Verdugo Wash Reach 1 (LA River to Verdugo Rd.)

2026 303(d) list Waterbody ID CAR4052100019990202133541 River & Stream Region 4 · Los Angeles

At a glance

2026 listing Evidence: State-published
On the 2026 303(d) list · 3 Appendix A decisions
Category 4a: addressed by a USEPA-approved TMDL
What a listing means
Pollutants and stressors
3 pollutants in 3 Appendix A categories
Metals (1) · Pathogens (1) · Trash (1)
Listing decisions
TMDL information Evidence: State-published
3 decisions with a TMDL requirement status; 3 name a TMDL project
Status codes as published: 5B
TMDL details
Regional Water Board
Region 4 · Los Angeles
River & Stream · Map
Industrial stormwater facilities
0 report it as their receiving water Evidence: identification corroborated
48 within 1 km Evidence: geographic proximity
Neither count establishes a discharge · Facilities

What a 303(d) listing means

The Clean Water Act section 303(d) list names waters that do not meet water quality standards for one or more pollutants or stressors. California publishes it in the Integrated Report; this page shows the 2026 decisions from Appendix A as published.

2026 listing status Evidence: State-published

On the 2026 303(d) list
Yes
Appendix A decisions
3
Integrated Report category
4a (addressed by a USEPA-approved TMDL)
Listing cycle
2026
State Board adoption
2026-02-03 (Resolution 2026-0005)
USEPA approval
not confirmed — submittal letter to USEPA published; no approval found on the report page (checked 2026-10-22)
Regional Water Board
4 — Los Angeles

Published by the State Water Resources Control Board (2026 California Integrated Report, Appendix A). Listing status is taken from Appendix A only. A listing describes the condition of this waterbody, not of any facility.

Location

Loading the waterbody shape…

Listing decisions and pollutants Evidence: State-published

Grouped by the Pollutant Category published in Appendix A. Pollutant names, categories and decisions are exactly as published.

Metals (1 decision)

Metals: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
CopperMetals4a List on 303(d) list (being addressed by USEPA approved TMDL)OriginalA Source Unknown 75324

Pathogens (1 decision)

Pathogens: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
Indicator BacteriaPathogens4a Do Not Delist from 303(d) list (being addressed with USEPA approved TMDL)RevisedA Source Unknown 150341

Trash (1 decision)

Trash: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
TrashTrash4a List on 303(d) list (being addressed by USEPA approved TMDL)OriginalNonpoint Source Surface Runoff Urban Runoff/Storm Sewers 75494

TMDL information Evidence: State-published

TMDL information published for this waterbody
PollutantTMDL requirement statusTMDL projectPriorityUSEPA approval of TMDLExpected attainment
Copper5BLos Angeles River Metals (13) —2008-10-29—
Indicator Bacteria5BLos Angeles River Pathogens (15) —2012-03-23—
Trash5BLos Angeles River Trash (12) —2008-07-24—

This is TMDL information for the waterbody. It does not establish that a TMDL applies to any particular facility. Facility-specific TMDL requirements recorded in SMARTS appear on facility pages and are not linked to this waterbody until reviewed.

HUC12 watersheds

Published with the listing Evidence: publisher-reported

Overlapping the waterbody's shape Evidence: spatial

Industrial stormwater facilities

Evidence: identification corroborated

Shows: the facility named this waterbody as its receiving water in SMARTS, and the name and the facility's location are consistent with it. Does not establish: a discharge pathway, a discharge of any pollutant, or a cause of the listing.

Evidence: geographic proximity

Shows: the facility's reported location is within 1 km of the waterbody's mapped shape. Does not establish: that the facility discharges to this waterbody, or any other relationship.

Report this waterbody as their receiving water Evidence: identification corroborated

No facility's reported receiving water is identified as this waterbody.

Within 1 km of a facility's reported location Evidence: geographic proximity

Spatial proximity only; discharge pathway not established. Being near this waterbody does not mean a facility discharges to it.

