Coyote Creek (Santa Clara Co.)

2026 303(d) list Waterbody ID CAR2053002119990218112824 River & Stream Region 2 · San Francisco Bay

At a glance

2026 listing Evidence: State-published
On the 2026 303(d) list · 9 Appendix A decisions
Category 5: a TMDL is required
What a listing means
Pollutants and stressors
9 pollutants in 6 Appendix A categories
Metals (1) · Nutrients (1) · Other Cause (1) · Pesticides (4) · Total Toxics (1) · Trash (1)
Listing decisions
TMDL information Evidence: State-published
9 decisions with a TMDL requirement status; 5 name a TMDL project
Status codes as published: 5A, 5B, 5C
TMDL details
Regional Water Board
Region 2 · San Francisco Bay
River & Stream · Map
Industrial stormwater facilities
0 report it as their receiving water Evidence: identification corroborated
492 within 1 km Evidence: geographic proximity
Neither count establishes a discharge · Facilities

What a 303(d) listing means

The Clean Water Act section 303(d) list names waters that do not meet water quality standards for one or more pollutants or stressors. California publishes it in the Integrated Report; this page shows the 2026 decisions from Appendix A as published.

2026 listing status Evidence: State-published

On the 2026 303(d) list
Yes
Appendix A decisions
9
Integrated Report category
5 (a TMDL is required)
Listing cycle
2026
State Board adoption
2026-02-03 (Resolution 2026-0005)
USEPA approval
not confirmed — submittal letter to USEPA published; no approval found on the report page (checked 2026-10-22)
Regional Water Board
2 — San Francisco Bay

Published by the State Water Resources Control Board (2026 California Integrated Report, Appendix A). Listing status is taken from Appendix A only. A listing describes the condition of this waterbody, not of any facility.

Location

Loading the waterbody shape…

Listing decisions and pollutants Evidence: State-published

Grouped by the Pollutant Category published in Appendix A. Pollutant names, categories and decisions are exactly as published.

Metals (1 decision)

Metals: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
MercuryMetals5 List on 303(d) list (being addressed by USEPA approved TMDL)RevisedA Source Unknown 145429

Nutrients (1 decision)

Nutrients: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
Oxygen, DissolvedNutrients5 List on 303(d) list (TMDL required list)RevisedA Source Unknown 141884

Other Cause (1 decision)

Other Cause: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
Benthic Community EffectsOther Cause5 List on 303(d) list (TMDL required list)RevisedA Source Unknown 154205

Pesticides (4 decisions)

Pesticides: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
BifenthrinPesticides5 List on 303(d) list (being addressed by USEPA approved TMDL)RevisedOther Urban Runoff Surface Runoff 141903
CypermethrinPesticides5 List on 303(d) list (being addressed by USEPA approved TMDL)RevisedOther Urban Runoff Surface Runoff 141904
DiazinonPesticides5 Do Not Delist from 303(d) list (being addressed with USEPA approved TMDL)RevisedA Source Unknown Other Urban Runoff Surface Runoff 141870
PyrethroidsPesticides5 List on 303(d) list (being addressed by USEPA approved TMDL)RevisedOther Urban Runoff Surface Runoff 141896

Total Toxics (1 decision)

Total Toxics: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
ToxicityTotal Toxics5 Do Not Delist from 303(d) list (TMDL required list)RevisedA Source Unknown 141893

Trash (1 decision)

Trash: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
TrashTrash5 Do Not Delist from 303(d) list (being addressed with action other than TMDL)OriginalA Source Unknown 87976

TMDL information Evidence: State-published

TMDL information published for this waterbody
PollutantTMDL requirement statusTMDL projectPriorityUSEPA approval of TMDLExpected attainment
Benthic Community Effects5A— Low——
Bifenthrin5BSan Francisco Bay Urban Creeks Diazinon —2007-05-21—
Cypermethrin5BSan Francisco Bay Urban Creeks Diazinon —2007-05-21—
Diazinon5BSan Francisco Bay Urban Creeks Diazinon —2007-05-21—
Mercury5BSan Francisco Bay Mercury —2008-02-12—
Oxygen, Dissolved5A— Low——
Pyrethroids5BSan Francisco Bay Urban Creeks Diazinon —2007-05-21—
Toxicity5A— Low——
Trash5C— ——2029

This is TMDL information for the waterbody. It does not establish that a TMDL applies to any particular facility. Facility-specific TMDL requirements recorded in SMARTS appear on facility pages and are not linked to this waterbody until reviewed.

