← Facilities

Industrial stormwater facility

Bobrick Washroom Equipment

4 19I026307 · Notice of Intent · North Hollywood, Los Angeles

Official record — State Water Resources Control Board, Industrial General Permit

Official

Facility record

Facility name
Bobrick Washroom Equipment
WDID
4 19I026307
Application type
Notice of Intent
City
North Hollywood
County
Los Angeles
ZIP
91605
Primary SIC code
2541
SIC description
Wood Office and Store Fixtures, Partitions, Shelving, and Lockers
Date active
2015-11-25
Regional Water Board
Regional Board 4 - Los Angeles Region

Hydrologic

Geographic context

Official facility coordinate plotted against the official 2026 impaired-water geometry.

Official facility point
34.19637, -118.37905
HUC12 subwatershed
Tujunga Wash-Los Angeles River
HUC12 code
180701050208
Impaired-water associations (derived)
6
Loading map…

303(d) context

Associated impaired waters

Grouped by derived geographic association class.

Derived

Same impaired-water subwatershed

6 waterbodies
Balboa Lake

Lake & Reservoir · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (3) Oxygen, Dissolved, Temperature, water, Toxicity

Distance

Confidence low

Fact sheet

Los Angeles River Reach 3 (Figueroa St. to Riverside Dr.)

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (5) Copper, Indicator Bacteria, Nutrients (Algae), Toxicity, Trash

Distance

Confidence low

Fact sheet

Los Angeles River Reach 4 (Sepulveda Dr. to Sepulveda Dam)

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (4) Indicator Bacteria, Nutrients (Algae), Toxicity, Trash

Distance

Confidence low

Fact sheet

Los Angeles River Reach 6 (Above Sepulveda Flood Control Basin)

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (9) Chlordane, Chloride, Copper, Indicator Bacteria, Selenium, Sulfates +3 more

Distance

Confidence low

Fact sheet

Tujunga Wash (LA River to Hansen Dam)

River & Stream · Integrated Report category 4a · TMDL approved by USEPA

Listed pollutants / stressors (4) Ammonia, Copper, Indicator Bacteria, Trash

Distance

Confidence low

Fact sheet

Wildlife Lake

Lake & Reservoir · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (1) Oxygen, Dissolved

Distance

Confidence low

Fact sheet

Associations are calculated from official facility coordinates, USGS HUC12 boundaries, and official 2026 impaired-water geometry. They do not establish a discharge connection or causation.

TMDL requirements

Water Board-stated TMDL waste load allocations applied to this industrial permit in SMARTS.

Official record — SMARTS TMDL dataset, State Water Board

No SMARTS TMDL requirement is recorded for this WDID. In the statewide TMDL export only permits in Regions 4, 8 and 9 currently carry industrial TMDL requirements, so an absence here is not a statement that the facility discharges to an unimpaired water.

Official monitoring

SMARTS monitoring

Self-reported industrial stormwater sampling results as submitted by the discharger to SMARTS.

Official record — SMARTS parameter data, State Water Board
Reported results
57
Sample events
19
Distinct parameters
3
Reporting years
2015 – 2025
First sample
2016-03-11
Latest sample
2026-02-16
Source regional dataset
Region 4 - Los Angeles
Source retrieved
Aug 21, 2026

