← Facilities

Industrial stormwater facility

Orchard Machinery Corporation

5S51I019044 · Notice of Intent · Yuba City, Sutter

Official record — State Water Resources Control Board, Industrial General Permit

Official

Facility record

Facility name
Orchard Machinery Corporation
WDID
5S51I019044
Application type
Notice of Intent
City
Yuba City
County
Sutter
ZIP
95993
Primary SIC code
3523
SIC description
Farm Machinery and Equipment
Date active
2004-09-24
Regional Water Board
Regional Board 5 - Central Valley Region

Hydrologic

Geographic context

Official facility coordinate plotted against the official 2026 impaired-water geometry.

Official facility point
39.14138, -121.66182
HUC12 subwatershed
Gilsizer Slough-Snake River
HUC12 code
180201590400
Impaired-water associations (derived)
3
Loading map…

303(d) context

Associated impaired waters

Grouped by derived geographic association class.

Derived

Same impaired-water subwatershed

3 waterbodies
Morrison Slough

River & Stream · Integrated Report category 4b · Addressed by action other than a TMDL

Listed pollutants / stressors (1) Diazinon

Distance

Confidence low

Fact sheet

Sutter Bypass

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (3) Aluminum, Mercury, Oxygen, Dissolved

Distance

Confidence low

Fact sheet

Wadsworth Canal

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (3) Chlorpyrifos, Diazinon, Indicator Bacteria

Distance

Confidence low

Fact sheet

Associations are calculated from official facility coordinates, USGS HUC12 boundaries, and official 2026 impaired-water geometry. They do not establish a discharge connection or causation.

TMDL requirements

Water Board-stated TMDL waste load allocations applied to this industrial permit in SMARTS.

Official record — SMARTS TMDL dataset, State Water Board

No SMARTS TMDL requirement is recorded for this WDID. In the statewide TMDL export only permits in Regions 4, 8 and 9 currently carry industrial TMDL requirements, so an absence here is not a statement that the facility discharges to an unimpaired water.

Official monitoring

SMARTS monitoring

Self-reported industrial stormwater sampling results as submitted by the discharger to SMARTS.

Official record — SMARTS parameter data, State Water Board
Reported results
54
Sample events
14
Distinct parameters
4
Reporting years
2022 – 2025
First sample
2022-12-10
Latest sample
2026-04-21
Source regional dataset
Region 5S - Sacramento
Source retrieved
Aug 21, 2026

Official SMARTS public reports

Parameters reported

Reported results over time

Loading reported results…

Most recent reported results

Latest 25 of 54
Sample dateLocationParameterResultUnitsEvent
2026-04-21Discharge PipeIron3.6mg/LQualifying Storm Event
2026-04-21Discharge PipeOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2026-04-21Discharge PipepH6SUQualifying Storm Event
2026-04-21Discharge PipeTotal Suspended Solids (TSS)84mg/LQualifying Storm Event
2026-02-19Discharge PipeIron28mg/LQualifying Storm Event
2026-02-19Discharge PipeOil and Grease2.6mg/LQualifying Storm Event
2026-02-19Discharge PipepH6SUQualifying Storm Event
2026-02-19Discharge PipeTotal Suspended Solids (TSS)410mg/LQualifying Storm Event
2025-02-04Discharge PipeIron3.2mg/LQualifying Storm Event
2025-02-04Discharge PipeOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2025-02-04Discharge PipepH6SUQualifying Storm Event
2025-02-04Discharge PipeTotal Suspended Solids (TSS)44mg/LQualifying Storm Event
2025-01-31Discharge PipeIron3.9mg/LQualifying Storm Event
2025-01-31Discharge PipepH6SUQualifying Storm Event
2025-01-31Discharge PipeTotal Suspended Solids (TSS)46mg/LQualifying Storm Event
2024-12-12Discharge PipeOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2024-12-12Discharge PipepH6SUQualifying Storm Event
2024-12-12Discharge PipeTotal Suspended Solids (TSS)120mg/LQualifying Storm Event
2024-11-20Discharge PipeIron2.6mg/LQualifying Storm Event
2024-11-20Discharge PipeOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2024-11-20Discharge PipepH6SUQualifying Storm Event
2024-11-20Discharge PipeTotal Suspended Solids (TSS)48mg/LQualifying Storm Event
2024-02-04DW3Iron5.7mg/LQualifying Storm Event
2024-02-04DW3Oil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2024-02-04DW3pH6SUQualifying Storm Event

Monitoring rows are official self-reported SMARTS submissions, joined to this facility by WDID. California Stormwater Intelligence does not restate, correct, average or evaluate reported values, and no benchmark comparison or violation determination is made.

YDOS-derived

Numeric Action Level comparison

Reported SMARTS analytical results compared against the Numeric Action Levels of the Industrial General Permit version in effect for each reporting year (July 1 – June 30).

Derived
Reporting years evaluated
4
Years with an NAL exceedance
4
Most recent evaluated year
RY 2025
Ruleset
igp_nal_ruleset_v1 / igp_nal_v1
ParameterNAL typeCalculated valueNALResultSamples usedMethod

Iron, Total

iron_total

Annual15.8 mg/L1 mg/LAbove NALAnnual average of 2 eligible result(s) compared with the annual NAL.15.8× threshold2 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Oil and Grease

oil_grease

Instantaneous maximum0 samples above25 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.2 eligible1 non-detect as zerocount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

pH

ph

Instantaneous maximum0 samples above6 – 9 pH unitsWithin NAL rangeNo eligible result in this reporting year was outside the instantaneous maximum NAL.2 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Total Suspended Solids (TSS)

tss

Instantaneous maximum1 sample above400 mg/LAt or below NALOne eligible result in this reporting year was outside the instantaneous maximum NAL. The Order states the condition as two or more results in one reporting year.2 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

An NAL exceedance is a permit-defined condition that triggers Exceedance Response Actions under the Industrial General Permit. It is not a violation, an enforcement action, or a Water Board compliance determination. Annual values use the arithmetic average of eligible results with non-detects treated as zero; instantaneous maximum NALs (total suspended solids, oil and grease, pH) are exceeded when two or more eligible results in a reporting year fall outside the level. Rules transcribed from 2014-0057-DWQ as amended by 2015-0122-DWQ (effective 2015-07-01, superseded 2020-06-30); 2014-0057-DWQ as amended by 2018-0028-DWQ (effective 2020-07-01).

Provenance

Source & provenance

Source agency
California State Water Resources Control Board
Source dataset
Industrial General Permit — permitted facilities (statewide GIS layer)
WDID
5S51I019044
Source feature ID
15133
Application type
Notice of Intent
Regional board derivation
WDID region prefix
Geometry status
valid
Last successful facility import
Aug 21, 2026, 1:57 AM UTC

Official IGP permitted facilities feature layer