Coyote Creek

2026 303(d) list Waterbody ID CAR4051501019980917123914 River & Stream Region 4 · Los Angeles

At a glance

2026 listing Evidence: State-published
On the 2026 303(d) list · 8 Appendix A decisions
Category 5: a TMDL is required
What a listing means
Pollutants and stressors
8 pollutants in 6 Appendix A categories
Metals (3) · Other Cause (1) · Pathogens (1) · Pesticides (1) · Total Toxics (1) · Toxic Inorganics (1)
Listing decisions
TMDL information Evidence: State-published
8 decisions with a TMDL requirement status; 2 name a TMDL project
Status codes as published: 5A, 5B
TMDL details
Regional Water Board
Region 4 · Los Angeles
River & Stream · Map
Industrial stormwater facilities
60 report it as their receiving water Evidence: identification corroborated
353 within 1 km Evidence: geographic proximity
Neither count establishes a discharge · Facilities

What a 303(d) listing means

The Clean Water Act section 303(d) list names waters that do not meet water quality standards for one or more pollutants or stressors. California publishes it in the Integrated Report; this page shows the 2026 decisions from Appendix A as published.

2026 listing status Evidence: State-published

On the 2026 303(d) list
Yes
Appendix A decisions
8
Integrated Report category
5 (a TMDL is required)
Listing cycle
2026
State Board adoption
2026-02-03 (Resolution 2026-0005)
USEPA approval
not confirmed — submittal letter to USEPA published; no approval found on the report page (checked 2026-10-22)
Regional Water Board
4 — Los Angeles

Published by the State Water Resources Control Board (2026 California Integrated Report, Appendix A). Listing status is taken from Appendix A only. A listing describes the condition of this waterbody, not of any facility.

Location

Loading the waterbody shape…

Listing decisions and pollutants Evidence: State-published

Grouped by the Pollutant Category published in Appendix A. Pollutant names, categories and decisions are exactly as published.

Metals (3 decisions)

Metals: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
AluminumMetals5 List on 303(d) list (TMDL required list)RevisedA Source Unknown 153901
Copper, DissolvedMetals5 Do Not Delist from 303(d) list (being addressed with USEPA approved TMDL)OriginalA Source Unknown 68259
IronMetals5 Do Not Delist from 303(d) list (TMDL required list)RevisedA Source Unknown 132554

Other Cause (1 decision)

Other Cause: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
pHOther Cause5 Do Not Delist from 303(d) list (TMDL required list)RevisedA Source Unknown 132566

Pathogens (1 decision)

Pathogens: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
Indicator BacteriaPathogens5 Do Not Delist from 303(d) list (being addressed with USEPA approved TMDL)RevisedA Source Unknown 150537

Pesticides (1 decision)

Pesticides: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
MalathionPesticides5 Do Not Delist from 303(d) list (TMDL required list)RevisedA Source Unknown 132557

Total Toxics (1 decision)

Total Toxics: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
ToxicityTotal Toxics5 Do Not Delist from 303(d) list (TMDL required list)RevisedA Source Unknown 132573

Toxic Inorganics (1 decision)

Toxic Inorganics: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
ChlorineToxic Inorganics5 List on 303(d) list (TMDL required list)RevisedA Source Unknown 132541

TMDL information Evidence: State-published

TMDL information published for this waterbody
PollutantTMDL requirement statusTMDL projectPriorityUSEPA approval of TMDLExpected attainment
Aluminum5A— Low——
Chlorine5A— Low——
Copper, Dissolved5BSan Gabriel River Metals (39) —2007-03-27—
Indicator Bacteria5BSan Gabriel River Coliform (45) —2016-06-14—
Iron5A— Low——
Malathion5A— Low——
pH5A— Low——
Toxicity5A— Low——

This is TMDL information for the waterbody. It does not establish that a TMDL applies to any particular facility. Facility-specific TMDL requirements recorded in SMARTS appear on facility pages and are not linked to this waterbody until reviewed.

HUC12 watersheds

Published with the listing Evidence: publisher-reported

Overlapping the waterbody's shape Evidence: spatial

Industrial stormwater facilities

Evidence: identification corroborated

Shows: the facility named this waterbody as its receiving water in SMARTS, and the name and the facility's location are consistent with it. Does not establish: a discharge pathway, a discharge of any pollutant, or a cause of the listing.

Evidence: geographic proximity

Shows: the facility's reported location is within 1 km of the waterbody's mapped shape. Does not establish: that the facility discharges to this waterbody, or any other relationship.

