← Facilities

Industrial stormwater facility

US Marine Corps

WDID 6A26I005762 · Notice of Intent · Bridgeport, Mono

SIC 4581 · Airports, Flying Fields, and Airport Terminal Services · Regional Board 6 - Lahontan Region

Official record — State Water Resources Control Board, Industrial General Permit

Hydrologic

Geographic context

Official facility coordinate plotted against the associated Final 2026 Integrated Report impaired-water geometry.

Loading map…
  • Facility location (official coordinate)
  • Associated impaired-water geometry (Final 2026 Integrated Report)
  • YDOS-derived geographic context
  • Loading associated geometry…

Geometry shown is limited to waterbodies geographically associated with this facility. Geographic association does not establish a discharge connection, receiving-water connectivity, or causation.

Official facility point
38.25575, -119.23127
HUC12 subwatershed
Bridgeport Reservoir-East Walker River
HUC12 code
160503010110
Impaired-water associations (derived)
3

Official

Facility record

Facility name
US Marine Corps
WDID
6A26I005762
Application type
Notice of Intent
City
Bridgeport
County
Mono
ZIP
93517
Primary SIC code
4581
SIC description
Airports, Flying Fields, and Airport Terminal Services
Date active
1992-04-07
Regional Water Board
Regional Board 6 - Lahontan Region

303(d) context

Associated impaired waters

Grouped by derived geographic association class.

Derived

Subwatershed + nearby

2 waterbodies
East Walker River, above Bridgeport Reservoir

River & Stream · Integrated Report category 4b · Addressed by action other than a TMDL

Listed pollutants / stressors (1) Indicator Bacteria

Distance 0.49 km

Confidence high

Fact sheet

Bridgeport Reservoir

Lake & Reservoir · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (4) Mercury, Nitrogen, Phosphorus, Sedimentation/Siltation

Distance 0.59 km

Confidence high

Fact sheet

Same impaired-water subwatershed

1 waterbodies
East Walker River, below Bridgeport Reservoir

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (9) Arsenic, Iron, Manganese, Nitrogen, Oxygen, Dissolved, Phosphorus +3 more

Distance

Confidence low

Fact sheet

Associations are calculated from official facility coordinates, USGS HUC12 boundaries, and official 2026 impaired-water geometry. They do not establish a discharge connection or causation.

TMDL requirements

Water Board-stated TMDL waste load allocations applied to this industrial permit in SMARTS.

Official record — SMARTS TMDL dataset, State Water Board

No SMARTS TMDL requirement is recorded for this WDID. In the statewide TMDL export only permits in Regions 4, 8 and 9 currently carry industrial TMDL requirements, so an absence here is not a statement that the facility discharges to an unimpaired water.

Official monitoring

SMARTS monitoring

Self-reported industrial stormwater sampling results as submitted by the discharger to SMARTS.

Official record — SMARTS parameter data, State Water Board
Reported results
63
Sample events
17
Distinct parameters
6
Reporting years
2015 – 2016
First sample
2015-07-09
Latest sample
2017-01-09
Source regional dataset
Region 6A - South Lake Tahoe
Source retrieved
Aug 21, 2026

Official SMARTS public reports

Parameters reported

Reported results over time

Loading reported results…

Most recent reported results

Latest 25 of 63
Sample dateLocationParameterResultUnitsEvent
2017-01-09MCMWTC Airfield SP-3Ammonia as N, TotalDNQ 1(non-detect / est.)mg/LQualifying Storm Event
2017-01-09MCMWTC Airfield SP-3BOD, Biochemical oxygen demandDNQ 1(non-detect / est.)mg/LQualifying Storm Event
2017-01-09MCMWTC Airfield SP-3Chemical oxygen demand (COD)DNQ 1(non-detect / est.)mg/LQualifying Storm Event
2017-01-09MCMWTC Airfield SP-3Oil and Grease4.9mg/LQualifying Storm Event
2017-01-09MCMWTC Airfield SP-3pH7.28SUQualifying Storm Event
2017-01-09MCMWTC Airfield SP-3Total Suspended Solids (TSS)54mg/LQualifying Storm Event
2016-12-15MCMWTC Airfield SP-1Oil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2016-12-15MCMWTC Airfield SP-1pH10.3SUQualifying Storm Event
2016-12-15MCMWTC Airfield SP-1Total Suspended Solids (TSS)3mg/LQualifying Storm Event
2016-12-15MCMWTC Airfield SP-2Oil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2016-12-15MCMWTC Airfield SP-2pH8.32SUQualifying Storm Event
2016-12-15MCMWTC Airfield SP-2Total Suspended Solids (TSS)< 150(non-detect / est.)mg/LQualifying Storm Event
2016-12-15MCMWTC Airfield SP-3Oil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2016-12-15MCMWTC Airfield SP-3pH8.09SUQualifying Storm Event
2016-12-15MCMWTC Airfield SP-3Total Suspended Solids (TSS)> 87(non-detect / est.)mg/LQualifying Storm Event
2016-10-17MCMWTC Airfield SP-1Ammonia as N, TotalND (non-detect / est.)mg/LQualifying Storm Event
2016-10-17MCMWTC Airfield SP-1BOD, Biochemical oxygen demandND (non-detect / est.)mg/LQualifying Storm Event
2016-10-17MCMWTC Airfield SP-1Chemical oxygen demand (COD)ND (non-detect / est.)mg/LQualifying Storm Event
2016-10-17MCMWTC Airfield SP-1Oil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2016-10-17MCMWTC Airfield SP-1pH6.71SUQualifying Storm Event
2016-10-17MCMWTC Airfield SP-1Total Suspended Solids (TSS)33mg/LQualifying Storm Event
2016-10-17MCMWTC Airfield SP-2Ammonia as N, TotalND (non-detect / est.)mg/LQualifying Storm Event
2016-10-17MCMWTC Airfield SP-2BOD, Biochemical oxygen demandND (non-detect / est.)mg/LQualifying Storm Event
2016-10-17MCMWTC Airfield SP-2Chemical oxygen demand (COD)ND (non-detect / est.)mg/LQualifying Storm Event
2016-10-17MCMWTC Airfield SP-2Oil and GreaseND (non-detect / est.)mg/LQualifying Storm Event

