← Facilities

Industrial stormwater facility

Benicia Fabrication Machine

2 48I021028 · Notice of Intent · Benicia, Solano

Official record — State Water Resources Control Board, Industrial General Permit

Official

Facility record

Facility name
Benicia Fabrication Machine
WDID
2 48I021028
Application type
Notice of Intent
City
Benicia
County
Solano
ZIP
94510
Primary SIC code
3443
SIC description
Fabricated Plate Work (Boiler Shops)
Date active
2007-07-24
Regional Water Board
Regional Board 2 - San Francisco Bay Region

Hydrologic

Geographic context

Official facility coordinate plotted against the official 2026 impaired-water geometry.

Official facility point
38.07854, -122.13614
HUC12 subwatershed
American Canyon-Frontal Suisun Bay Estuaries
HUC12 code
180500010109
Impaired-water associations (derived)
2
Loading map…

303(d) context

Associated impaired waters

Grouped by derived geographic association class.

Derived

Same impaired-water subwatershed

2 waterbodies
Carquinez Strait

Estuary · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (10) Chlordane, DDT (Dichlorodiphenyltrichloroethane), Dieldrin, Dioxin compounds (including 2,3,7,8-TCDD), Furan Compounds, Invasive Species +4 more

Distance

Confidence low

Fact sheet

Suisun Marsh Wetlands

Wetland, Tidal · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (5) Mercury, Nutrients, Organic Enrichment/Low Dissolved Oxygen, Salinity/TDS/Chlorides, Temperature, water

Distance

Confidence low

Fact sheet

Associations are calculated from official facility coordinates, USGS HUC12 boundaries, and official 2026 impaired-water geometry. They do not establish a discharge connection or causation.

TMDL requirements

Water Board-stated TMDL waste load allocations applied to this industrial permit in SMARTS.

Official record — SMARTS TMDL dataset, State Water Board

No SMARTS TMDL requirement is recorded for this WDID. In the statewide TMDL export only permits in Regions 4, 8 and 9 currently carry industrial TMDL requirements, so an absence here is not a statement that the facility discharges to an unimpaired water.

Official monitoring

SMARTS monitoring

Self-reported industrial stormwater sampling results as submitted by the discharger to SMARTS.

Official record — SMARTS parameter data, State Water Board
Reported results
507
Sample events
65
Distinct parameters
23
Reporting years
2015 – 2025
First sample
2015-11-09
Latest sample
2026-04-24
Source regional dataset
Region 2 - San Francisco Bay
Source retrieved
Aug 21, 2026

Official SMARTS public reports

Parameters reported

Reported results over time

Loading reported results…

Most recent reported results

Latest 25 of 507
Sample dateLocationParameterResultUnitsEvent
2026-04-24#1 underground pipeAluminum.1mg/LQualifying Storm Event
2026-04-24#1 underground pipeCopper.00446mg/LQualifying Storm Event
2026-04-24#1 underground pipeIron.23mg/LQualifying Storm Event
2026-04-24#1 underground pipeNitrate/Nitrite (Nitrite + Nitrate as N).075mg/LQualifying Storm Event
2026-04-24#1 underground pipeOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2026-04-24#1 underground pipepH7SUQualifying Storm Event
2026-04-24#1 underground pipeTotal Suspended Solids (TSS)6.4mg/LQualifying Storm Event
2026-04-24#1 underground pipeZinc.12mg/LQualifying Storm Event
2025-11-13#2 underground pipeAluminum.0346mg/LQualifying Storm Event
2025-11-13#2 underground pipeCopper.0028mg/LQualifying Storm Event
2025-11-13#2 underground pipeIron.0626mg/LQualifying Storm Event
2025-11-13#2 underground pipeNitrate/Nitrite (Nitrite + Nitrate as N).096mg/LQualifying Storm Event
2025-11-13#2 underground pipeOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2025-11-13#2 underground pipepH7SUQualifying Storm Event
2025-11-13#2 underground pipeTotal Suspended Solids (TSS)1.8mg/LQualifying Storm Event
2025-11-13#2 underground pipeZinc.0685mg/LQualifying Storm Event
2025-03-27#1 underground pipeAluminum.16mg/LQualifying Storm Event
2025-03-27#1 underground pipeCopper.01mg/LQualifying Storm Event
2025-03-27#1 underground pipeIron.27mg/LQualifying Storm Event
2025-03-27#1 underground pipeNitrate/Nitrite (Nitrite + Nitrate as N).53mg/LQualifying Storm Event
2025-03-27#1 underground pipeOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2025-03-27#1 underground pipepH7.14SUQualifying Storm Event
2025-03-27#1 underground pipeTotal Suspended Solids (TSS)10.4mg/LQualifying Storm Event
2025-03-27#1 underground pipeZinc.23mg/LQualifying Storm Event
2025-01-03#1 underground pipeAluminum.11mg/LQualifying Storm Event

