← Facilities

Industrial stormwater facility

City of Visalia Corp Yard

WDID 5F54I002343 · Notice of Intent · Visalia, Tulare

SIC 4212 · Local Trucking Without Storage · Regional Board 5 - Central Valley Region

Official record — State Water Resources Control Board, Industrial General Permit

Hydrologic

Geographic context

Official facility coordinate plotted against the associated Final 2026 Integrated Report impaired-water geometry.

Loading map…
  • Facility location (official coordinate)
  • Associated impaired-water geometry (Final 2026 Integrated Report)
  • YDOS-derived geographic context
  • Loading associated geometry…

Geometry shown is limited to waterbodies geographically associated with this facility. Geographic association does not establish a discharge connection, receiving-water connectivity, or causation.

Official facility point
36.33234, -119.27874
HUC12 subwatershed
Mill Creek
HUC12 code
180300071301
Impaired-water associations (derived)
1

Official

Facility record

Facility name
City of Visalia Corp Yard
WDID
5F54I002343
Application type
Notice of Intent
City
Visalia
County
Tulare
ZIP
93292
Primary SIC code
4212
SIC description
Local Trucking Without Storage
Date active
1992-03-31
Regional Water Board
Regional Board 5 - Central Valley Region

303(d) context

Associated impaired waters

Grouped by derived geographic association class.

Derived

Subwatershed + nearby

1 waterbodies
Mill Creek (Tulare County)

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (2) Ammonia (Unionized), Toxicity

Distance 0.19 km

Confidence high

Fact sheet

Associations are calculated from official facility coordinates, USGS HUC12 boundaries, and official 2026 impaired-water geometry. They do not establish a discharge connection or causation.

TMDL requirements

Water Board-stated TMDL waste load allocations applied to this industrial permit in SMARTS.

Official record — SMARTS TMDL dataset, State Water Board

No SMARTS TMDL requirement is recorded for this WDID. In the statewide TMDL export only permits in Regions 4, 8 and 9 currently carry industrial TMDL requirements, so an absence here is not a statement that the facility discharges to an unimpaired water.

Official monitoring

SMARTS monitoring

Self-reported industrial stormwater sampling results as submitted by the discharger to SMARTS.

Official record — SMARTS parameter data, State Water Board
Reported results
418
Sample events
76
Distinct parameters
10
Reporting years
2015 – 2025
First sample
2015-11-02
Latest sample
2025-11-14
Source regional dataset
Region 5F - Fresno
Source retrieved
Aug 21, 2026

Official SMARTS public reports

Parameters reported

Reported results over time

Loading reported results…

Most recent reported results

Latest 25 of 418
Sample dateLocationParameterResultUnitsEvent
2025-11-14Corp Yard Fuel V-GutterChemical oxygen demand (COD)1200mg/LQualifying Storm Event
2025-11-14Corp Yard Fuel V-GutterOil1700mg/LQualifying Storm Event
2025-11-14Corp Yard Fuel V-GutterOil and Grease2.9mg/LQualifying Storm Event
2025-11-14Corp Yard Fuel V-GutterpH6.8SUQualifying Storm Event
2025-11-14Corp Yard Fuel V-GutterTotal Suspended Solids (TSS)43mg/LQualifying Storm Event
2025-11-14Corp Yard Fuel V-GutterZinc.21mg/LQualifying Storm Event
2025-11-14Corp Yard ManholeOil1400mg/LQualifying Storm Event
2025-11-14Corp Yard ManholeOil and Grease4.4mg/LQualifying Storm Event
2025-11-14Corp Yard ManholepH7.1SUQualifying Storm Event
2025-11-14Corp Yard ManholeTotal Suspended Solids (TSS)64mg/LQualifying Storm Event
2025-11-14Corp Yard ManholeZinc.18mg/LQualifying Storm Event
2025-11-14Corp Yard NW V-GutterOil3300mg/LQualifying Storm Event
2025-11-14Corp Yard NW V-GutterOil and Grease6.1mg/LQualifying Storm Event
2025-11-14Corp Yard NW V-GutterpH7.1SUQualifying Storm Event
2025-11-14Corp Yard NW V-GutterTotal Suspended Solids (TSS)100mg/LQualifying Storm Event
2025-11-14Corp Yard NW V-GutterZinc.25mg/LQualifying Storm Event
2025-11-14Corp Yard SE GateBOD, Biochemical oxygen demand33mg/LQualifying Storm Event
2025-11-14Corp Yard SE GateChemical oxygen demand (COD)84mg/LQualifying Storm Event
2025-11-14Corp Yard SE GateOil2200mg/LQualifying Storm Event
2025-11-14Corp Yard SE GateOil and Grease4.3mg/LQualifying Storm Event
2025-11-14Corp Yard SE GatepH7.3SUQualifying Storm Event
2025-11-14Corp Yard SE GateTotal Suspended Solids (TSS)110mg/LQualifying Storm Event
2025-11-14Corp Yard SE GateZinc.82mg/LQualifying Storm Event
2025-11-14Corp Yard SW V-GutterOil1600mg/LQualifying Storm Event
2025-11-14Corp Yard SW V-GutterOil and Grease4.7mg/LQualifying Storm Event

