← Facilities

Industrial stormwater facility

Titan Industrial Metal Corporation

8 36MR000078 · Region 8 - Scrap Metal Permit · Rancho Cucamonga, San Bernardino

Official record — State Water Resources Control Board, Industrial General Permit

Official

Facility record

Facility name
Titan Industrial Metal Corporation
WDID
8 36MR000078
Application type
Region 8 - Scrap Metal Permit
City
Rancho Cucamonga
County
San Bernardino
ZIP
91739
Primary SIC code
5093
SIC description
Scrap and Waste Materials
Date active
2019-08-30
Regional Water Board
Regional Board 8 - Santa Ana Region

Hydrologic

Geographic context

Official facility coordinate plotted against the official 2026 impaired-water geometry.

Official facility point
34.09383, -117.51588
HUC12 subwatershed
East Etiwanda Creek-Santa Ana River
HUC12 code
180702030804
Impaired-water associations (derived)
4
Loading map…

303(d) context

Associated impaired waters

Grouped by derived geographic association class.

Derived

Same impaired-water subwatershed

4 waterbodies
Prado Basin Management Zone

Wetland, Freshwater · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (1) pH

Distance

Confidence low

Fact sheet

Santa Ana River, Reach 3

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (7) Benthic Community Effects, Bifenthrin, Copper, Indicator Bacteria, Lead, Pyrethroids +1 more

Distance

Confidence low

Fact sheet

Santa Ana River, Reach 4

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (3) DDT (Dichlorodiphenyltrichloroethane), Indicator Bacteria, Oil and Grease

Distance

Confidence low

Fact sheet

Warm Creek

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (1) Indicator Bacteria

Distance

Confidence low

Fact sheet

Associations are calculated from official facility coordinates, USGS HUC12 boundaries, and official 2026 impaired-water geometry. They do not establish a discharge connection or causation.

TMDL requirements

Water Board-stated TMDL waste load allocations applied to this industrial permit in SMARTS.

Official record — SMARTS TMDL dataset, State Water Board

No SMARTS TMDL requirement is recorded for this WDID. In the statewide TMDL export only permits in Regions 4, 8 and 9 currently carry industrial TMDL requirements, so an absence here is not a statement that the facility discharges to an unimpaired water.

Official monitoring

SMARTS monitoring

Self-reported industrial stormwater sampling results as submitted by the discharger to SMARTS.

Official record — SMARTS parameter data, State Water Board
Reported results
13
Sample events
1
Distinct parameters
13
Reporting years
2020 – 2020
First sample
2020-12-28
Latest sample
2020-12-28
Source regional dataset
Region 8 - Santa Ana
Source retrieved
Aug 21, 2026

Official SMARTS public reports

Parameters reported

Reported results over time

Loading reported results…

Most recent reported results

Latest 25 of 13
Sample dateLocationParameterResultUnitsEvent
2020-12-28DP1Aluminum150ug/LRain Event
2020-12-28DP1Cadmium.064ug/LRain Event
2020-12-28DP1Chemical oxygen demand (COD)33.5mg/LRain Event
2020-12-28DP1Copper12ug/LRain Event
2020-12-28DP1Electrical Conductivity66.7umhos/cmRain Event
2020-12-28DP1Iron230ug/LRain Event
2020-12-28DP1Lead.5ug/LRain Event
2020-12-28DP1Nickel1.3ug/LRain Event
2020-12-28DP1Oil and Grease< .5(non-detect / est.)mg/LRain Event
2020-12-28DP1Petroleum Hydrocarbons, Total< .2(non-detect / est.)mg/LRain Event
2020-12-28DP1pH4.43SURain Event
2020-12-28DP1Turbidity3.92NTURain Event
2020-12-28DP1Zinc53ug/LRain Event

Monitoring rows are official self-reported SMARTS submissions, joined to this facility by WDID. California Stormwater Intelligence does not restate, correct, average or evaluate reported values, and no benchmark comparison or violation determination is made.

YDOS-derived

Numeric Action Level comparison

Reported SMARTS analytical results compared against the Numeric Action Levels of the Industrial General Permit version in effect for each reporting year (July 1 – June 30).

Derived
Reporting years evaluated
1
Years with an NAL exceedance
0
Most recent evaluated year
RY 2020
Ruleset
igp_nal_ruleset_v1 / igp_nal_v1
ParameterNAL typeCalculated valueNALResultSamples usedMethod

Aluminum, Total Recoverable

aluminum_total

Annual0.15 mg/L0.75 mg/LAt or below NALAnnual average of 1 eligible result(s) compared with the annual NAL.0.2× threshold1 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Cadmium, Total Recoverable

cadmium_total

Annual6.40e-5 mg/L0.005 mg/LAt or below NALAnnual average of 1 eligible result(s) compared with the annual NAL.0.01× threshold1 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Chemical Oxygen Demand (COD)

cod

Annual33.5 mg/L120 mg/LAt or below NALAnnual average of 1 eligible result(s) compared with the annual NAL.0.28× threshold1 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Copper, Total Recoverable

copper_total

Annual0.012 mg/L0.033 mg/LAt or below NALAnnual average of 1 eligible result(s) compared with the annual NAL.0.36× threshold1 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Iron, Total Recoverable

iron_total

Annual0.23 mg/L1 mg/LAt or below NALAnnual average of 1 eligible result(s) compared with the annual NAL.0.23× threshold1 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Lead, Total Recoverable

lead_total

Annual5.00e-4 mg/L0.262 mg/LAt or below NALAnnual average of 1 eligible result(s) compared with the annual NAL.0× threshold1 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Nickel, Total Recoverable

nickel_total

Annual0.001 mg/l1.02 mg/lAt or below NALAnnual average of 1 eligible result(s) compared with the annual NAL.0× threshold1 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Oil and Grease

oil_grease

Instantaneous maximum0 samples above25 mg/LNot evaluatedNo eligible analytical results for this reporting year; every reported result was excluded with a stated reason.0 eligible1 excludedcount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

pH

ph

Instantaneous maximum1 sample above6 – 9 pH unitsWithin NAL rangeOne eligible result in this reporting year was outside the instantaneous maximum NAL. The Order states the condition as two or more results in one reporting year.1 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Zinc, Total Recoverable

zinc_total

Annual0.053 mg/L0.26 mg/LAt or below NALAnnual average of 1 eligible result(s) compared with the annual NAL.0.2× threshold1 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

An NAL exceedance is a permit-defined condition that triggers Exceedance Response Actions under the Industrial General Permit. It is not a violation, an enforcement action, or a Water Board compliance determination. Annual values use the arithmetic average of eligible results with non-detects treated as zero; instantaneous maximum NALs (total suspended solids, oil and grease, pH) are exceeded when two or more eligible results in a reporting year fall outside the level. Rules transcribed from 2014-0057-DWQ as amended by 2015-0122-DWQ (effective 2015-07-01, superseded 2020-06-30); 2014-0057-DWQ as amended by 2018-0028-DWQ (effective 2020-07-01).

Provenance

Source & provenance

Source agency
California State Water Resources Control Board
Source dataset
Industrial General Permit — permitted facilities (statewide GIS layer)
WDID
8 36MR000078
Source feature ID
19677
Application type
Region 8 - Scrap Metal Permit
Regional board derivation
WDID region prefix
Geometry status
valid
Last successful facility import
Aug 21, 2026, 1:57 AM UTC

Official IGP permitted facilities feature layer