← Facilities

Industrial stormwater facility

Solar Turbines Harbor Drive Fa

9 37I001827 · Notice of Intent · San Diego, San Diego

Official record — State Water Resources Control Board, Industrial General Permit

Official

Facility record

Facility name
Solar Turbines Harbor Drive Fa
WDID
9 37I001827
Application type
Notice of Intent
City
San Diego
County
San Diego
ZIP
92101
Primary SIC code
3511
SIC description
Steam, Gas, and Hydraulic Turbines, and Turbine Generator Set Units
Date active
1992-03-30
Regional Water Board
Regional Board 9 - San Diego Region

Hydrologic

Geographic context

Official facility coordinate plotted against the official 2026 impaired-water geometry.

Official facility point
32.72650, -117.17246
HUC12 subwatershed
San Diego Bay
HUC12 code
180703041202
Impaired-water associations (derived)
6
Loading map…

303(d) context

Associated impaired waters

Grouped by derived geographic association class.

Derived

Subwatershed + nearby

3 waterbodies
San Diego Bay

Bay & Harbor · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (3) Mercury, PAHs (Polycyclic Aromatic Hydrocarbons), PCBs (Polychlorinated biphenyls)

Distance 0.17 km

Confidence high

Fact sheet

San Diego Bay Shoreline, Downtown Anchorage

Bay & Harbor · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (3) Benthic Community Effects, Sediment Toxicity, Toxicity

Distance 0.23 km

Confidence high

Fact sheet

San Diego Bay Shoreline, at Harbor Island (East Basin)

Bay & Harbor · Integrated Report category 5 · Listed

Listed pollutants / stressors (1) Copper

Distance 0.79 km

Confidence high

Fact sheet

Same impaired-water subwatershed

3 waterbodies
San Diego Bay Shoreline, 32nd St San Diego Naval Station

Bay & Harbor · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (2) Benthic Community Effects, Sediment Toxicity

Distance

Confidence low

Fact sheet

San Diego Bay Shoreline, near Chollas Creek

Bay & Harbor · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (3) Benthic Community Effects, Sediment Toxicity, Toxicity

Distance

Confidence low

Fact sheet

Sweetwater River, Lower (below Sweetwater Reservoir)

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (10) Benthic Community Effects, Bifenthrin, Chlorpyrifos, Indicator Bacteria, Nitrogen, Oxygen, Dissolved +4 more

Distance

Confidence low

Fact sheet

Associations are calculated from official facility coordinates, USGS HUC12 boundaries, and official 2026 impaired-water geometry. They do not establish a discharge connection or causation.

TMDL requirements

Water Board-stated TMDL waste load allocations applied to this industrial permit in SMARTS.

Official record — SMARTS TMDL dataset, State Water Board

No SMARTS TMDL requirement is recorded for this WDID. In the statewide TMDL export only permits in Regions 4, 8 and 9 currently carry industrial TMDL requirements, so an absence here is not a statement that the facility discharges to an unimpaired water.

Official monitoring

SMARTS monitoring

Self-reported industrial stormwater sampling results as submitted by the discharger to SMARTS.

Official record — SMARTS parameter data, State Water Board
Reported results
976
Sample events
110
Distinct parameters
8
Reporting years
2015 – 2024
First sample
2015-09-15
Latest sample
2025-03-11
Source regional dataset
Region 9 - San Diego
Source retrieved
Aug 21, 2026

