San Francisco Bay, Central
2026 303(d) list Waterbody ID CAB2031201019981217171707 Bay & Harbor Region 2 · San Francisco Bay
At a glance
- 2026 listing Evidence: State-published
- On the 2026 303(d) list · 11 Appendix A decisions
- Category 5: a TMDL is required
- What a listing means
- Pollutants and stressors
- 11 pollutants in 5 Appendix A categories
- Metals (2) · Other Cause (1) · Pesticides (3) · Toxic Organics (4) · Trash (1)
- Listing decisions
- TMDL information Evidence: State-published
- 11 decisions with a TMDL requirement status; 4 name a TMDL project
- Status codes as published: 5A, 5B
- TMDL details
- Industrial stormwater facilities
- 6 report it as their receiving water Evidence: identification corroborated
- 551 within 1 km Evidence: geographic proximity
- Neither count establishes a discharge · Facilities
What a 303(d) listing means
The Clean Water Act section 303(d) list names waters that do not meet water quality standards for one or more pollutants or stressors. California publishes it in the Integrated Report; this page shows the 2026 decisions from Appendix A as published.
- A listing describes the condition of the waterbody. It does not identify which sources cause the impairment, and it does not by itself place a requirement on any particular facility.
- Listed waters do not all have the same status. The Integrated Report category says how an impairment is being addressed: 5, a TMDL is required; 4a, addressed by a USEPA-approved TMDL; 4b, addressed by other pollution control requirements; 4c, impairment not caused by a pollutant. This waterbody's decisions are in category 5.
- TMDL requirement status values (such as 5A or 5B) are shown exactly as published in Appendix A.
2026 listing status Evidence: State-published
- On the 2026 303(d) list
- Yes
- Appendix A decisions
- 11
- Integrated Report category
- 5 (a TMDL is required)
- Listing cycle
- 2026
- State Board adoption
- 2026-02-03 (Resolution 2026-0005)
- USEPA approval
- not confirmed — submittal letter to USEPA published; no approval found on the report page (checked 2026-10-22)
- Regional Water Board
- 2 — San Francisco Bay
Published by the State Water Resources Control Board (2026 California Integrated Report, Appendix A). Listing status is taken from Appendix A only. A listing describes the condition of this waterbody, not of any facility.
Location
Loading the waterbody shape…
Open this area on the statewide map · Browse impaired waters
Listing decisions and pollutants Evidence: State-published
Grouped by the Pollutant Category published in Appendix A. Pollutant names, categories and decisions are exactly as published.
Metals (2 decisions)
| Pollutant | Pollutant category | Category | Final listing decision | Decision status | Sources | Decision ID |
|---|---|---|---|---|---|---|
| Mercury | Metals | 5 | Do Not Delist from 303(d) list (being addressed with USEPA approved TMDL) | Revised | Atmospheric Deposition Industrial Point Sources Municipal Point Sources Natural Sources Nonpoint Source Resource Extraction | 153018 |
| Selenium | Metals | 5 | Do Not Delist from 303(d) list (being addressed with USEPA approved TMDL) | Revised | Major Industrial Point Source See TMDL documentation | 140903 |
Other Cause (1 decision)
| Pollutant | Pollutant category | Category | Final listing decision | Decision status | Sources | Decision ID |
|---|---|---|---|---|---|---|
| Invasive Species | Other Cause | 5 | Do Not Delist from 303(d) list (TMDL required list) | Revised | A Source Unknown | 170590 |
Pesticides (3 decisions)
| Pollutant | Pollutant category | Category | Final listing decision | Decision status | Sources | Decision ID |
|---|---|---|---|---|---|---|
| Chlordane | Pesticides | 5 | Do Not Delist from 303(d) list (TMDL required list) | Revised | A Source Unknown | 140844 |
| DDT (Dichlorodiphenyltrichloroethane) | Pesticides | 5 | Do Not Delist from 303(d) list (TMDL required list) | Revised | A Source Unknown | 148339 |
| Dieldrin | Pesticides | 5 | Do Not Delist from 303(d) list (TMDL required list) | Revised | A Source Unknown | 140859 |
Toxic Organics (4 decisions)
| Pollutant | Pollutant category | Category | Final listing decision | Decision status | Sources | Decision ID |
|---|---|---|---|---|---|---|
| Dioxin compounds (including 2,3,7,8-TCDD) | Toxic Organics | 5 | Do Not Delist from 303(d) list (TMDL required list) | Revised | A Source Unknown | 151207 |
| Furan Compounds | Toxic Organics | 5 | Do Not Delist from 303(d) list (TMDL required list) | Revised | A Source Unknown | 151209 |
