Santa Ana River, Reach 4

2026 303(d) list Waterbody ID CAR8012700019990211142130 River & Stream Region 8 · Santa Ana

At a glance

2026 listing Evidence: State-published
On the 2026 303(d) list · 3 Appendix A decisions
Category 5: a TMDL is required
What a listing means
Pollutants and stressors
3 pollutants in 3 Appendix A categories
Nuisance (1) · Pathogens (1) · Pesticides (1)
Listing decisions
TMDL information Evidence: State-published
3 decisions with a TMDL requirement status
Status codes as published: 5A
TMDL details
Regional Water Board
Region 8 · Santa Ana
River & Stream · Map
Industrial stormwater facilities
33 report it as their receiving water Evidence: identification corroborated
135 within 1 km Evidence: geographic proximity
Neither count establishes a discharge · Facilities

What a 303(d) listing means

The Clean Water Act section 303(d) list names waters that do not meet water quality standards for one or more pollutants or stressors. California publishes it in the Integrated Report; this page shows the 2026 decisions from Appendix A as published.

2026 listing status Evidence: State-published

On the 2026 303(d) list
Yes
Appendix A decisions
3
Integrated Report category
5 (a TMDL is required)
Listing cycle
2026
State Board adoption
2026-02-03 (Resolution 2026-0005)
USEPA approval
not confirmed — submittal letter to USEPA published; no approval found on the report page (checked 2026-10-22)
Regional Water Board
8 — Santa Ana

Published by the State Water Resources Control Board (2026 California Integrated Report, Appendix A). Listing status is taken from Appendix A only. A listing describes the condition of this waterbody, not of any facility.

Location

Loading the waterbody shape…

Listing decisions and pollutants Evidence: State-published

Grouped by the Pollutant Category published in Appendix A. Pollutant names, categories and decisions are exactly as published.

Nuisance (1 decision)

Nuisance: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
Oil and GreaseNuisance5 List on 303(d) list (TMDL required list)RevisedA Source Unknown 132875

Pathogens (1 decision)

Pathogens: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
Indicator BacteriaPathogens5 Do Not Delist from 303(d) list (TMDL required list)RevisedA Source Unknown 149175

Pesticides (1 decision)

Pesticides: Appendix A decisions
PollutantPollutant categoryCategoryFinal listing decisionDecision statusSourcesDecision ID
DDT (Dichlorodiphenyltrichloroethane)Pesticides5 List on 303(d) list (TMDL required list)RevisedA Source Unknown 149276

TMDL information Evidence: State-published

TMDL information published for this waterbody
PollutantTMDL requirement statusTMDL projectPriorityUSEPA approval of TMDLExpected attainment
DDT (Dichlorodiphenyltrichloroethane)5A— Low——
Indicator Bacteria5A— Low——
Oil and Grease5A— Low——

This is TMDL information for the waterbody. It does not establish that a TMDL applies to any particular facility. Facility-specific TMDL requirements recorded in SMARTS appear on facility pages and are not linked to this waterbody until reviewed.

HUC12 watersheds

Published with the listing Evidence: publisher-reported

Overlapping the waterbody's shape Evidence: spatial

Industrial stormwater facilities

Evidence: identification corroborated

Shows: the facility named this waterbody as its receiving water in SMARTS, and the name and the facility's location are consistent with it. Does not establish: a discharge pathway, a discharge of any pollutant, or a cause of the listing.

Evidence: geographic proximity

Shows: the facility's reported location is within 1 km of the waterbody's mapped shape. Does not establish: that the facility discharges to this waterbody, or any other relationship.

Report this waterbody as their receiving water Evidence: identification corroborated

Facilities whose reported receiving water is identified as this waterbody
FacilityWDIDStatusDistance from reported locationMap
County of San Bernardino Solid Waste Management8 36I030035 Terminated114 m map
Lineage Logistics 20638 36I029902 Active259 m map
Justice Cuts8 33I027750 Terminated362 m map
OG Pallets Inc8 36I028606 Active430 m map
Pacific Tank Lines Inc8 33I024938 Active479 m map
Custom Pipe & Fabrication8 36I031131 Active671 m map
CRST Riverside Training Center8 33I024438 Active810 m map
Riverside Hyponex Corporation8 36I028515 Terminated874 m map
Riverside Hyponex Corporation8 36I029832 Active874 m map
Riverside Hyponex Corporation8 36NEC011181 Terminated874 m map
Van Dyk Tank Lines Inc Cool Transports8 36I019252 Active1.0 km map
VERISTONE8 33I028251 Active1.1 km map
Retrofit Technology Inc8 36I022297 Terminated1.2 km map
Sulzer Electro Mechanical Service Inc8 36I028127 Active1.3 km map
Retrofit Technology LLC8 36I030283 Active1.4 km map
Vernon Transportation Company Southern California Yard8 33I027625 Terminated1.6 km map
Riverside Terminal8 33I030756 Active1.6 km map
Premier Silica LLC Riverside8 33I023780 Terminated1.7 km map
PSG Dover8 36I014030 Terminated2.1 km map
PSG Dover8 36I029454 Active2.1 km map
PSG Dover8 36NEC000217 Terminated2.1 km map
Western Pallet Supply & Logistics LLC8 33I030915 Active2.2 km map
System Transport8 36I028552 Terminated2.3 km map
Amazon com Services LLC SBD18 36I029363 Active2.4 km map
Cardlock Fuels System LLC8 36I027345 Active2.6 km map
Rise Baking Company LLC8 36I025877 Terminated3.1 km map
Rise Baking Company LLC8 36I030381 Active3.1 km map
PACKSMART LLC8 33I031010 Active3.6 km map
Southern Counties Oil Co a Cal LP dba SC Fuels8 36I024512 Terminated3.6 km map
Southern Counties Oil Co a Cal LP dba SC Fuels8 36I028855 Terminated3.6 km map
Southern Counties Oil Co a Cal LP dba SC Fuels8 36NEC002447 Terminated3.6 km map
Steel Unlimited Inc8 36I021983 Terminated3.7 km map
Merit Oil Company Bloomington8 36I019866 Active4.9 km map

Receiving water reported by facility — waterbody identification corroborated by geographic evidence. 33 facilities.

