← Facilities

Industrial stormwater facility

Polycoat Products

WDID 4 19I016191 · Notice of Intent · Santa Fe Springs, Los Angeles

SIC 2851 · Paints, Varnishes, Lacquers, Enamels, and Allied Products · Regional Board 4 - Los Angeles Region

Official record — State Water Resources Control Board, Industrial General Permit

Hydrologic

Geographic context

Official facility coordinate plotted against the associated Final 2026 Integrated Report impaired-water geometry.

Loading map…
  • Facility location (official coordinate)
  • Associated impaired-water geometry (Final 2026 Integrated Report)
  • YDOS-derived geographic context
  • Loading associated geometry…

Geometry shown is limited to waterbodies geographically associated with this facility. Geographic association does not establish a discharge connection, receiving-water connectivity, or causation.

Official facility point
33.89789, -118.04003
HUC12 subwatershed
La Mirada Creek
HUC12 code
180701060602
Impaired-water associations (derived)
2

Official

Facility record

Facility name
Polycoat Products
WDID
4 19I016191
Application type
Notice of Intent
City
Santa Fe Springs
County
Los Angeles
ZIP
90670
Primary SIC code
2851
SIC description
Paints, Varnishes, Lacquers, Enamels, and Allied Products
Date active
2000-11-06
Regional Water Board
Regional Board 4 - Los Angeles Region

303(d) context

Associated impaired waters

Grouped by derived geographic association class.

Derived

Subwatershed + nearby

1 waterbodies
Coyote Creek, North Fork

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (4) Indicator Bacteria, Oil and Grease, Selenium, Zinc

Distance 0.11 km

Confidence high

Fact sheet ↗

Same impaired-water subwatershed

1 waterbodies
La Mirada Park Lake

Lake & Reservoir · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (2) DDT (Dichlorodiphenyltrichloroethane), Mercury

Distance —

Confidence low

Fact sheet ↗

Associations are calculated from official facility coordinates, USGS HUC12 boundaries, and official 2026 impaired-water geometry. They do not establish a discharge connection or causation.

TMDL requirements (1)

Numeric effluent limits and action levels stated by the Water Board for this permit, with the receiving water named in the TMDL.

Official record — SMARTS TMDL dataset, State Water Board
Stated requirements
1
TMDLs
1
Regulated parameters
1
Limit due dates
2020-07-01 – 2020-07-01
Includes interim limits
No
Source regional dataset
Region 4 - Los Angeles
Source retrieved
Sep 24, 2026

Official SMARTS public reports ↗

R4 - San Gabriel River Metals and Selenium TMDL

Receiving water named in TMDL R4 - Coyote Creek and its tributary/ies

1 limits
ParameterLimit typePeriodBasisLimitDue dateReported results for parameter
Zinc, TotalVocabulary match: Zinc (narrower)NELFINALINSTANTANEOUS.158 mg/L2020-07-0118 results · latest 2025-02-13
Derivedapplies only to the 303(d) waterbody link and the parameter vocabulary match.

Limit values, limit periods, parameters, TMDL names and receiving-water names are reproduced exactly as stated by the Water Board in SMARTS. California Stormwater Intelligence does not compare reported monitoring results to these limits and makes no exceedance, violation or compliance determination. Where a stated receiving-water name is linked to a 2026 303(d) waterbody, that link is a derived exact-name match, not a Water Board determination.

Official monitoring

SMARTS monitoring

Self-reported industrial stormwater sampling results as submitted by the discharger to SMARTS.

Official record — SMARTS parameter data, State Water Board
Reported results
160
Sample events
49
Distinct parameters
6
Reporting years
2015 – 2024
First sample
2016-01-05
Latest sample
2025-02-13
Source regional dataset
Region 4 - Los Angeles
Source retrieved
Aug 21, 2026