HUC12 watersheds

Published with the listing Evidence: publisher-reported

Overlapping the waterbody's shape Evidence: spatial

Industrial stormwater facilities

Evidence: identification corroborated

Shows: the facility named this waterbody as its receiving water in SMARTS, and the name and the facility's location are consistent with it. Does not establish: a discharge pathway, a discharge of any pollutant, or a cause of the listing.

Evidence: geographic proximity

Shows: the facility's reported location is within 1 km of the waterbody's mapped shape. Does not establish: that the facility discharges to this waterbody, or any other relationship.

Report this waterbody as their receiving water Evidence: identification corroborated

No facility's reported receiving water is identified as this waterbody.

Within 1 km of a facility's reported location Evidence: geographic proximity

Spatial proximity only; discharge pathway not established. Being near this waterbody does not mean a facility discharges to it.

Facilities whose reported location is within 1 km of this waterbody
FacilityWDIDStatusDistanceMap
Jabil Inc2 43NEC000390 Active907 m map
Velcon Filters Inc2 43I006010 Terminated909 m map
SanDisk Corporation2 43NEC001478 Terminated910 m map
Noah Medical Corporation2 43NEC013299 Active912 m map
GreenWaste MRF2 43I013752 Active913 m map
Mattson Technology2 01I026306 Active922 m map
Calogic Corp2 01I009485 Terminated923 m map
SM TECH2 43NEC009948 Terminated926 m map
Star Concrete2 43I016049 Terminated930 m map
Compass Transportation2 43I027739 Terminated934 m map
Andpak2 43I006749 Terminated935 m map
2030 Zanker Road (WH6)2 43NNA001452 No Action Required936 m map
2054 Zanker Road2 43NNA001455 No Action Required939 m map
Usps Bayside Station2 43I013043 Terminated940 m map
Dba Empex Ventures Inc2 43I012222 Terminated941 m map
Laidlaw Transit San Jose 7Th2 43I016041 Terminated941 m map
Yellow Checker Cab Co Inc2 43I021174 Terminated943 m map
Piedmont Transfer & Storage2 43I014828 Terminated944 m map
Piedmont Moving Systems2 43I015934 Terminated944 m map
Stapleton Spence Pkg2 43I006537 Terminated946 m map
Thin Film Electronics2 43I026841 Terminated947 m map
Thin Film Electronics2 43NEC004230 Active947 m map
Meraqi Viant Medical2 01NEC015596 Active958 m map
Jennings Tech Co LLC2 43I006584 Terminated958 m map
McNeal Enterprises2 43NEC005786 Active959 m map
Venice Tile & Marble2 43I024313 Terminated972 m map
JL Precision2 43I022897 Active975 m map
Amys Kitchen San Jose2 43NEC011140 Terminated976 m map
H P Machine and Eng Inc2 43IN605118 NOI Required978 m map
Miller Recycling2 43I027286 Terminated979 m map
U Save Rockery2 43I013709 Terminated979 m map
Valley Recycling Inc2 43I011635 Active980 m map
American Import Auto Dism2 43I006720 Active982 m map
GreenWaste Recovery Inc2 43I025108 Terminated984 m map
Green Team Materials Recovery2 43I017070 Terminated987 m map
Veeco Process Equipment Inc2 43NEC002837 Terminated987 m map
Pioneer Liquid Transport Inc2 43I027316 Active988 m map
Universal SemiConductor Inc2 43I017711 Active989 m map
Mac Cal Co2 43NEC009843 Active989 m map
Estes Express West2 43I007135 Active997 m map
Robles Brothers Inc2 43I028851 Terminated998 m map
Robles Brothers Inc2 43NEC013530 Active998 m map

492 facilities, nearest first. Page 10 of 10: previous

Sources and provenance

Sources behind this page
InformationSourceRetrieved
Watershed Boundary Dataset HU2 GeoPackages 15, 16, 18 (WBDHU12)USGS2026-10-22
2026 California Integrated Report, Appendix A: 2026 303(d) List (final)SWRCB2026-10-22
Final_2026_Rivers_and_Streams + Final_2026_Lakes_and_Reservoirs (FeatureServer 0)SWRCB GIS2026-10-22
SMARTS TMDL requirementsSMARTS2026-10-21

Relationships computed 2026-10-22 (facility_huc12/1, proximity/1, receiving_water/2, tmdl_reference/1, waterbody_huc12_ovl/1, waterbody_huc12_pub/1).

Integrated Report categories: 5, a TMDL is required; 4a, addressed by a USEPA-approved TMDL; 4b, addressed by other pollution control requirements; 4c, impairment not caused by a pollutant.