Official SMARTS public reports

Parameters reported

Reported results over time

Loading reported results…

Most recent reported results

Latest 25 of 976
Sample dateLocationParameterResultUnitsEvent
2025-03-11SP1 - ChapelIron1.2mg/LQualifying Storm Event
2025-03-11SP1 - ChapelIron1.2mg/LQualifying Storm Event
2025-03-11SP1 - ChapelNickel.02mg/LQualifying Storm Event
2025-03-11SP1 - ChapelNickel.02mg/LQualifying Storm Event
2025-03-11SP1 - ChapelOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2025-03-11SP1 - ChapelOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2025-03-11SP1 - ChapelpH8SUQualifying Storm Event
2025-03-11SP1 - ChapelpH8SUQualifying Storm Event
2025-03-11SP1 - ChapelTotal Suspended Solids (TSS)62mg/LQualifying Storm Event
2025-03-11SP1 - ChapelTotal Suspended Solids (TSS)62mg/LQualifying Storm Event
2025-03-11SP2 - Building 18Iron1.4mg/LQualifying Storm Event
2025-03-11SP2 - Building 18Iron1.4mg/LQualifying Storm Event
2025-03-11SP2 - Building 18Nickel.053mg/LQualifying Storm Event
2025-03-11SP2 - Building 18Nickel.053mg/LQualifying Storm Event
2025-03-11SP2 - Building 18Oil and GreaseND 5.7(non-detect / est.)mg/LQualifying Storm Event
2025-03-11SP2 - Building 18Oil and GreaseND 5.7(non-detect / est.)mg/LQualifying Storm Event
2025-03-11SP2 - Building 18pH7.93SUQualifying Storm Event
2025-03-11SP2 - Building 18pH7.93SUQualifying Storm Event
2025-03-11SP2 - Building 18Total Suspended Solids (TSS)53mg/LQualifying Storm Event
2025-03-11SP2 - Building 18Total Suspended Solids (TSS)53mg/LQualifying Storm Event
2025-03-11SP3 - Bldg 21 and Bldg 27Iron.86mg/LQualifying Storm Event
2025-03-11SP3 - Bldg 21 and Bldg 27Iron.86mg/LQualifying Storm Event
2025-03-11SP3 - Bldg 21 and Bldg 27Nickel.0094mg/LQualifying Storm Event
2025-03-11SP3 - Bldg 21 and Bldg 27Nickel.0094mg/LQualifying Storm Event
2025-03-11SP3 - Bldg 21 and Bldg 27Oil and GreaseND (non-detect / est.)mg/LQualifying Storm Event

Monitoring rows are official self-reported SMARTS submissions, joined to this facility by WDID. California Stormwater Intelligence does not restate, correct, average or evaluate reported values, and no benchmark comparison or violation determination is made.

YDOS-derived

Numeric Action Level comparison

Reported SMARTS analytical results compared against the Numeric Action Levels of the Industrial General Permit version in effect for each reporting year (July 1 – June 30).

Derived
Reporting years evaluated
10
Years with an NAL exceedance
8
Most recent evaluated year
RY 2024
Ruleset
igp_nal_ruleset_v1 / igp_nal_v1
ParameterNAL typeCalculated valueNALResultSamples usedMethod

Iron, Total

iron_total

Annual0.816 mg/L1 mg/LAt or below NALAnnual average of 10 eligible result(s) compared with the annual NAL.0.82× threshold10 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Nickel, Total

nickel_total

Annual0.02 mg/l1.02 mg/lAt or below NALAnnual average of 10 eligible result(s) compared with the annual NAL.0.02× threshold10 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Oil and Grease

oil_grease

Instantaneous maximum0 samples above25 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.10 eligible10 non-detect as zerocount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

pH

ph

Instantaneous maximum0 samples above6 – 9 pH unitsWithin NAL rangeNo eligible result in this reporting year was outside the instantaneous maximum NAL.10 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Total Suspended Solids (TSS)

tss

Instantaneous maximum0 samples above400 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.10 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

YDOS-derived overlap

Pollutant overlap with impaired receiving waters

Parameters where this facility has an NAL exceedance in at least one reporting year and the geographically associated waterbody carries a 303(d) listing for the same pollutant.

Derived

CopperMonitoringAbove NAL303(d) impairmentSan Diego Bay Shoreline, at Harbor Island (East Basin)

7 reporting years above the annual NAL, most recently RY 2023 · 1 303(d) listing · association: derived nearby in watershed (high confidence)

Overlap is informational co-occurrence between a derived NAL comparison and an official 303(d) listing. It is not evidence that this facility caused or contributed to the impairment.

An NAL exceedance is a permit-defined condition that triggers Exceedance Response Actions under the Industrial General Permit. It is not a violation, an enforcement action, or a Water Board compliance determination. Annual values use the arithmetic average of eligible results with non-detects treated as zero; instantaneous maximum NALs (total suspended solids, oil and grease, pH) are exceeded when two or more eligible results in a reporting year fall outside the level. Rules transcribed from 2014-0057-DWQ as amended by 2015-0122-DWQ (effective 2015-07-01, superseded 2020-06-30); 2014-0057-DWQ as amended by 2018-0028-DWQ (effective 2020-07-01).

Provenance

Source & provenance

Source agency
California State Water Resources Control Board
Source dataset
Industrial General Permit — permitted facilities (statewide GIS layer)
WDID
9 37I001827
Source feature ID
17286
Application type
Notice of Intent
Regional board derivation
WDID region prefix
Geometry status
valid
Last successful facility import
Aug 21, 2026, 1:57 AM UTC

Official IGP permitted facilities feature layer