← Facilities

Industrial stormwater facility

Flexo Technologies

4 19I013207 · Notice of Intent · South El Monte, Los Angeles

Official record — State Water Resources Control Board, Industrial General Permit

Official

Facility record

Facility name
Flexo Technologies
WDID
4 19I013207
Application type
Notice of Intent
City
South El Monte
County
Los Angeles
ZIP
91719
Primary SIC code
2893
SIC description
Printing Ink
Date active
1997-06-18
Regional Water Board
Regional Board 4 - Los Angeles Region

Hydrologic

Geographic context

Official facility coordinate plotted against the official 2026 impaired-water geometry.

Official facility point
34.05182, -118.05273
HUC12 subwatershed
Alhambra Wash-Rio Hondo
HUC12 code
180701050303
Impaired-water associations (derived)
4
Loading map…

303(d) context

Associated impaired waters

Grouped by derived geographic association class.

Derived

Same impaired-water subwatershed

4 waterbodies
Legg Lake

Lake & Reservoir · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (8) Ammonia, Chlorophyll-a, DDT (Dichlorodiphenyltrichloroethane), Mercury, Odor, PCBs (Polychlorinated biphenyls) +2 more

Distance

Confidence low

Fact sheet

Rio Hondo Reach 1 (Confl. LA River to Snt Ana Fwy)

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (8) Copper, Indicator Bacteria, Lead, Oil and Grease, pH, Toxicity +2 more

Distance

Confidence low

Fact sheet

Rio Hondo Reach 2 (At Spreading Grounds)

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (2) Coliform Bacteria, Cyanide

Distance

Confidence low

Fact sheet

Rio Hondo Reach 3 (above Spreading Grounds)

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (5) Copper, Indicator Bacteria, Iron, Oxygen, Dissolved, Zinc

Distance

Confidence low

Fact sheet

Associations are calculated from official facility coordinates, USGS HUC12 boundaries, and official 2026 impaired-water geometry. They do not establish a discharge connection or causation.

TMDL requirements

Water Board-stated TMDL waste load allocations applied to this industrial permit in SMARTS.

Official record — SMARTS TMDL dataset, State Water Board

No SMARTS TMDL requirement is recorded for this WDID. In the statewide TMDL export only permits in Regions 4, 8 and 9 currently carry industrial TMDL requirements, so an absence here is not a statement that the facility discharges to an unimpaired water.

Official monitoring

SMARTS monitoring

Self-reported industrial stormwater sampling results as submitted by the discharger to SMARTS.

Official record — SMARTS parameter data, State Water Board
Reported results
206
Sample events
67
Distinct parameters
4
Reporting years
2015 – 2025
First sample
2015-12-22
Latest sample
2026-02-16
Source regional dataset
Region 4 - Los Angeles
Source retrieved
Aug 21, 2026

Official SMARTS public reports

Parameters reported

Reported results over time

Loading reported results…

Most recent reported results

Latest 25 of 206
Sample dateLocationParameterResultUnitsEvent
2026-02-16Front LotOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2026-02-16Front LotpH7.5SUQualifying Storm Event
2026-02-16Front LotTotal Suspended Solids (TSS)12mg/LQualifying Storm Event
2026-02-16Rear LotOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2026-02-16Rear LotpH7.4SUQualifying Storm Event
2026-02-16Rear LotTotal Suspended Solids (TSS)8mg/LQualifying Storm Event
2025-11-14Front LotOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2025-11-14Front LotpH7SUQualifying Storm Event
2025-11-14Front LotTotal Suspended Solids (TSS)23mg/LQualifying Storm Event
2025-11-14Rear LotOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2025-11-14Rear LotpH7SUQualifying Storm Event
2025-11-14Rear LotTotal Suspended Solids (TSS)18mg/LQualifying Storm Event
2025-10-14Front LotOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2025-10-14Front LotpH7.7SUQualifying Storm Event
2025-10-14Front LotTotal Suspended Solids (TSS)72mg/LQualifying Storm Event
2025-10-14Rear LotOil and Grease2.4mg/LQualifying Storm Event
2025-10-14Rear LotpH7.9SUQualifying Storm Event
2025-10-14Rear LotTotal Suspended Solids (TSS)64mg/LQualifying Storm Event
2025-03-05Front LotOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2025-03-05Front LotpH7.6SUQualifying Storm Event
2025-03-05Front LotTotal Suspended Solids (TSS)110mg/LQualifying Storm Event
2025-03-05Rear LotOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2025-03-05Rear LotpH7.5SUQualifying Storm Event
2025-03-05Rear LotTotal Suspended Solids (TSS)62mg/LQualifying Storm Event
2025-02-13Front LotOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event

Monitoring rows are official self-reported SMARTS submissions, joined to this facility by WDID. California Stormwater Intelligence does not restate, correct, average or evaluate reported values, and no benchmark comparison or violation determination is made.

YDOS-derived

Numeric Action Level comparison

Reported SMARTS analytical results compared against the Numeric Action Levels of the Industrial General Permit version in effect for each reporting year (July 1 – June 30).

Derived
Reporting years evaluated
11
Years with an NAL exceedance
0
Most recent evaluated year
RY 2025
Ruleset
igp_nal_ruleset_v1 / igp_nal_v1
ParameterNAL typeCalculated valueNALResultSamples usedMethod

Oil and Grease

oil_grease

Instantaneous maximum0 samples above25 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.6 eligible5 non-detect as zerocount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

pH

ph

Instantaneous maximum0 samples above6 – 9 pH unitsWithin NAL rangeNo eligible result in this reporting year was outside the instantaneous maximum NAL.6 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Total Suspended Solids (TSS)

tss

Instantaneous maximum0 samples above400 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.6 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

An NAL exceedance is a permit-defined condition that triggers Exceedance Response Actions under the Industrial General Permit. It is not a violation, an enforcement action, or a Water Board compliance determination. Annual values use the arithmetic average of eligible results with non-detects treated as zero; instantaneous maximum NALs (total suspended solids, oil and grease, pH) are exceeded when two or more eligible results in a reporting year fall outside the level. Rules transcribed from 2014-0057-DWQ as amended by 2015-0122-DWQ (effective 2015-07-01, superseded 2020-06-30); 2014-0057-DWQ as amended by 2018-0028-DWQ (effective 2020-07-01).

Provenance

Source & provenance

Source agency
California State Water Resources Control Board
Source dataset
Industrial General Permit — permitted facilities (statewide GIS layer)
WDID
4 19I013207
Source feature ID
11649
Application type
Notice of Intent
Regional board derivation
WDID region prefix
Geometry status
valid
Last successful facility import
Aug 21, 2026, 1:57 AM UTC

Official IGP permitted facilities feature layer