← Facilities

Industrial stormwater facility

Bruce Metal Salvage Inc

8 30MR000029 · Region 8 - Scrap Metal Permit · Santa Ana, Orange

Official record — State Water Resources Control Board, Industrial General Permit

Official

Facility record

Facility name
Bruce Metal Salvage Inc
WDID
8 30MR000029
Application type
Region 8 - Scrap Metal Permit
City
Santa Ana
County
Orange
ZIP
92701
Primary SIC code
5093
SIC description
Scrap and Waste Materials
Date active
2012-05-25
Regional Water Board
Regional Board 8 - Santa Ana Region

Hydrologic

Geographic context

Official facility coordinate plotted against the official 2026 impaired-water geometry.

Official facility point
33.74970, -117.85825
HUC12 subwatershed
Lower San Diego Creek
HUC12 code
180702040103
Impaired-water associations (derived)
6
Loading map…

303(d) context

Associated impaired waters

Grouped by derived geographic association class.

Derived

Same impaired-water subwatershed

6 waterbodies
Bonita Creek

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (2) Benthic Community Effects, Toxicity

Distance

Confidence low

Fact sheet

Newport Bay, Upper (Ecological Reserve)

Estuary · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (8) Chlordane, Copper, DDT (Dichlorodiphenyltrichloroethane), Indicator Bacteria, Nutrients, PCBs (Polychlorinated biphenyls) +2 more

Distance

Confidence low

Fact sheet

Peters Canyon Wash (Orange County)

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (9) Benthic Community Effects, Copper, DDT (Dichlorodiphenyltrichloroethane), Indicator Bacteria, Malathion, pH +3 more

Distance

Confidence low

Fact sheet

San Diego Creek Reach 1

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (12) Benthic Community Effects, Bifenthrin, DDT (Dichlorodiphenyltrichloroethane), Indicator Bacteria, Malathion, Nitrogen +6 more

Distance

Confidence low

Fact sheet

Sand Canyon Reservoir (Orange County)

Lake & Reservoir · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (1) pH

Distance

Confidence low

Fact sheet

Siphon Reservoir (Orange County)

Lake & Reservoir · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (1) pH

Distance

Confidence low

Fact sheet

Associations are calculated from official facility coordinates, USGS HUC12 boundaries, and official 2026 impaired-water geometry. They do not establish a discharge connection or causation.

TMDL requirements

Water Board-stated TMDL waste load allocations applied to this industrial permit in SMARTS.

Official record — SMARTS TMDL dataset, State Water Board

No SMARTS TMDL requirement is recorded for this WDID. In the statewide TMDL export only permits in Regions 4, 8 and 9 currently carry industrial TMDL requirements, so an absence here is not a statement that the facility discharges to an unimpaired water.

Official monitoring

SMARTS monitoring

Self-reported industrial stormwater sampling results as submitted by the discharger to SMARTS.

Official record — SMARTS parameter data, State Water Board
Reported results
1,335
Sample events
89
Distinct parameters
30
Reporting years
2012 – 2025
First sample
2012-12-29
Latest sample
2026-01-02
Source regional dataset
Region 8 - Santa Ana
Source retrieved
Aug 21, 2026

Official SMARTS public reports

Parameters reported

Reported results over time

Loading reported results…

Most recent reported results

Latest 25 of 1,335
Sample dateLocationParameterResultUnitsEvent
2026-01-02East drivewayAluminum206ug/LRain Event
2026-01-02East drivewayChemical oxygen demand (COD)ND (non-detect / est.)mg/LRain Event
2026-01-02East drivewayCopper20.2ug/LRain Event
2026-01-02East drivewayElectrical Conductivity250umhos/cmRain Event
2026-01-02East drivewayIron130ug/LRain Event
2026-01-02East drivewayLead2.15ug/LRain Event
2026-01-02East drivewayOil and GreaseND (non-detect / est.)mg/LRain Event
2026-01-02East drivewaypH7SURain Event
2026-01-02East drivewayTurbidity90NTURain Event
2026-01-02East drivewayZinc105ug/LRain Event
2025-11-14East drivewayAluminum537ug/LRain Event
2025-11-14East drivewayChemical oxygen demand (COD)122mg/LRain Event
2025-11-14East drivewayCopper94.6ug/LRain Event
2025-11-14East drivewayElectrical Conductivity250umhos/cmRain Event
2025-11-14East drivewayIron504ug/LRain Event
2025-11-14East drivewayLead8.1ug/LRain Event
2025-11-14East drivewayOil and GreaseND (non-detect / est.)mg/LRain Event
2025-11-14East drivewaypH7SURain Event
2025-11-14East drivewayTurbidity95NTURain Event
2025-11-14East drivewayZinc335ug/LRain Event
2025-11-14West drivewayAluminum675ug/LRain Event
2025-11-14West drivewayChemical oxygen demand (COD)126mg/LRain Event
2025-11-14West drivewayCopper103ug/LRain Event
2025-11-14West drivewayElectrical Conductivity250umhos/cmRain Event
2025-11-14West drivewayIron672ug/LRain Event

