID 8 30I024368 Santa Ana, Orange County Region 8 · Santa Ana

At a glance

Permit Evidence: SMARTS record
Active Industrial
Notice of Intent (WDID code I) · Permits and applications
Location Evidence: facility-reported
Santa Ana, Orange County
Region 8 · Santa Ana · Location · Statewide map
Receiving water
Santa Ana River (as reported by the facility)
Evidence: candidate, awaiting review Details
Identified receiving water on the 2026 303(d) list
Not established
Shown only when the reported receiving water is identified and corroborated.
2026 Integrated Report waters within 1.0 km Evidence: geographic proximity
None
Monitoring results Evidence: facility-reported
8 distinct results, 2 reporting years (2018 to 2019)
Most recent sample Mar 16, 2020 · Monitoring
Compliance and enforcement records Evidence: SMARTS record
0 inspections · 0 violation records · 0 enforcement actions
Counts as published in SMARTS; not a compliance determination · Details
SMARTS TMDL records Evidence: SMARTS-reported
0 records
TMDL records

Each label shows where a statement comes from. How to read the labels.

Overview and location

Reported facility location HUC12 watershed Corroborated receiving water 2026 Integrated Report waterbodies nearby

Open this facility on the statewide map

Reported location Evidence: facility-reported

Coordinates
33.73743, -117.85292
Precision
5 decimal places
Shared point
2 permits report this exact point
Matches application record
same

Facility location as reported by the discharger in SMARTS; not a discharge point or outfall.

Facility address
1201 E Wakeham Ave, Santa Ana 92705
Regional Water Board
8 — Santa Ana

HUC12 watershed Evidence: spatial

  • Lower San Diego Creek HUC12 180702040103

The facility's reported location lies within this HUC12 watershed (spatial derivation); it is not a discharge location.

Permits and applications Evidence: SMARTS record

Current permit record

Permit type
Industrial
Application type
Notice of Intent (WDID code I)
Status
Active
Operator
Scott Sterling
Primary industry (SIC)
3272-Concrete Products, Except Block and Brick
Application ID
439817
NOI processed
Jul 22, 2013
Last certified
May 05, 2016
Facility size
44000 SqFt
Impervious area
10 %

Retrieved from SMARTS Oct 20, 2026. Verify against SMARTS before relying on it.

Permit history

Storm water applications for this WDID, newest first
ApplicationTypeStatusProcessedTerminatedCertified
439817 IndustrialActiveJul 22, 2013 —May 05, 2016

Every storm water application SMARTS records for this WDID, newest first (1).

Receiving water

Reported by the facility Evidence: facility-reported
Santa Ana River
Discharges directly / indirectly
N / Y (as answered in the permit application)

Evidence: not confirmed Evidence: candidate, awaiting review Awaiting review

Receiving-water text as reported by the discharger in SMARTS; no waterbody identification has been confirmed.

Why it is not confirmed (1)
  • C1 name is only a prefix of official names

6 official waterbodies share this name; none is assigned without review.

Impaired waters and TMDLs

Two kinds of information, kept apart: 2026 Integrated Report waterbodies near the reported location (geographic proximity only), and TMDL records that SMARTS lists for this facility. Neither establishes where the facility discharges; see Receiving water for the facility's own statement.

Nearby waterbodies Evidence: geographic proximity

Spatial proximity only; discharge pathway not established. Being near a waterbody does not mean the facility discharges to it.

No 2026 Integrated Report waterbody lies within the proximity threshold of the reported location.

SMARTS TMDL records Evidence: SMARTS-reported

No TMDL records for this facility in the SMARTS TMDL export.

Reported monitoring results Evidence: facility-reported

Numeric Action Level (NAL) screening is being independently validated and is not shown. Nothing on this page states whether a result exceeded a NAL.

8 distinct measurements across 4 parameters, most recent sample Mar 16, 2020.

