← Facilities

Industrial stormwater facility

Ekco Metals

4 19I002463 · Notice of Intent · Los Angeles, Los Angeles

Official record — State Water Resources Control Board, Industrial General Permit

Official

Facility record

Facility name
Ekco Metals
WDID
4 19I002463
Application type
Notice of Intent
City
Los Angeles
County
Los Angeles
ZIP
90023
Primary SIC code
5093
SIC description
Scrap and Waste Materials
Date active
1992-04-01
Regional Water Board
Regional Board 4 - Los Angeles Region

Hydrologic

Geographic context

Official facility coordinate plotted against the official 2026 impaired-water geometry.

Official facility point
34.01736, -118.22049
HUC12 subwatershed
Chavez Ravine-Los Angeles River
HUC12 code
180701050401
Impaired-water associations (derived)
3
Loading map…

303(d) context

Associated impaired waters

Grouped by derived geographic association class.

Derived

Subwatershed + nearby

1 waterbodies
Los Angeles River Reach 2 (Carson to Figueroa Street)

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (9) Ammonia, Copper, Indicator Bacteria, Lead, Nutrients (Algae), Oil +3 more

Distance 0.27 km

Confidence high

Fact sheet

Same impaired-water subwatershed

2 waterbodies
Lincoln Park Lake

Lake & Reservoir · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (6) Ammonia, Eutrophic, Odor, Organic Enrichment/Low Dissolved Oxygen, PCBs (Polychlorinated biphenyls), Trash

Distance

Confidence low

Fact sheet

Los Angeles River Reach 3 (Figueroa St. to Riverside Dr.)

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (5) Copper, Indicator Bacteria, Nutrients (Algae), Toxicity, Trash

Distance

Confidence low

Fact sheet

Associations are calculated from official facility coordinates, USGS HUC12 boundaries, and official 2026 impaired-water geometry. They do not establish a discharge connection or causation.

TMDL requirements (4)

Numeric effluent limits and action levels stated by the Water Board for this permit, with the receiving water named in the TMDL.

Official record — SMARTS TMDL dataset, State Water Board
Stated requirements
4
TMDLs
1
Regulated parameters
4
Limit due dates
2020-07-01 – 2020-07-01
Includes interim limits
No
Source regional dataset
Region 4 - Los Angeles
Source retrieved
Aug 21, 2026

Official SMARTS public reports

Los Angeles River Metals TMDL

Receiving water named in TMDL Los Angeles River and Los Angeles River Tributaries

4 limits
ParameterLimit typePeriodBasisLimitDue dateReported results for parameter
Cadmium, TotalVocabulary match: Cadmium (narrower)NELFINALINSTANTANEOUS.0031 mg/L2020-07-0193 results · latest 2026-02-17
Copper, TotalVocabulary match: Copper (narrower)NELFINALINSTANTANEOUS.06749 mg/L2020-07-0193 results · latest 2026-02-17
Lead, TotalVocabulary match: Lead (narrower)NELFINALINSTANTANEOUS.094 mg/L2020-07-01171 results · latest 2026-02-17
Zinc, TotalVocabulary match: Zinc (narrower)NELFINALINSTANTANEOUS.159 mg/L2020-07-0193 results · latest 2026-02-17
Derivedapplies only to the 303(d) waterbody link and the parameter vocabulary match.

Limit values, limit periods, parameters, TMDL names and receiving-water names are reproduced exactly as stated by the Water Board in SMARTS. California Stormwater Intelligence does not compare reported monitoring results to these limits and makes no exceedance, violation or compliance determination. Where a stated receiving-water name is linked to a 2026 303(d) waterbody, that link is a derived exact-name match, not a Water Board determination.

Official monitoring

SMARTS monitoring

Self-reported industrial stormwater sampling results as submitted by the discharger to SMARTS.

Official record — SMARTS parameter data, State Water Board
Reported results
1,406
Sample events
93
Distinct parameters
19
Reporting years
2015 – 2025
First sample
2015-09-15
Latest sample
2026-02-17
Source regional dataset
Region 4 - Los Angeles
Source retrieved
Aug 21, 2026

Official SMARTS public reports

Parameters reported

Reported results over time

Loading reported results…

Most recent reported results

Latest 25 of 1,406
Sample dateLocationParameterResultUnitsEvent
2026-02-17Yard 1Aluminum.14mg/LQualifying Storm Event
2026-02-17Yard 1ArsenicND (non-detect / est.)mg/LQualifying Storm Event
2026-02-17Yard 1CadmiumDNQ .000058(non-detect / est.)mg/LQualifying Storm Event
2026-02-17Yard 1Chemical oxygen demand (COD)ND (non-detect / est.)mg/LQualifying Storm Event
2026-02-17Yard 1Copper.036mg/LQualifying Storm Event
2026-02-17Yard 1IronND (non-detect / est.)mg/LQualifying Storm Event
2026-02-17Yard 1Lead.0096mg/LQualifying Storm Event
2026-02-17Yard 1Nickel.0021mg/LQualifying Storm Event
2026-02-17Yard 1Oil and Grease1.6mg/LQualifying Storm Event
2026-02-17Yard 1pH6.9SUQualifying Storm Event
2026-02-17Yard 1Total Suspended Solids (TSS)3.7mg/LQualifying Storm Event
2026-02-17Yard 1ZincDNQ .019(non-detect / est.)mg/LQualifying Storm Event
2026-02-17Yard 2Aluminum.36mg/LQualifying Storm Event
2026-02-17Yard 2ArsenicDNQ .00067(non-detect / est.)mg/LQualifying Storm Event
2026-02-17Yard 2CadmiumDNQ .00031(non-detect / est.)mg/LQualifying Storm Event
2026-02-17Yard 2Chemical oxygen demand (COD)DNQ 36(non-detect / est.)mg/LQualifying Storm Event
2026-02-17Yard 2Copper.14mg/LQualifying Storm Event
2026-02-17Yard 2IronND (non-detect / est.)mg/LQualifying Storm Event
2026-02-17Yard 2Lead.027mg/LQualifying Storm Event
2026-02-17Yard 2Nickel.003mg/LQualifying Storm Event
2026-02-17Yard 2Oil and Grease1.8mg/LQualifying Storm Event
2026-02-17Yard 2pH6.8SUQualifying Storm Event
2026-02-17Yard 2Total Suspended Solids (TSS)6.6mg/LQualifying Storm Event
2026-02-17Yard 2Zinc.029mg/LQualifying Storm Event
2026-02-17Yard 3Aluminum.22mg/LQualifying Storm Event