Monitoring rows are official self-reported SMARTS submissions, joined to this facility by WDID. California Stormwater Intelligence does not restate, correct, average or evaluate reported values, and no benchmark comparison or violation determination is made.

YDOS-derived

Numeric Action Level comparison

Reported SMARTS analytical results compared against the Numeric Action Levels of the Industrial General Permit version in effect for each reporting year (July 1 – June 30).

Derived
Reporting years evaluated
8
Years with an NAL exceedance
3
Most recent evaluated year
RY 2025
Ruleset
igp_nal_ruleset_v1 / igp_nal_v1
ParameterNAL typeCalculated valueNALResultSamples usedMethod

Biochemical Oxygen Demand (BOD) (5-day @ 20 Deg. C)

bod

Annual33 mg/L30 mg/LAbove NALAnnual average of 1 eligible result(s) compared with the annual NAL.1.1× threshold1 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Chemical Oxygen Demand (COD)

cod

Annual642 mg/L120 mg/LAbove NALAnnual average of 2 eligible result(s) compared with the annual NAL.5.35× threshold2 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Oil and Grease

oil_grease

Instantaneous maximum0 samples above25 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.5 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

pH

ph

Instantaneous maximum0 samples above6 – 9 pH unitsWithin NAL rangeNo eligible result in this reporting year was outside the instantaneous maximum NAL.5 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Total Suspended Solids (TSS)

tss

Instantaneous maximum0 samples above400 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.5 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Zinc, Total

zinc_total

Annual0.532 mg/L0.26 mg/LAbove NALAnnual average of 5 eligible result(s) compared with the annual NAL.2.05× threshold5 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

An NAL exceedance is a permit-defined condition that triggers Exceedance Response Actions under the Industrial General Permit. It is not a violation, an enforcement action, or a Water Board compliance determination. Annual values use the arithmetic average of eligible results with non-detects treated as zero; instantaneous maximum NALs (total suspended solids, oil and grease, pH) are exceeded when two or more eligible results in a reporting year fall outside the level. Rules transcribed from 2014-0057-DWQ as amended by 2015-0122-DWQ (effective 2015-07-01, superseded 2020-06-30); 2014-0057-DWQ as amended by 2018-0028-DWQ (effective 2020-07-01).

Documents

Documents on file

Attachment inventory recorded in the State Water Board SMARTS public attachment workflow for this permit.

Source inventory — SMARTS public attachments. Documents are operator-submitted.

No document inventory has been indexed for this permit yet. The statewide document index is being built out; coverage is reported on the data-freshness panel.

Attachments for this permit remain viewable in the source system. Open the SMARTS public workflow

Enforcement

Enforcement records

Enforcement actions as recorded by the State Water Board for this permit, in the source system's own terminology.

Source record — SMARTS enforcement data

Structured enforcement records are not yet connected for this site. The absence of a record is not a finding about this facility.

Reporting

Reporting and ERA records

Annual report and Exceedance Response Action information as stated by the source system, distinguished from what is inferred from document metadata.

Source record — SMARTS reporting data

Structured reporting and ERA records are not yet connected for this site.

Recent activity

Recent source changes

New or changed source records this platform detected for this permit, newest first.

Derived

No source change has been detected for this permit yet. Change detection begins from the date each dataset was first indexed.

Provenance

Source & provenance

Source agency
California State Water Resources Control Board
Source dataset
Industrial General Permit — permitted facilities (statewide GIS layer)
WDID
5F54I002343
Source feature ID
13891
Application type
Notice of Intent
Regional board derivation
WDID region prefix
Geometry status
valid
Last successful facility import
Sep 16, 2026, 10:48 PM UTC

Official IGP permitted facilities feature layer