Within 1 km of a facility's reported location Evidence: geographic proximity

Spatial proximity only; discharge pathway not established. Being near this waterbody does not mean a facility discharges to it.

Facilities whose reported location is within 1 km of this waterbody
FacilityWDIDStatusDistanceMap
Stericycle DBE Riverside8 33NEC002218 Terminated505 m map
US Rubber Recycling Inc8 36I027501 Active508 m map
Sierra Aluminum8 33I002351 Active521 m map
So Cal Cold Store8 33I009122 Terminated521 m map
Inland Cold Storage Inc8 33I010537 Terminated521 m map
Fleetwood CA 308 33I001920 Terminated524 m map
Fleetwood Motor Homes8 33I019468 Terminated524 m map
FruitRipe Ripening Services8 33NEC010533 Active529 m map
Hydro Conduit Corp Colton8 36I000173 Terminated530 m map
Rinker Materials8 36NNA000349 No Action Required530 m map
IDC Logistics Inc8 36NEC014396 Terminated544 m map
Fleetwood Motor Homes CA8 33I002277 Terminated546 m map
East Coast West Coast Logistics dba The Gilbert Company8 36NEC010635 Terminated552 m map
Sworx Bottling Group LLC8 36I030963 Active554 m map
AIM Recycling8 36I027274 Active562 m map
Mission Plastics Incorporated8 36NEC004401 Active562 m map
Inland Cold Storage8 33I019286 Terminated571 m map
Lineage Logistics ICM LLC8 33I021572 Active571 m map
Preferred Pallets Inc8 33I030970 Active572 m map
Marlin Machine Products8 33NEC012817 Active583 m map
SDA8 36I010140 Terminated583 m map
Tube One Industries Inc8 33I030303 Active586 m map
Lytle Creek North WWTP8 36I020564 Active589 m map
Aristech Chemical Corp8 36I001946 Terminated591 m map
Ashland Chemical Co8 36I011750 Terminated591 m map
Rancho Ready Mix Inc8 36I010793 Terminated606 m map
Rancho Ready Mix8 36I020003 Active606 m map
Lilley Trans8 33I004269 Terminated657 m map
Imperial Pipe8 36I023682 Terminated659 m map
IDEAL PRODUCTS INC8 33NEC015653 Active666 m map
Custom Pipe & Fabrication8 36I031131 Active671 m map
Dura Coat Products Inc8 33I012306 Terminated689 m map
Primo Brands Colton8 36I025598 Active690 m map
Union Pacific Railroad8 36I030574 Terminated690 m map
CR England8 36I025297 Active696 m map
Walmart TMG 31658 36NEC011658 Active697 m map
Agua Mansa Properties dba WyRoc Materials8 36IN600301 No Action Required699 m map
Dura Coat Products Inc8 33I026870 Active703 m map
Augustine Metals Inc8 36I014876 Terminated709 m map
AFI Colton Main Plant8 36I025861 Terminated713 m map
AFI Colton Main Plant8 36NEC002511 Terminated713 m map
C and R Sales Inc dba Kretzschmar Steel8 36I026143 Terminated718 m map
C and R Sales Inc dba Kretzschmar Steel8 36I029327 Active718 m map
C and R Sales Inc dba Kretzschmar Steel8 36NEC003895 Terminated718 m map
Inland Compressing Company8 33MR000049 Active728 m map
Reclaimed Aggregates8 36NNA000325 No Action Required737 m map
Triman Medical Transport inc8 36NNA000781 No Action Required742 m map
Ecotech Consumer Products LLC8 36I030382 Active750 m map
Tom Son Tank Lines Inc8 36I011509 Terminated752 m map
Ecotech Consumer Products LLC8 36NEC011037 Terminated754 m map

135 facilities, nearest first. Page 2 of 3: previous next

Sources and provenance

Sources behind this page
InformationSourceRetrieved
Watershed Boundary Dataset HU2 GeoPackages 15, 16, 18 (WBDHU12)USGS2026-10-22
2026 California Integrated Report, Appendix A: 2026 303(d) List (final)SWRCB2026-10-22
Final_2026_Rivers_and_Streams + Final_2026_Lakes_and_Reservoirs (FeatureServer 0)SWRCB GIS2026-10-22
SMARTS TMDL requirementsSMARTS2026-10-21

Relationships computed 2026-10-22 (facility_huc12/1, proximity/1, receiving_water/2, tmdl_reference/1, waterbody_huc12_ovl/1, waterbody_huc12_pub/1).

Integrated Report categories: 5, a TMDL is required; 4a, addressed by a USEPA-approved TMDL; 4b, addressed by other pollution control requirements; 4c, impairment not caused by a pollutant.