Monitoring rows are official self-reported SMARTS submissions, joined to this facility by WDID. California Stormwater Intelligence does not restate, correct, average or evaluate reported values, and no benchmark comparison or violation determination is made.

YDOS-derived

Numeric Action Level comparison

Reported SMARTS analytical results compared against the Numeric Action Levels of the Industrial General Permit version in effect for each reporting year (July 1 – June 30).

Derived
Reporting years evaluated
11
Years with an NAL exceedance
9
Most recent evaluated year
RY 2025
Ruleset
igp_nal_ruleset_v1 / igp_nal_v1
ParameterNAL typeCalculated valueNALResultSamples usedMethod

Aluminum, Total

aluminum_total

Annual0.222 mg/L0.75 mg/LAt or below NALAnnual average of 6 eligible result(s) compared with the annual NAL.0.3× threshold6 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Arsenic, Total

arsenic_total

Annual0 mg/L0.15 mg/LAt or below NALAnnual average of 6 eligible result(s) compared with the annual NAL.0× threshold6 eligible6 non-detect as zeroarithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Cadmium, Total

cadmium_total

Annual0 mg/L0.005 mg/LAt or below NALAnnual average of 6 eligible result(s) compared with the annual NAL.0× threshold6 eligible6 non-detect as zeroarithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Chemical Oxygen Demand (COD)

cod

Annual0 mg/L120 mg/LAt or below NALAnnual average of 6 eligible result(s) compared with the annual NAL.0× threshold6 eligible6 non-detect as zeroarithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Copper, Total

copper_total

Annual0.071 mg/L0.033 mg/LAbove NALAnnual average of 6 eligible result(s) compared with the annual NAL.2.13× threshold6 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Iron, Total

iron_total

Annual0.083 mg/L1 mg/LAt or below NALAnnual average of 6 eligible result(s) compared with the annual NAL.0.08× threshold6 eligible5 non-detect as zeroarithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Lead, Total

lead_total

Annual0.014 mg/L0.262 mg/LAt or below NALAnnual average of 6 eligible result(s) compared with the annual NAL.0.06× threshold6 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Nickel, Total

nickel_total

Annual0.002 mg/l1.02 mg/lAt or below NALAnnual average of 6 eligible result(s) compared with the annual NAL.0× threshold6 eligible2 non-detect as zeroarithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Oil and Grease

oil_grease

Instantaneous maximum0 samples above25 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.6 eligible1 non-detect as zerocount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

pH

ph

Instantaneous maximum1 sample above6 – 9 pH unitsWithin NAL rangeOne eligible result in this reporting year was outside the instantaneous maximum NAL. The Order states the condition as two or more results in one reporting year.6 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Total Suspended Solids (TSS)

tss

Instantaneous maximum0 samples above400 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.6 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Zinc, Total

zinc_total

Annual0.03 mg/L0.26 mg/LAt or below NALAnnual average of 6 eligible result(s) compared with the annual NAL.0.12× threshold6 eligible2 non-detect as zeroarithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

YDOS-derived overlap

Pollutant overlap with impaired receiving waters

Parameters where this facility has an NAL exceedance in at least one reporting year and the geographically associated waterbody carries a 303(d) listing for the same pollutant.

Derived

CopperMonitoringAbove NAL303(d) impairmentLos Angeles River Reach 2 (Carson to Figueroa Street)

9 reporting years above the annual NAL, most recently RY 2025 · 1 303(d) listing · 1 stated TMDL requirement · association: derived nearby in watershed (high confidence)

CopperMonitoringAbove NAL303(d) impairmentLos Angeles River Reach 3 (Figueroa St. to Riverside Dr.)

9 reporting years above the annual NAL, most recently RY 2025 · 1 303(d) listing · 1 stated TMDL requirement · association: derived watershed association (low confidence)

Overlap is informational co-occurrence between a derived NAL comparison and an official 303(d) listing. It is not evidence that this facility caused or contributed to the impairment.

An NAL exceedance is a permit-defined condition that triggers Exceedance Response Actions under the Industrial General Permit. It is not a violation, an enforcement action, or a Water Board compliance determination. Annual values use the arithmetic average of eligible results with non-detects treated as zero; instantaneous maximum NALs (total suspended solids, oil and grease, pH) are exceeded when two or more eligible results in a reporting year fall outside the level. Rules transcribed from 2014-0057-DWQ as amended by 2015-0122-DWQ (effective 2015-07-01, superseded 2020-06-30); 2014-0057-DWQ as amended by 2018-0028-DWQ (effective 2020-07-01).

Provenance

Source & provenance

Source agency
California State Water Resources Control Board
Source dataset
Industrial General Permit — permitted facilities (statewide GIS layer)
WDID
4 19I002463
Source feature ID
11299
Application type
Notice of Intent
Regional board derivation
WDID region prefix
Geometry status
valid
Last successful facility import
Aug 21, 2026, 1:57 AM UTC

Official IGP permitted facilities feature layer