← Facilities

Industrial stormwater facility

Tubular Steel Inc

WDID 8 36I022652 · Notice of Intent · Rialto, San Bernardino

SIC 3317 · Steel Pipe and Tubes · Regional Board 8 - Santa Ana Region

Official record — State Water Resources Control Board, Industrial General Permit

Hydrologic

Geographic context

Official facility coordinate plotted against the associated Final 2026 Integrated Report impaired-water geometry.

Loading map…
  • Facility location (official coordinate)
  • Associated impaired-water geometry (Final 2026 Integrated Report)
  • YDOS-derived geographic context
  • Loading associated geometry…

Geometry shown is limited to waterbodies geographically associated with this facility. Geographic association does not establish a discharge connection, receiving-water connectivity, or causation.

Official facility point
34.14992, -117.41080
HUC12 subwatershed
East Etiwanda Creek-Santa Ana River
HUC12 code
180702030804
Impaired-water associations (derived)
4

Official

Facility record

Facility name
Tubular Steel Inc
WDID
8 36I022652
Application type
Notice of Intent
City
Rialto
County
San Bernardino
ZIP
92376
Primary SIC code
3317
SIC description
Steel Pipe and Tubes
Date active
2010-05-27
Regional Water Board
Regional Board 8 - Santa Ana Region

303(d) context

Associated impaired waters

Grouped by derived geographic association class.

Derived

Same impaired-water subwatershed

4 waterbodies
Prado Basin Management Zone

Wetland, Freshwater · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (1) pH

Distance

Confidence low

Fact sheet

Santa Ana River, Reach 3

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (7) Benthic Community Effects, Bifenthrin, Copper, Indicator Bacteria, Lead, Pyrethroids +1 more

Distance

Confidence low

Fact sheet

Santa Ana River, Reach 4

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (3) DDT (Dichlorodiphenyltrichloroethane), Indicator Bacteria, Oil and Grease

Distance

Confidence low

Fact sheet

Warm Creek

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (1) Indicator Bacteria

Distance

Confidence low

Fact sheet

Associations are calculated from official facility coordinates, USGS HUC12 boundaries, and official 2026 impaired-water geometry. They do not establish a discharge connection or causation.

TMDL requirements

Water Board-stated TMDL waste load allocations applied to this industrial permit in SMARTS.

Official record — SMARTS TMDL dataset, State Water Board

No SMARTS TMDL requirement is recorded for this WDID. In the statewide TMDL export only permits in Regions 4, 8 and 9 currently carry industrial TMDL requirements, so an absence here is not a statement that the facility discharges to an unimpaired water.

Official monitoring

SMARTS monitoring

Self-reported industrial stormwater sampling results as submitted by the discharger to SMARTS.

Official record — SMARTS parameter data, State Water Board
Reported results
229
Sample events
35
Distinct parameters
9
Reporting years
2015 – 2025
First sample
2015-09-15
Latest sample
2025-10-14
Source regional dataset
Region 8 - Santa Ana
Source retrieved
Aug 21, 2026

Official SMARTS public reports

Parameters reported

Reported results over time

Loading reported results…

Most recent reported results

Latest 25 of 229
Sample dateLocationParameterResultUnitsEvent
2025-10-14Emergency ExitCopper.0029ug/LQualifying Storm Event
2025-10-14Emergency ExitLeadDNQ .00082(non-detect / est.)ug/LQualifying Storm Event
2025-10-14Emergency ExitOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2025-10-14Emergency ExitpH7.62SUQualifying Storm Event
2025-10-14Emergency ExitTotal Suspended Solids (TSS)1.5mg/LQualifying Storm Event
2025-10-14Emergency ExitTPH as Motor OilND (non-detect / est.)mg/LQualifying Storm Event
2025-10-14Emergency ExitZinc.06ug/LQualifying Storm Event
2025-10-14Main EntranceCopper.0078ug/LQualifying Storm Event
2025-10-14Main EntranceLead.0034ug/LQualifying Storm Event
2025-10-14Main EntranceOil and Grease.67mg/LQualifying Storm Event
2025-10-14Main EntrancepH8.47SUQualifying Storm Event
2025-10-14Main EntranceTotal Suspended Solids (TSS)6.7mg/LQualifying Storm Event
2025-10-14Main EntranceTPH as Motor OilND (non-detect / est.)mg/LQualifying Storm Event
2025-10-14Main EntranceZinc.043ug/LQualifying Storm Event
2025-04-02Main EntranceCopper, Dissolved.0035mg/LQualifying Storm Event
2025-04-02Main EntranceLead.0011mg/LQualifying Storm Event
2025-04-02Main EntranceOil and Grease1.7mg/LQualifying Storm Event
2025-04-02Main EntrancepH8.39SUQualifying Storm Event
2025-04-02Main EntranceTotal Suspended Solids (TSS)1.8mg/LQualifying Storm Event
2025-04-02Main EntranceZinc, Dissolved.042mg/LQualifying Storm Event
2025-03-31Emergency ExitCopper, Dissolved.0053mg/LQualifying Storm Event
2025-03-31Emergency ExitLead.0054mg/LQualifying Storm Event
2025-03-31Emergency ExitOil and Grease.67mg/LQualifying Storm Event
2025-03-31Emergency ExitpH8.47SUQualifying Storm Event
2025-03-31Emergency ExitTotal Suspended Solids (TSS)1.5mg/LQualifying Storm Event