Facilities whose reported location is within 1 km of this waterbody
FacilityWDIDStatusDistanceMap
SAMA Technology4 19NNA003331 No Action Required38 m map
Ta Mfg Co4 19I003523 Terminated66 m map
LA German Auto4 19I024670 Terminated93 m map
Jones Japanese Auto Parts4 19I024473 Terminated103 m map
American Reclamation4 19I004889 Active130 m map
Select Auto Dismantling4 19I018378 Terminated133 m map
XXX Auto Parts4 19I021790 Terminated133 m map
HI Tek Auto4 19I020046 Terminated134 m map
Red Line Auto Wrecking4 19I021592 Terminated134 m map
Hitek Foreign4 19I022315 Terminated134 m map
SDI INDUSTRIES4 19I009623 Terminated187 m map
Avo Transport Inc4 19NNA000821 No Action Required196 m map
AVO TRANSPORT INC4 19NNA000882 No Action Required196 m map
South Coast Recycling4 19I004890 Terminated211 m map
Public Storage4 19NNA000969 No Action Required263 m map
Jae CA Inc4 19I004189 Terminated264 m map
Sunland Chemical Research Co4 19I000812 Active299 m map
City of Glendale Grayson Power Plant4 19I001606 Terminated341 m map
Sun Valley Extrusion Co4 19I025958 Active348 m map
Golden Road Brewing4 19I028280 Terminated357 m map
Golden Road Brewing4 19NEC001391 Terminated364 m map
Glendale Mill Co4 19I001801 Terminated415 m map
Prc Desoto Int Inc4 19I016172 Terminated417 m map
Courtaulds Aerospace4 19I002382 Terminated426 m map
Admiral Control4 19I005082 Terminated448 m map
Recycling Buyback Facility4 19I005434 Terminated516 m map
Glendale City Buy Back Ctr4 19I015705 Terminated516 m map
Care Line Transportation, Inc4 19NNA001127 No Action Required564 m map
A G Layne Inc4 19I000358 Terminated601 m map
A G Layne Inc4 19I012219 Terminated601 m map
Jp Weaver Co4 19I013797 Active607 m map
Jp Weaver Co4 19I014174 Terminated607 m map
Glenair Inc4 19NEC002211 Active627 m map
National Ready Mixed Concrete4 19I002977 Active654 m map
World Auto Parts4 19I003901 Terminated679 m map
Barn Furniture Mart4 19I000801 Terminated709 m map
First Class Messenger Service Inc4 19NNA001244 No Action Required728 m map
Ames Rubber Manufacturing Co4 19I021668 Active748 m map
Glenair Inc4 19NEC002212 Active800 m map
Pacific Pipe Line Systems LLC4 19IN602670 NOI Required813 m map
5146 San Fernando4 19NNA001633 No Action Required860 m map
American Metaseal Com4 19I010849 Terminated908 m map
Ciba Specialty Chemicals Corp4 19I000914 Terminated914 m map
Ciba Geigy Corp Furane4 19I007038 Terminated914 m map
Vantico Inc4 19I015951 Terminated914 m map
Cube Storage4 19NEC010154 Active924 m map
Huntsman Advanced Materials Americas LLC4 19I017383 Active963 m map
Math Academia LLc4 19NNA001049 No Action Required995 m map

48 facilities, nearest first.

Sources and provenance

Sources behind this page
InformationSourceRetrieved
Watershed Boundary Dataset HU2 GeoPackages 15, 16, 18 (WBDHU12)USGS2026-10-22
2026 California Integrated Report, Appendix A: 2026 303(d) List (final)SWRCB2026-10-22
Final_2026_Rivers_and_Streams + Final_2026_Lakes_and_Reservoirs (FeatureServer 0)SWRCB GIS2026-10-22
SMARTS TMDL requirementsSMARTS2026-10-21

Relationships computed 2026-10-22 (facility_huc12/1, proximity/1, receiving_water/2, tmdl_reference/1, waterbody_huc12_ovl/1, waterbody_huc12_pub/1).

Integrated Report categories: 5, a TMDL is required; 4a, addressed by a USEPA-approved TMDL; 4b, addressed by other pollution control requirements; 4c, impairment not caused by a pollutant.