Official SMARTS public reports

Parameters reported

Reported results over time

Loading reported results…

Most recent reported results

Latest 25 of 57
Sample dateLocationParameterResultUnitsEvent
2026-02-16Service Entrance DrivewayOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2026-02-16Service Entrance DrivewaypH8.4SUQualifying Storm Event
2026-02-16Service Entrance DrivewayTotal Suspended Solids (TSS)ND (non-detect / est.)mg/LQualifying Storm Event
2025-11-20Service Entrance DrivewayOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2025-11-20Service Entrance DrivewaypH6.8SUQualifying Storm Event
2025-11-20Service Entrance DrivewayTotal Suspended Solids (TSS)ND (non-detect / est.)mg/LQualifying Storm Event
2024-02-01Service Entrance DrivewayOil and Grease< 1(non-detect / est.)mg/LQualifying Storm Event
2024-02-01Service Entrance DrivewaypH9.2SUQualifying Storm Event
2024-02-01Service Entrance DrivewayTotal Suspended Solids (TSS)13mg/LQualifying Storm Event
2024-01-03Service Entrance DrivewayOil and Grease4.7mg/LQualifying Storm Event
2024-01-03Service Entrance DrivewaypH9.7SUQualifying Storm Event
2024-01-03Service Entrance DrivewayTotal Suspended Solids (TSS)< 5(non-detect / est.)mg/LQualifying Storm Event
2023-03-10Service Entrance DrivewayOil and Grease4.1mg/LQualifying Storm Event
2023-03-10Service Entrance DrivewaypH9.8SUQualifying Storm Event
2023-03-10Service Entrance DrivewayTotal Suspended Solids (TSS)9mg/LQualifying Storm Event
2023-01-09Service Entrance DrivewayOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2023-01-09Service Entrance DrivewaypH9.8SUQualifying Storm Event
2023-01-09Service Entrance DrivewayTotal Suspended Solids (TSS)ND (non-detect / est.)mg/LQualifying Storm Event
2022-03-28Service Entrance DrivewayOil and Grease1mg/LQualifying Storm Event
2022-03-28Service Entrance DrivewaypH7.61SUQualifying Storm Event
2022-03-28Service Entrance DrivewayTotal Suspended Solids (TSS)ND (non-detect / est.)mg/LQualifying Storm Event
2021-12-15Service Entrance DrivewayOil and Grease3mg/LQualifying Storm Event
2021-12-15Service Entrance DrivewaypH9.87SUQualifying Storm Event
2021-12-15Service Entrance DrivewayTotal Suspended Solids (TSS)9mg/LQualifying Storm Event
2021-11-04Service Entrance DrivewayOil and Grease62mg/LQualifying Storm Event

Monitoring rows are official self-reported SMARTS submissions, joined to this facility by WDID. California Stormwater Intelligence does not restate, correct, average or evaluate reported values, and no benchmark comparison or violation determination is made.

YDOS-derived

Numeric Action Level comparison

Reported SMARTS analytical results compared against the Numeric Action Levels of the Industrial General Permit version in effect for each reporting year (July 1 – June 30).

Derived
Reporting years evaluated
9
Years with an NAL exceedance
4
Most recent evaluated year
RY 2025
Ruleset
igp_nal_ruleset_v1 / igp_nal_v1
ParameterNAL typeCalculated valueNALResultSamples usedMethod

Oil and Grease

oil_grease

Instantaneous maximum0 samples above25 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.2 eligible2 non-detect as zerocount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

pH

ph

Instantaneous maximum0 samples above6 – 9 pH unitsWithin NAL rangeNo eligible result in this reporting year was outside the instantaneous maximum NAL.2 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Total Suspended Solids (TSS)

tss

Instantaneous maximum0 samples above400 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.2 eligible2 non-detect as zerocount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

An NAL exceedance is a permit-defined condition that triggers Exceedance Response Actions under the Industrial General Permit. It is not a violation, an enforcement action, or a Water Board compliance determination. Annual values use the arithmetic average of eligible results with non-detects treated as zero; instantaneous maximum NALs (total suspended solids, oil and grease, pH) are exceeded when two or more eligible results in a reporting year fall outside the level. Rules transcribed from 2014-0057-DWQ as amended by 2015-0122-DWQ (effective 2015-07-01, superseded 2020-06-30); 2014-0057-DWQ as amended by 2018-0028-DWQ (effective 2020-07-01).

Provenance

Source & provenance

Source agency
California State Water Resources Control Board
Source dataset
Industrial General Permit — permitted facilities (statewide GIS layer)
WDID
4 19I026307
Source feature ID
12591
Application type
Notice of Intent
Regional board derivation
WDID region prefix
Geometry status
valid
Last successful facility import
Aug 21, 2026, 1:57 AM UTC

Official IGP permitted facilities feature layer