Monitoring rows are official self-reported SMARTS submissions, joined to this facility by WDID. California Stormwater Intelligence does not restate, correct, average or evaluate reported values, and no benchmark comparison or violation determination is made.

YDOS-derived

Numeric Action Level comparison

Reported SMARTS analytical results compared against the Numeric Action Levels of the Industrial General Permit version in effect for each reporting year (July 1 – June 30).

Derived
Reporting years evaluated
11
Years with an NAL exceedance
11
Most recent evaluated year
RY 2025
Ruleset
igp_nal_ruleset_v1 / igp_nal_v1
ParameterNAL typeCalculated valueNALResultSamples usedMethod

Aluminum, Total Recoverable

aluminum_total

Annual0.426 mg/L0.75 mg/LAt or below NALAnnual average of 5 eligible result(s) compared with the annual NAL.0.57× threshold5 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Chemical Oxygen Demand (COD)

cod

Annual63.3 mg/L120 mg/LAt or below NALAnnual average of 5 eligible result(s) compared with the annual NAL.0.53× threshold5 eligible1 non-detect as zeroarithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Copper, Total Recoverable

copper_total

Annual0.1 mg/L0.033 mg/LAbove NALAnnual average of 5 eligible result(s) compared with the annual NAL.3.02× threshold5 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Iron, Total Recoverable

iron_total

Annual0.419 mg/L1 mg/LAt or below NALAnnual average of 5 eligible result(s) compared with the annual NAL.0.42× threshold5 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Lead, Total Recoverable

lead_total

Annual0.007 mg/L0.262 mg/LAt or below NALAnnual average of 5 eligible result(s) compared with the annual NAL.0.03× threshold5 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Oil and Grease

oil_grease

Instantaneous maximum0 samples above25 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.5 eligible4 non-detect as zerocount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

pH

ph

Instantaneous maximum0 samples above6 – 9 pH unitsWithin NAL rangeNo eligible result in this reporting year was outside the instantaneous maximum NAL.5 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Zinc, Total Recoverable

zinc_total

Annual0.329 mg/L0.26 mg/LAbove NALAnnual average of 5 eligible result(s) compared with the annual NAL.1.26× threshold5 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

YDOS-derived overlap

Pollutant overlap with impaired receiving waters

Parameters where this facility has an NAL exceedance in at least one reporting year and the geographically associated waterbody carries a 303(d) listing for the same pollutant.

Derived

CopperMonitoringAbove NAL303(d) impairmentNewport Bay, Upper (Ecological Reserve)

10 reporting years above the annual NAL, most recently RY 2025 · 1 303(d) listing · association: derived watershed association (low confidence)

CopperMonitoringAbove NAL303(d) impairmentPeters Canyon Wash (Orange County)

10 reporting years above the annual NAL, most recently RY 2025 · 1 303(d) listing · association: derived watershed association (low confidence)

Overlap is informational co-occurrence between a derived NAL comparison and an official 303(d) listing. It is not evidence that this facility caused or contributed to the impairment.

An NAL exceedance is a permit-defined condition that triggers Exceedance Response Actions under the Industrial General Permit. It is not a violation, an enforcement action, or a Water Board compliance determination. Annual values use the arithmetic average of eligible results with non-detects treated as zero; instantaneous maximum NALs (total suspended solids, oil and grease, pH) are exceeded when two or more eligible results in a reporting year fall outside the level. Rules transcribed from 2014-0057-DWQ as amended by 2015-0122-DWQ (effective 2015-07-01, superseded 2020-06-30); 2014-0057-DWQ as amended by 2018-0028-DWQ (effective 2020-07-01).

Provenance

Source & provenance

Source agency
California State Water Resources Control Board
Source dataset
Industrial General Permit — permitted facilities (statewide GIS layer)
WDID
8 30MR000029
Source feature ID
19671
Application type
Region 8 - Scrap Metal Permit
Regional board derivation
WDID region prefix
Geometry status
valid
Last successful facility import
Aug 21, 2026, 1:57 AM UTC

Official IGP permitted facilities feature layer