By reporting year

Distinct results by reporting year
Reporting year (July–June)Distinct resultsParametersWith several versionsFirst sampleLast sample
201944 0 Mar 16, 2020Mar 16, 2020
201844 0 Jan 14, 2019Jan 14, 2019

By parameter

Distinct results by parameter
ParameterUnitsMeasurementsBelow detectionFirst sampleLast sampleResults
Iron, Totalmg/L2 1Jan 14, 2019Mar 16, 2020 Results
Oil and Greasemg/L2 2Jan 14, 2019Mar 16, 2020 Results
pHSU2 0Jan 14, 2019Mar 16, 2020 Results
Total Suspended Solids (TSS)mg/L2 1Jan 14, 2019Mar 16, 2020 Results

All results (8 distinct rows)

Reported monitoring results, newest first
Sample dateParameterResultUnitsLocation typeEventMethodReportVersions
Mar 16, 2020 Iron, Total .183 mg/L Effluent Qualifying Storm Event E200.7 1102616
Mar 16, 2020 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664A 1102616
Mar 16, 2020 pH 6.87 SU Effluent Qualifying Storm Event A4500HB 1102616
Mar 16, 2020 Total Suspended Solids (TSS) ND mg/L Effluent Qualifying Storm Event A2540D 1102616
Jan 14, 2019 Iron, Total ND mg/L Effluent Qualifying Storm Event E200.7 1035825
Jan 14, 2019 Oil and Grease ND mg/L Effluent Qualifying Storm Event E1664A 1035825
Jan 14, 2019 pH 7 SU Effluent Qualifying Storm Event pH_Field 1035825
Jan 14, 2019 Total Suspended Solids (TSS) 32 mg/L Effluent Qualifying Storm Event A2540D 1035825

Results are shown exactly as reported by the discharger. Identical rows repeated in the State's export are shown once. Where the export contains different versions of the same sample and parameter, each version is listed and flagged. Details.

Compliance and enforcement records Evidence: SMARTS record

These are records as the State Water Board publishes them in SMARTS, with the source's own types and statuses. They are not a compliance determination or rating. A record listed here is not proof of a violation beyond what the source states, and the absence of records does not establish compliance.

Compliance and enforcement records by type
Record typeRecordsAs publishedDatesRetrievedList
Violations0 0 Violation · 0 Potential (preliminary) · 0 Dismissed — Oct 21, 2026
Enforcement actions0 0 issued · 0 draft · 0 withdrawn, rescinded or superseded — Oct 21, 2026
Inspections0inspections, not findings — Oct 21, 2026
Annual reports11certified reports (contents not shown) 2015 – 2025 Oct 21, 2026 All reports
Water-quality-based corrective action reports0reports, by parameter — Oct 21, 2026

Each record type is counted by its own SMARTS identifier. A violation and the enforcement action that cites it are two records in two lists; they are never added together.

Chronological record history (11 records, newest first)
Compliance and enforcement records, newest first
DateRecordIDType or purposeStatus as publishedDetail
Jun 30, 2026 Annual reports 1338102 Annual report 2025 —
Jul 02, 2025 Annual reports 1297077 Annual report 2024 —
Jul 08, 2024 Annual reports 1246296 Annual report 2023 —
Jun 29, 2023 Annual reports 1192435 Annual report 2022 —
Jul 01, 2022 Annual reports 1116119 Annual report 2021 —
Jun 30, 2021 Annual reports 1064263 Annual report 2020 —
Jul 07, 2020 Annual reports 981237 Annual report 2019 —
Jun 24, 2019 Annual reports 957533 Annual report 2018 —
Jul 12, 2018 Annual reports 942972 Annual report 2017 —
Jul 12, 2017 Annual reports 882478 Annual report 2016 —
Jun 23, 2016 Annual reports 846655 Annual report 2015 —

Sources and provenance

Sources behind this page
InformationSourceRetrieved or published
Permit, location, receiving-water textSMARTS Industrial Application Specific DataOct 20, 2026
Permit historySMARTS Storm Water ApplicationsOct 20, 2026
Monitoring resultsSMARTS Industrial Parameter DataOct 20, 2026
Watershed Boundary Dataset HU2 GeoPackages 15, 16, 18 (WBDHU12)USGS2026-10-22
2026 California Integrated Report, Appendix A: 2026 303(d) List (final)SWRCB2026-10-22
Final_2026_Rivers_and_Streams + Final_2026_Lakes_and_Reservoirs (FeatureServer 0)SWRCB GIS2026-10-22
SMARTS TMDL requirementsSMARTS2026-10-21

Relationships computed 2026-10-22 with methods facility_huc12/1, proximity/1, receiving_water/2, tmdl_reference/1, waterbody_huc12_ovl/1, waterbody_huc12_pub/1; proximity threshold 1.0 km.

How to read the evidence labels

Records are shown as published and are not compliance determinations. How geographic context is derived.