Monitoring rows are official self-reported SMARTS submissions, joined to this facility by WDID. California Stormwater Intelligence does not restate, correct, average or evaluate reported values, and no benchmark comparison or violation determination is made.

YDOS-derived

Numeric Action Level comparison

Reported SMARTS analytical results compared against the Numeric Action Levels of the Industrial General Permit version in effect for each reporting year (July 1 – June 30).

Derived
Reporting years evaluated
2
Years with an NAL exceedance
2
Most recent evaluated year
RY 2016
Ruleset
igp_nal_ruleset_v1 / igp_nal_v1
ParameterNAL typeCalculated valueNALResultSamples usedMethod

Ammonia, Total (as N)

ammonia_n

Annual0 mg/L2.14 mg/LAt or below NALAnnual average of 1 eligible result(s) compared with the annual NAL.0× threshold1 eligible3 excluded1 non-detect as zeroarithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Biochemical Oxygen Demand (BOD) (5-day @ 20 Deg. C)

bod

Annual0 mg/L30 mg/LAt or below NALAnnual average of 1 eligible result(s) compared with the annual NAL.0× threshold1 eligible3 excluded1 non-detect as zeroarithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Chemical Oxygen Demand (COD)

cod

Annual0 mg/L120 mg/LAt or below NALAnnual average of 1 eligible result(s) compared with the annual NAL.0× threshold1 eligible3 excluded1 non-detect as zeroarithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Oil and Grease

oil_grease

Instantaneous maximum0 samples above25 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.4 eligible3 excluded3 non-detect as zerocount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

pH

ph

Instantaneous maximum2 samples above6 – 9 pH unitsOutside NAL range2 eligible results in this reporting year were outside the instantaneous maximum NAL. Two or more such results in one reporting year is the condition stated in the Order.7 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Total Suspended Solids (TSS)

tss

Instantaneous maximum0 samples above400 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.7 eligible1 non-detect as zerocount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

An NAL exceedance is a permit-defined condition that triggers Exceedance Response Actions under the Industrial General Permit. It is not a violation, an enforcement action, or a Water Board compliance determination. Annual values use the arithmetic average of eligible results with non-detects treated as zero; instantaneous maximum NALs (total suspended solids, oil and grease, pH) are exceeded when two or more eligible results in a reporting year fall outside the level. Rules transcribed from 2014-0057-DWQ as amended by 2015-0122-DWQ (effective 2015-07-01, superseded 2020-06-30); 2014-0057-DWQ as amended by 2018-0028-DWQ (effective 2020-07-01).

Documents

Documents on file

Attachment inventory recorded in the State Water Board SMARTS public attachment workflow for this permit.

Source inventory — SMARTS public attachments. Documents are operator-submitted.

No document inventory has been indexed for this permit yet. The statewide document index is being built out; coverage is reported on the data-freshness panel.

Attachments for this permit remain viewable in the source system. Open the SMARTS public workflow

Enforcement

Enforcement records

Enforcement actions as recorded by the State Water Board for this permit, in the source system's own terminology.

Source record — SMARTS enforcement data

Structured enforcement records are not yet connected for this site. The absence of a record is not a finding about this facility.

Reporting

Reporting and ERA records

Annual report and Exceedance Response Action information as stated by the source system, distinguished from what is inferred from document metadata.

Source record — SMARTS reporting data

Structured reporting and ERA records are not yet connected for this site.

Recent activity

Recent source changes

New or changed source records this platform detected for this permit, newest first.

Derived

No source change has been detected for this permit yet. Change detection begins from the date each dataset was first indexed.

Provenance

Source & provenance

Source agency
California State Water Resources Control Board
Source dataset
Industrial General Permit — permitted facilities (statewide GIS layer)
WDID
6A26I005762
Source feature ID
15314
Application type
Notice of Intent
Regional board derivation
WDID region prefix
Geometry status
valid
Last successful facility import
Sep 16, 2026, 10:48 PM UTC

Official IGP permitted facilities feature layer