Monitoring rows are official self-reported SMARTS submissions, joined to this facility by WDID. California Stormwater Intelligence does not restate, correct, average or evaluate reported values, and no benchmark comparison or violation determination is made.

YDOS-derived

Numeric Action Level comparison

Reported SMARTS analytical results compared against the Numeric Action Levels of the Industrial General Permit version in effect for each reporting year (July 1 – June 30).

Derived
Reporting years evaluated
10
Years with an NAL exceedance
0
Most recent evaluated year
RY 2025
Ruleset
igp_nal_ruleset_v1 / igp_nal_v1
ParameterNAL typeCalculated valueNALResultSamples usedMethod

Copper, Total Recoverable

copper_total

Annual5.35e-6 mg/L0.033 mg/LAt or below NALAnnual average of 2 eligible result(s) compared with the annual NAL.1.61e-4× threshold2 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Lead, Total Recoverable

lead_total

Annual1.70e-6 mg/L0.262 mg/LAt or below NALAnnual average of 2 eligible result(s) compared with the annual NAL.6.00e-6× threshold2 eligible1 non-detect as zeroarithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Oil and Grease

oil_grease

Instantaneous maximum0 samples above25 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.2 eligible1 non-detect as zerocount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

pH

ph

Instantaneous maximum0 samples above6 – 9 pH unitsWithin NAL rangeNo eligible result in this reporting year was outside the instantaneous maximum NAL.2 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Total Suspended Solids (TSS)

tss

Instantaneous maximum0 samples above400 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.2 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Zinc, Total Recoverable

zinc_total

Annual5.15e-5 mg/L0.26 mg/LAt or below NALAnnual average of 2 eligible result(s) compared with the annual NAL.1.98e-4× threshold2 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

An NAL exceedance is a permit-defined condition that triggers Exceedance Response Actions under the Industrial General Permit. It is not a violation, an enforcement action, or a Water Board compliance determination. Annual values use the arithmetic average of eligible results with non-detects treated as zero; instantaneous maximum NALs (total suspended solids, oil and grease, pH) are exceeded when two or more eligible results in a reporting year fall outside the level. Rules transcribed from 2014-0057-DWQ as amended by 2015-0122-DWQ (effective 2015-07-01, superseded 2020-06-30); 2014-0057-DWQ as amended by 2018-0028-DWQ (effective 2020-07-01).

Documents

Documents on file

Attachment inventory recorded in the State Water Board SMARTS public attachment workflow for this permit.

Source inventory — SMARTS public attachments. Documents are operator-submitted.

No document inventory has been indexed for this permit yet. The statewide document index is being built out; coverage is reported on the data-freshness panel.

Attachments for this permit remain viewable in the source system. Open the SMARTS public workflow

Enforcement

Enforcement records

Enforcement actions as recorded by the State Water Board for this permit, in the source system's own terminology.

Source record — SMARTS enforcement data

Structured enforcement records are not yet connected for this site. The absence of a record is not a finding about this facility.

Reporting

Reporting and ERA records

Annual report and Exceedance Response Action information as stated by the source system, distinguished from what is inferred from document metadata.

Source record — SMARTS reporting data

Structured reporting and ERA records are not yet connected for this site.

Recent activity

Recent source changes

New or changed source records this platform detected for this permit, newest first.

Derived

No source change has been detected for this permit yet. Change detection begins from the date each dataset was first indexed.

Provenance

Source & provenance

Source agency
California State Water Resources Control Board
Source dataset
Industrial General Permit — permitted facilities (statewide GIS layer)
WDID
8 36I022652
Source feature ID
16829
Application type
Notice of Intent
Regional board derivation
WDID region prefix
Geometry status
valid
Last successful facility import
Sep 16, 2026, 10:48 PM UTC

Official IGP permitted facilities feature layer