← Facilities

Industrial stormwater facility

Strategic Operations

9 37I022955 · Notice of Intent · San Diego, San Diego

Official record — State Water Resources Control Board, Industrial General Permit

Official

Facility record

Facility name
Strategic Operations
WDID
9 37I022955
Application type
Notice of Intent
City
San Diego
County
San Diego
ZIP
92123
Primary SIC code
9999
SIC description
Nonclassifiable Establishments
Date active
2010-12-23
Regional Water Board
Regional Board 9 - San Diego Region

Hydrologic

Geographic context

Official facility coordinate plotted against the official 2026 impaired-water geometry.

Official facility point
32.82560, -117.12738
HUC12 subwatershed
Mission Valley-San Diego River
HUC12 code
180703040705
Impaired-water associations (derived)
3
Loading map…

303(d) context

Associated impaired waters

Grouped by derived geographic association class.

Derived

Nearby impaired water

1 waterbodies
Murphy Canyon

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (3) Benthic Community Effects, Nitrogen, Phosphorus

Distance 0.84 km

Confidence medium

Fact sheet

Same impaired-water subwatershed

2 waterbodies
San Diego River (Lower)

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (16) Benthic Community Effects, Bifenthrin, Chlordane, Chloride, Color, Cyfluthrin +10 more

Distance

Confidence low

Fact sheet

Shepherd Canyon East

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (2) Nitrogen, Phosphorus

Distance

Confidence low

Fact sheet

Associations are calculated from official facility coordinates, USGS HUC12 boundaries, and official 2026 impaired-water geometry. They do not establish a discharge connection or causation.

TMDL requirements

Water Board-stated TMDL waste load allocations applied to this industrial permit in SMARTS.

Official record — SMARTS TMDL dataset, State Water Board

No SMARTS TMDL requirement is recorded for this WDID. In the statewide TMDL export only permits in Regions 4, 8 and 9 currently carry industrial TMDL requirements, so an absence here is not a statement that the facility discharges to an unimpaired water.

Official monitoring

SMARTS monitoring

Self-reported industrial stormwater sampling results as submitted by the discharger to SMARTS.

Official record — SMARTS parameter data, State Water Board
Reported results
30
Sample events
10
Distinct parameters
3
Reporting years
2015 – 2017
First sample
2015-09-15
Latest sample
2018-02-21
Source regional dataset
Region 9 - San Diego
Source retrieved
Aug 21, 2026

Official SMARTS public reports

Parameters reported

Reported results over time

Loading reported results…

Most recent reported results

Latest 25 of 30
Sample dateLocationParameterResultUnitsEvent
2018-02-21South Building #1Oil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2018-02-21South Building #1pH8.3SUQualifying Storm Event
2018-02-21South Building #1Total Suspended Solids (TSS)22mg/LQualifying Storm Event
2018-01-09South Building #1Oil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2018-01-09South Building #1pH7.8SUQualifying Storm Event
2018-01-09South Building #1Total Suspended Solids (TSS)2mg/LQualifying Storm Event
2017-02-06South Building #1Oil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2017-02-06South Building #1pH7.5SUQualifying Storm Event
2017-02-06South Building #1Total Suspended Solids (TSS)16mg/LQualifying Storm Event
2016-12-16South Building #1Oil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2016-12-16South Building #1Oil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2016-12-16South Building #1pH8.1SUQualifying Storm Event
2016-12-16South Building #1pH7.7SUQualifying Storm Event
2016-12-16South Building #1Total Suspended Solids (TSS)8mg/LQualifying Storm Event
2016-12-16South Building #1Total Suspended Solids (TSS)8mg/LQualifying Storm Event
2016-09-21South Building #1Oil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2016-09-21South Building #1pH6.5SUQualifying Storm Event
2016-09-21South Building #1Total Suspended Solids (TSS)2mg/LQualifying Storm Event
2016-09-02Training AreaOil and Grease0mg/LNon-Storm Water Discharge Event
2016-09-02Training AreapH0SUNon-Storm Water Discharge Event
2016-09-02Training AreaTotal Suspended Solids (TSS)0mg/LNon-Storm Water Discharge Event
2016-03-07South Building #1Oil and Grease8.1mg/LQualifying Storm Event
2016-03-07South Building #1pH7.33SUQualifying Storm Event
2016-03-07South Building #1Total Suspended Solids (TSS)552mg/LQualifying Storm Event
2015-12-11South Building #1Oil and Grease10mg/LQualifying Storm Event

Monitoring rows are official self-reported SMARTS submissions, joined to this facility by WDID. California Stormwater Intelligence does not restate, correct, average or evaluate reported values, and no benchmark comparison or violation determination is made.

YDOS-derived

Numeric Action Level comparison

Reported SMARTS analytical results compared against the Numeric Action Levels of the Industrial General Permit version in effect for each reporting year (July 1 – June 30).

Derived
Reporting years evaluated
3
Years with an NAL exceedance
1
Most recent evaluated year
RY 2017
Ruleset
igp_nal_ruleset_v1 / igp_nal_v1
ParameterNAL typeCalculated valueNALResultSamples usedMethod

Oil and Grease

oil_grease

Instantaneous maximum0 samples above25 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.2 eligible2 non-detect as zerocount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

pH

ph

Instantaneous maximum0 samples above6 – 9 pH unitsWithin NAL rangeNo eligible result in this reporting year was outside the instantaneous maximum NAL.2 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Total Suspended Solids (TSS)

tss

Instantaneous maximum0 samples above400 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.2 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

An NAL exceedance is a permit-defined condition that triggers Exceedance Response Actions under the Industrial General Permit. It is not a violation, an enforcement action, or a Water Board compliance determination. Annual values use the arithmetic average of eligible results with non-detects treated as zero; instantaneous maximum NALs (total suspended solids, oil and grease, pH) are exceeded when two or more eligible results in a reporting year fall outside the level. Rules transcribed from 2014-0057-DWQ as amended by 2015-0122-DWQ (effective 2015-07-01, superseded 2020-06-30); 2014-0057-DWQ as amended by 2018-0028-DWQ (effective 2020-07-01).

Provenance

Source & provenance

Source agency
California State Water Resources Control Board
Source dataset
Industrial General Permit — permitted facilities (statewide GIS layer)
WDID
9 37I022955
Source feature ID
17551
Application type
Notice of Intent
Regional board derivation
WDID region prefix
Geometry status
valid
Last successful facility import
Aug 21, 2026, 1:57 AM UTC

Official IGP permitted facilities feature layer