| PCBs (Polychlorinated biphenyls) | Toxic Organics | 5 | Do Not Delist from 303(d) list (being addressed with USEPA approved TMDL) | Revised | A Source Unknown | 140899 |
| PCBs (Polychlorinated biphenyls) (dioxin-like) | Toxic Organics | 5 | List on 303(d) list (being addressed by USEPA approved TMDL) | Original | A Source Unknown | 69743 |
Trash (1 decision)
| Pollutant | Pollutant category | Category | Final listing decision | Decision status | Sources | Decision ID |
|---|---|---|---|---|---|---|
| Trash | Trash | 5 | Do Not Delist from 303(d) list (TMDL required list) | Revised | A Source Unknown | 151598 |
TMDL information Evidence: State-published
| Pollutant | TMDL requirement status | TMDL project | Priority | USEPA approval of TMDL | Expected attainment |
|---|---|---|---|---|---|
| Chlordane | 5A | — | Low | — | — |
| DDT (Dichlorodiphenyltrichloroethane) | 5A | — | Low | — | — |
| Dieldrin | 5A | — | Low | — | — |
| Dioxin compounds (including 2,3,7,8-TCDD) | 5A | — | Low | — | — |
| Furan Compounds | 5A | — | Low | — | — |
| Invasive Species | 5A | — | Low | — | — |
| Mercury | 5B | San Francisco Bay Mercury | — | 2008-02-12 | — |
| PCBs (Polychlorinated biphenyls) | 5B | San Francisco Bay PCBs | — | 2010-03-29 | — |
| PCBs (Polychlorinated biphenyls) (dioxin-like) | 5B | San Francisco Bay PCBs | — | 2010-03-29 | — |
| Selenium | 5B | San Francisco Bay Selenium - North Bay | — | 2016-08-23 | — |
| Trash | 5A | — | Low | — | — |
This is TMDL information for the waterbody. It does not establish that a TMDL applies to any particular facility. Facility-specific TMDL requirements recorded in SMARTS appear on facility pages and are not linked to this waterbody until reviewed.
HUC12 watersheds
Published with the listing Evidence: publisher-reported
- San Pablo Bay 180500020802
- Larkspur Creek-Frontal San Francisco Bay Estuaries 180500020902
- Arroyo Corte Madera Del Presidio-Frontal San Francisco Bay Estuaries 180500020903
- Cerrito Creek-Frontal San Francisco Bay Estuaries 180500020904
- Lobos Creek-Frontal San Francisco Bay Estuaries 180500020905
- Angel Island-Frontal San Francisco Bay Estuaries 180500021001
- Richardson Bay-San Francisco Bay 180500021002
- Sausal Creek-Frontal San Francisco Bay Estuaries 180500040805
- Visitacion Valley-Frontal San Francisco Bay Estuaries 180500040904
- San Francisco Bay Estuaries-Frontal San Francisco Bay 180500041001
The published list is truncated in Appendix A; it is not a complete list of watersheds.
Overlapping the waterbody's shape Evidence: spatial
- San Pablo Bay 180500020802 also published
- Larkspur Creek-Frontal San Francisco Bay Estuaries 180500020902 also published
- Arroyo Corte Madera Del Presidio-Frontal San Francisco Bay Estuaries 180500020903 also published
- Lobos Creek-Frontal San Francisco Bay Estuaries 180500020905 also published
- Angel Island-Frontal San Francisco Bay Estuaries 180500021001 also published
- Richardson Bay-San Francisco Bay 180500021002 also published
- Sausal Creek-Frontal San Francisco Bay Estuaries 180500040805 also published
- Visitacion Valley-Frontal San Francisco Bay Estuaries 180500040904 also published
- San Francisco Bay Estuaries-Frontal San Francisco Bay 180500041001 also published
- Oakland Inner Harbor-San Francisco Bay 180500041002
- San Pedro Creek-Frontal Pacific Ocean 180500060204
Industrial stormwater facilities
Evidence: identification corroborated
Shows: the facility named this waterbody as its receiving water in SMARTS, and the name and the facility's location are consistent with it. Does not establish: a discharge pathway, a discharge of any pollutant, or a cause of the listing.
Evidence: geographic proximity
Shows: the facility's reported location is within 1 km of the waterbody's mapped shape. Does not establish: that the facility discharges to this waterbody, or any other relationship.
Report this waterbody as their receiving water Evidence: identification corroborated
| Facility | WDID | Status | Distance from reported location | Map |
|---|---|---|---|---|
| Central Concrete Supply Treasure Island | 2 38I028773 | Terminated | 40 m | map |
| Sause Brothers Ocean Towing Company Inc | 2 07NEC011280 | Active | 47 m | map |
| Vulcan Materials Company Treasure Island | 2 38I031727 | Active | 103 m | map |
| American Soil | 2 01I028443 | Terminated | 318 m | map |
| Gold Bond Building Products LLC | 2 07I009260 | Active | 367 m | map |
| Nationwide Shotcrete Richmond | 2 07I028331 | Active | 643 m | map |
Receiving water reported by facility — waterbody identification corroborated by geographic evidence. 6 facilities.