Report this waterbody as their receiving water Evidence: identification corroborated

Facilities whose reported receiving water is identified as this waterbody
FacilityWDIDStatusDistance from reported locationMap
Advanced Sealing LLC4 19NEC003415 Terminated3.3 km map
MEC Manufacturing LLC4 19I030068 Active3.7 km map
Safeway Inc Beverage Plant4 19I002002 Terminated3.8 km map
Damco Distribution Services Inc4 19I029159 Active3.8 km map
PC Engineering LLC4 19I031407 Active4.2 km map
PC Engineering LLC4 19NEC007668 Terminated4.2 km map
Pioneer Truck and Auto Wrecking4 19I030436 Active4.3 km map
Andrew Lauren Surfaces Inc4 19I023393 Terminated4.4 km map
Fuji Food Products4 19I028713 Active4.5 km map
JBS4 19I026441 Terminated4.6 km map

Receiving water reported by facility — waterbody identification corroborated by geographic evidence. 60 facilities. Page 2 of 2: previous

Within 1 km of a facility's reported location Evidence: geographic proximity

Spatial proximity only; discharge pathway not established. Being near this waterbody does not mean a facility discharges to it.

Facilities whose reported location is within 1 km of this waterbody
FacilityWDIDStatusDistanceMap
Lucky Stores Inc4 19I001173 Terminated713 m map
Alloy Die Casting8 30I004030 Terminated713 m map
Alloy Die Casting Co8 30I013785 Active713 m map
CubeSmart 1578 30NNA002070 No Action Required728 m map
UPS La Mirada CALMD4 19I028399 Active735 m map
Four Seasons Building Products8 30I027998 Active736 m map
My Self Storage Space - Brea8 30NNA002048 No Action Required736 m map
Gold Coast Tours8 30I019511 Active740 m map
BI Technologies Corp8 30I001066 Terminated744 m map
Pharr Palomar Inc8 30I000142 Terminated745 m map
Unity Mold Inc8 30IN606593 No Action Required748 m map
UNITY MOLD8 30NEC010519 Active748 m map
INX International Ink Co8 30NEC015546 Active749 m map
Bigge Crane and Rigging Co4 19I024403 Terminated749 m map
Fullerton Joint Union High School District8 30I005104 Active750 m map
Du Du Group Inc4 19NEC013907 Active755 m map
Tomlin Scientific Inc8 30NEC002085 Active762 m map
National Signal LLC4 19I030972 Active763 m map
HB Fuller Inc Warehouse4 19I029836 Terminated764 m map
Tec Specialty Products LLC Warehouse4 19I031093 Active764 m map
American Allied Imaging8 30IN606256 NOI Required764 m map
Ray-Lite Industries Inc8 30IN606397 NOI Required764 m map
Magic Touch8 30IN606640 NOI Required764 m map
Lipomax Manufacturing Inc8 30NEC008680 Active764 m map
Ascension Cellars LLC8 30IN603895 No Action Required766 m map
B Line Systems Inc4 19I009557 Terminated770 m map
MedisourceRx8 30NEC007046 Active775 m map
Ganahl Lumber8 30I024055 Active778 m map
Ganahl Lumber8 30IN602272 NOI Filed778 m map
LF Audio8 30NEC016114 Active785 m map
Damac Products LLC4 19NEC004139 Terminated785 m map
New Source Forklift Parts Inc8 30IN606739 NOI Required796 m map
Dexter Magnetic Materials8 30I001691 Terminated798 m map
American Crating8 30NNA001906 No Action Required803 m map
14730 Northam St4 19NNA002398 No Action Required811 m map
Eurotec Seating Inc8 30IN606146 NOI Required819 m map
BRC Fabrication8 30IN606702 NOI Required820 m map
International Paper4 19NEC007641 Terminated820 m map
Sylvamo North America LLC4 19NEC016336 Active820 m map
Fullerton Fabrication8 30IN606807 NOI Required823 m map
Flex O Lite Inc4 19I005588 Terminated824 m map
National Signal Inc4 19I013606 Terminated824 m map
Cangemi Technologies8 30IN606459 NOI Required827 m map
PL Machine Corp8 30I029989 Active828 m map
Forged Works8 30IN606296 NOI Required829 m map
DC Wire EDM8 30IN606409 NOI Required829 m map
Boecking Machining8 30IN606460 NOI Required829 m map
Taylor Engine Rebuilding8 30IN606841 NOI Required829 m map
RE Fabricators8 30NEC005865 Active829 m map
Gemini Holdings, LLC8 30NNA000448 No Action Required829 m map

353 facilities, nearest first. Page 6 of 8: previous next

Sources and provenance

Sources behind this page
InformationSourceRetrieved
Watershed Boundary Dataset HU2 GeoPackages 15, 16, 18 (WBDHU12)USGS2026-10-22
2026 California Integrated Report, Appendix A: 2026 303(d) List (final)SWRCB2026-10-22
Final_2026_Rivers_and_Streams + Final_2026_Lakes_and_Reservoirs (FeatureServer 0)SWRCB GIS2026-10-22
SMARTS TMDL requirementsSMARTS2026-10-21

Relationships computed 2026-10-22 (facility_huc12/1, proximity/1, receiving_water/2, tmdl_reference/1, waterbody_huc12_ovl/1, waterbody_huc12_pub/1).

Integrated Report categories: 5, a TMDL is required; 4a, addressed by a USEPA-approved TMDL; 4b, addressed by other pollution control requirements; 4c, impairment not caused by a pollutant.