Rock Creek (Placer County)

2026 303(d) list Waterbody ID CAR5142201120090105143038 River & Stream Region 5 · Central Valley

At a glance

2026 listing Evidence: State-published
On the 2026 303(d) list · 1 Appendix A decision
Category 5: a TMDL is required
What a listing means
Pollutants and stressors
1 pollutant in 1 Appendix A category
Pathogens (1)
Listing decisions
TMDL information Evidence: State-published
1 decision with a TMDL requirement status
Status codes as published: 5A
TMDL details
Regional Water Board
Region 5 · Central Valley
River & Stream · Map
Industrial stormwater facilities
0 report it as their receiving water Evidence: identification corroborated
17 within 1 km Evidence: geographic proximity
Neither count establishes a discharge · Facilities

What a 303(d) listing means

The Clean Water Act section 303(d) list names waters that do not meet water quality standards for one or more pollutants or stressors. California publishes it in the Integrated Report; this page shows the 2026 decisions from Appendix A as published.

2026 listing status Evidence: State-published

On the 2026 303(d) list
Yes
Appendix A decisions
1
Integrated Report category
5 (a TMDL is required)
Listing cycle
2026
State Board adoption
2026-02-03 (Resolution 2026-0005)
USEPA approval
not confirmed — submittal letter to USEPA published; no approval found on the report page (checked 2026-10-22)
Regional Water Board
5 — Central Valley

Published by the State Water Resources Control Board (2026 California Integrated Report, Appendix A). Listing status is taken from Appendix A only. A listing describes the condition of this waterbody, not of any facility.

Location

Loading the waterbody shape…

Listing decisions and pollutants Evidence: State-published

Grouped by the Pollutant Category published in Appendix A. Pollutant names, categories and decisions are exactly as published.

Pathogens (1 decision)

Pathogens: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
Indicator BacteriaPathogens5 Do Not Delist from 303(d) list (TMDL required list)RevisedA Source Unknown 150342

TMDL information Evidence: State-published

TMDL information published for this waterbody
PollutantTMDL requirement statusTMDL projectPriorityUSEPA approval of TMDLExpected attainment
Indicator Bacteria5A— Low——

This is TMDL information for the waterbody. It does not establish that a TMDL applies to any particular facility. Facility-specific TMDL requirements recorded in SMARTS appear on facility pages and are not linked to this waterbody until reviewed.

HUC12 watersheds

Published with the listing Evidence: publisher-reported

None published.

Overlapping the waterbody's shape Evidence: spatial

Industrial stormwater facilities

Evidence: identification corroborated

Shows: the facility named this waterbody as its receiving water in SMARTS, and the name and the facility's location are consistent with it. Does not establish: a discharge pathway, a discharge of any pollutant, or a cause of the listing.

Evidence: geographic proximity

Shows: the facility's reported location is within 1 km of the waterbody's mapped shape. Does not establish: that the facility discharges to this waterbody, or any other relationship.

Report this waterbody as their receiving water Evidence: identification corroborated

No facility's reported receiving water is identified as this waterbody.

Within 1 km of a facility's reported location Evidence: geographic proximity

Spatial proximity only; discharge pathway not established. Being near this waterbody does not mean a facility discharges to it.

Facilities whose reported location is within 1 km of this waterbody
FacilityWDIDStatusDistanceMap
Mid Placer Sch Trans5S31I000706 Terminated49 m map
SMD One WWTP5S31I009013 Terminated84 m map
Morgan Advanced Materials5S31NEC015032 Active190 m map
Mid Placer Pub Schools Tran5S31I017901 Active195 m map
Recology Auburn Placer Transfer Station5S31I001657 Active337 m map
Auburn City Landfill5S31I016582 Terminated337 m map
Armstrong Technology Inc5S31I026104 Terminated339 m map
Armstrong Technology Inc5S31NEC012858 Active339 m map
Locksley Lane5S31I031257 Active344 m map
Durham Trans5S31I011234 Terminated417 m map
Quality Metal Fabrication5S31NEC016119 Active519 m map
Morgan Advanced Ceramics Inc5S31I002506 Terminated545 m map
Morgan Advanced Ceramics Inc5S31NEC015077 Active545 m map
Preserva Products5S31NEC006943 Active557 m map
Coherent Inc5S31I009536 Terminated651 m map
PASS LABORATORIES INC5S31NNA003620 NONA Submitted845 m map
Knee Deep Brewing Company LLC5S31NEC003385 Active869 m map

17 facilities, nearest first.

Sources and provenance

Sources behind this page
InformationSourceRetrieved
Watershed Boundary Dataset HU2 GeoPackages 15, 16, 18 (WBDHU12)USGS2026-10-22
2026 California Integrated Report, Appendix A: 2026 303(d) List (final)SWRCB2026-10-22
Final_2026_Rivers_and_Streams + Final_2026_Lakes_and_Reservoirs (FeatureServer 0)SWRCB GIS2026-10-22
SMARTS TMDL requirementsSMARTS2026-10-21

Relationships computed 2026-10-22 (facility_huc12/1, proximity/1, receiving_water/2, tmdl_reference/1, waterbody_huc12_ovl/1, waterbody_huc12_pub/1).

Integrated Report categories: 5, a TMDL is required; 4a, addressed by a USEPA-approved TMDL; 4b, addressed by other pollution control requirements; 4c, impairment not caused by a pollutant.