Within 1 km of a facility's reported location Evidence: geographic proximity
Spatial proximity only; discharge pathway not established. Being near this waterbody does not mean a facility discharges to it.
| Facility | WDID | Status | Distance | Map |
|---|---|---|---|---|
| Dicon Fiberoptics Inc | 2 07I016813 | Terminated | 275 m | map |
| Big 4 Rents Inc | 2 01I009845 | Terminated | 276 m | map |
| Gallo Salame | 2 38I005932 | Terminated | 276 m | map |
| Hertz Equipment Rental Corp | 2 01I013072 | Terminated | 277 m | map |
| Maersk Line Terminal | 2 01I000519 | Terminated | 281 m | map |
| Stage Left Wineworks | 2 01NEC001841 | Terminated | 288 m | map |
| Zylidac Bio LLC | 2 01NEC015402 | Active | 288 m | map |
| Marine Terminals Corp Pier 80 | 2 38I014608 | Terminated | 289 m | map |
| Metro Ports Pier 80 | 2 38I021705 | Terminated | 289 m | map |
| Auto Warehousing Co | 2 07I021510 | Active | 289 m | map |
| Puglia Engineering Inc San Francisco Shipyard | 2 38I027113 | Terminated | 291 m | map |
| SF Boat Works | 2 38I004948 | Active | 291 m | map |
| Int Equipment Inc | 2 01I011152 | Terminated | 292 m | map |
| Dutra Const Co | 2 01I019095 | Terminated | 292 m | map |
| Outfront Media | 2 01NEC000564 | Terminated | 296 m | map |
| Pier 94 Batch Plant | 2 38I031732 | Active | 297 m | map |
| BP West Coast Products LLC | 2 07I002986 | Terminated | 298 m | map |
| BP West Coast Products LLC | 2 07I017029 | Terminated | 298 m | map |
| KMLT LLC Richmond Products Terminal | 2 07I026453 | Active | 298 m | map |
| Weyerhaeuser Paper | 2 01I006350 | Terminated | 298 m | map |
| Willig Freight Lines | 2 07I004638 | Terminated | 299 m | map |
| Three Harbor Services | 2 01IN607545 | NOI Required | 303 m | map |
| OMSS | 2 01I022890 | Terminated | 304 m | map |
| Plant Reclamation | 2 07I000960 | Terminated | 305 m | map |
| Advanced Lubrication Specialties | 2 07I030145 | Active | 306 m | map |
| Richmond City Water Pollution | 2 07I002117 | Terminated | 307 m | map |
| Pasha | 2 07I004943 | Terminated | 312 m | map |
| Richmond Terminal | 2 07I011983 | Terminated | 312 m | map |
| ConocoPhillips | 2 07I013150 | Terminated | 312 m | map |
| Test NEC R2 | 2 07NEC013783 | Terminated | 313 m | map |
| Sila Nano | 2 01NEC003129 | Active | 314 m | map |
| Berkeley Forge Tool Inc | 2 01I009954 | Terminated | 314 m | map |
| American Soil | 2 01I028443 | Terminated | 318 m | map |
| Fathom | 2 01NEC008603 | Terminated | 319 m | map |
| ABS Seafood Inc | 2 38I023624 | Active | 319 m | map |
| Pier 94 Import Yard | 2 38I016935 | Terminated | 321 m | map |
| TraPac Container Terminal Oakland | 2 01I010977 | Active | 322 m | map |
| Durham School Services | 2 01I029219 | Terminated | 324 m | map |
| Bay Area Rapid Transit Oakland | 2 01I009421 | Active | 324 m | map |
| Richmond Terminal | 2 07I021596 | Active | 328 m | map |
| Phillips 66 | 2 07I026087 | Active | 329 m | map |
| Falck Northern California | 2 01NEC006167 | Active | 329 m | map |
| Sks Die Casting | 2 01I002229 | Active | 331 m | map |
| Potrero Generating Station | 2 38I018853 | Terminated | 331 m | map |
| Pier 80 | 2 38I002835 | Terminated | 338 m | map |
| Am Pm Ser Co Inc | 2 01I017232 | Terminated | 340 m | map |
| Gasket Specialties Incorporated | 2 07NEC010719 | Terminated | 345 m | map |
| Port Oakland Harbor Facilities | 2 01I013232 | Terminated | 346 m | map |
| Ajax Auto Dismantlers | 2 38I024125 | Terminated | 350 m | map |
| GOLD SEAL PLATING | 2 01I009225 | Terminated | 351 m | map |
Sources and provenance
| Information | Source | Retrieved |
|---|---|---|
| Watershed Boundary Dataset HU2 GeoPackages 15, 16, 18 (WBDHU12) | USGS | 2026-10-22 |
| 2026 California Integrated Report, Appendix A: 2026 303(d) List (final) | SWRCB | 2026-10-22 |
| Final_2026_Rivers_and_Streams + Final_2026_Lakes_and_Reservoirs (FeatureServer 0) | SWRCB GIS | 2026-10-22 |
| SMARTS TMDL requirements | SMARTS | 2026-10-21 |
Relationships computed 2026-10-22 (facility_huc12/1, proximity/1, receiving_water/2, tmdl_reference/1, waterbody_huc12_ovl/1, waterbody_huc12_pub/1).
Integrated Report categories: 5, a TMDL is required; 4a, addressed by a USEPA-approved TMDL; 4b, addressed by other pollution control requirements; 4c, impairment not caused by a pollutant.