Official SMARTS public reports ↗

Parameters reported

Reported results over time

Loading reported results…

Most recent reported results

Latest 25 of 160
Sample dateLocationParameterResultUnitsEvent
2025-02-1314722 BuildingZinc.37mg/LQualifying Storm Event
2025-02-1314800 BuildingZinc.14mg/LQualifying Storm Event
2025-02-1314800 BuildingZinc.42mg/LQualifying Storm Event
2023-02-2414722 BuildingOil and Grease2.2mg/LQualifying Storm Event
2023-02-2414722 BuildingpH6.35SUQualifying Storm Event
2023-02-2414722 BuildingTotal Suspended Solids (TSS)60mg/LQualifying Storm Event
2023-02-2414722 BuildingZinc.29mg/LQualifying Storm Event
2023-02-2414800 BuildingOil and GreaseND —(non-detect / est.)mg/LQualifying Storm Event
2023-02-2414800 BuildingpH6.92SUQualifying Storm Event
2023-02-2414800 BuildingTotal Suspended Solids (TSS)85mg/LQualifying Storm Event
2023-02-2414800 BuildingZinc.33mg/LQualifying Storm Event
2023-02-2414850 BuildingOil and Grease1.6mg/LQualifying Storm Event
2023-02-2414850 BuildingpH6.11SUQualifying Storm Event
2023-02-2414850 BuildingTotal Suspended Solids (TSS)58mg/LQualifying Storm Event
2023-02-2414850 BuildingZinc.22mg/LQualifying Storm Event
2023-01-0514722 BuildingOil and GreaseND —(non-detect / est.)mg/LQualifying Storm Event
2023-01-0514722 BuildingpH6.9SUQualifying Storm Event
2023-01-0514722 BuildingTotal Suspended Solids (TSS)1.9mg/LQualifying Storm Event
2023-01-0514722 BuildingZinc.076mg/LQualifying Storm Event
2023-01-0514800 BuildingOil and GreaseND —(non-detect / est.)mg/LQualifying Storm Event
2023-01-0514800 BuildingpH6.17SUQualifying Storm Event
2023-01-0514800 BuildingTotal Suspended Solids (TSS)2.8mg/LQualifying Storm Event
2023-01-0514800 BuildingZinc.075mg/LQualifying Storm Event
2023-01-0514850 BuildingOil and Grease1.6mg/LQualifying Storm Event
2023-01-0514850 BuildingpH6.21SUQualifying Storm Event

Monitoring rows are official self-reported SMARTS submissions, joined to this facility by WDID. California Stormwater Intelligence does not restate, correct, average or evaluate reported values, and no benchmark comparison or violation determination is made.

YDOS-derived

Numeric Action Level comparison

Reported SMARTS analytical results compared against the Numeric Action Levels of the Industrial General Permit version in effect for each reporting year (July 1 – June 30).

Derived
Reporting years evaluated
9
Years with an NAL exceedance
2
Most recent evaluated year
RY 2024
Ruleset
igp_nal_ruleset_v1 / igp_nal_v1
ParameterNAL typeCalculated valueNALResultSamples usedMethod

Zinc, Total

zinc_total

Annual0.31 mg/L0.26 mg/LAbove NALAnnual average of 3 eligible result(s) compared with the annual NAL.1.19× threshold3 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

YDOS-derived overlap

Pollutant overlap with impaired receiving waters

Parameters where this facility has an NAL exceedance in at least one reporting year and the geographically associated waterbody carries a 303(d) listing for the same pollutant.

Derived

ZincMonitoringAbove NAL303(d) impairmentCoyote Creek, North Fork

2 reporting years above the annual NAL, most recently RY 2024 · 1 303(d) listing · 1 stated TMDL requirement · association: derived nearby in watershed (high confidence)

Overlap is informational co-occurrence between a derived NAL comparison and an official 303(d) listing. It is not evidence that this facility caused or contributed to the impairment.

An NAL exceedance is a permit-defined condition that triggers Exceedance Response Actions under the Industrial General Permit. It is not a violation, an enforcement action, or a Water Board compliance determination. Annual values use the arithmetic average of eligible results with non-detects treated as zero; instantaneous maximum NALs (total suspended solids, oil and grease, pH) are exceeded when two or more eligible results in a reporting year fall outside the level. Rules transcribed from 2014-0057-DWQ as amended by 2015-0122-DWQ ↗ (effective 2015-07-01, superseded 2020-06-30); 2014-0057-DWQ as amended by 2018-0028-DWQ ↗ (effective 2020-07-01).

Documents

Documents on file

Attachment inventory recorded in the State Water Board SMARTS public attachment workflow for this permit.

Source inventory — SMARTS public attachments. Documents are operator-submitted.

No document inventory has been indexed for this permit yet. The statewide document index is being built out; coverage is reported on the data-freshness panel.

Attachments for this permit remain viewable in the source system. Open the SMARTS public workflow ↗

Enforcement

Enforcement records

Enforcement actions as recorded by the State Water Board for this permit, in the source system's own terminology.

Source record — SMARTS enforcement data

Structured enforcement records are not yet connected for this site. The absence of a record is not a finding about this facility.

Reporting

Reporting and ERA records

Annual report and Exceedance Response Action information as stated by the source system, distinguished from what is inferred from document metadata.

Source record — SMARTS reporting data

Structured reporting and ERA records are not yet connected for this site.

Recent activity

Recent source changes

New or changed source records this platform detected for this permit, newest first.

Derived

No source change has been detected for this permit yet. Change detection begins from the date each dataset was first indexed.

Provenance

Source & provenance

Source agency
California State Water Resources Control Board
Source dataset
Industrial General Permit — permitted facilities (statewide GIS layer)
WDID
4 19I016191
Source feature ID
11772
Application type
Notice of Intent
Regional board derivation
WDID region prefix
Geometry status
valid
Last successful facility import
Sep 16, 2026, 10:48 PM UTC