Monitoring rows are official self-reported SMARTS submissions, joined to this facility by WDID. California Stormwater Intelligence does not restate, correct, average or evaluate reported values, and no benchmark comparison or violation determination is made.

YDOS-derived

Numeric Action Level comparison

Reported SMARTS analytical results compared against the Numeric Action Levels of the Industrial General Permit version in effect for each reporting year (July 1 – June 30).

Derived
Reporting years evaluated
10
Years with an NAL exceedance
4
Most recent evaluated year
RY 2025
Ruleset
igp_nal_ruleset_v1 / igp_nal_v1
ParameterNAL typeCalculated valueNALResultSamples usedMethod

Aluminum, Total

aluminum_total

Annual0.067 mg/L0.75 mg/LAt or below NALAnnual average of 2 eligible result(s) compared with the annual NAL.0.09× threshold2 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Copper, Total

copper_total

Annual0.004 mg/L0.033 mg/LAt or below NALAnnual average of 2 eligible result(s) compared with the annual NAL.0.11× threshold2 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Iron, Total

iron_total

Annual0.146 mg/L1 mg/LAt or below NALAnnual average of 2 eligible result(s) compared with the annual NAL.0.15× threshold2 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Nitrite Plus Nitrate (as N)

nitrate_nitrite_n

Annual0.086 mg/L as N0.68 mg/L as NAt or below NALAnnual average of 2 eligible result(s) compared with the annual NAL.0.13× threshold2 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Oil and Grease

oil_grease

Instantaneous maximum0 samples above25 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.2 eligible2 non-detect as zerocount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

pH

ph

Instantaneous maximum0 samples above6 – 9 pH unitsWithin NAL rangeNo eligible result in this reporting year was outside the instantaneous maximum NAL.2 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Total Suspended Solids (TSS)

tss

Instantaneous maximum0 samples above400 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.2 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Zinc, Total

zinc_total

Annual0.094 mg/L0.26 mg/LAt or below NALAnnual average of 2 eligible result(s) compared with the annual NAL.0.36× threshold2 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

An NAL exceedance is a permit-defined condition that triggers Exceedance Response Actions under the Industrial General Permit. It is not a violation, an enforcement action, or a Water Board compliance determination. Annual values use the arithmetic average of eligible results with non-detects treated as zero; instantaneous maximum NALs (total suspended solids, oil and grease, pH) are exceeded when two or more eligible results in a reporting year fall outside the level. Rules transcribed from 2014-0057-DWQ as amended by 2015-0122-DWQ (effective 2015-07-01, superseded 2020-06-30); 2014-0057-DWQ as amended by 2018-0028-DWQ (effective 2020-07-01).

Provenance

Source & provenance

Source agency
California State Water Resources Control Board
Source dataset
Industrial General Permit — permitted facilities (statewide GIS layer)
WDID
2 48I021028
Source feature ID
10581
Application type
Notice of Intent
Regional board derivation
WDID region prefix
Geometry status
valid
Last successful facility import
Aug 21, 2026, 1:57 AM UTC

Official IGP permitted facilities feature layer