← Facilities

Industrial stormwater facility

Santa Cruz Harbor Boatyard

3 44I024788 · Notice of Intent · Santa Cruz, Santa Cruz

Official record — State Water Resources Control Board, Industrial General Permit

Official

Facility record

Facility name
Santa Cruz Harbor Boatyard
WDID
3 44I024788
Application type
Notice of Intent
City
Santa Cruz
County
Santa Cruz
ZIP
95062
Primary SIC code
4493
SIC description
Marinas
Date active
2014-04-07
Regional Water Board
Regional Board 3 - Central Coast Region

Hydrologic

Geographic context

Official facility coordinate plotted against the official 2026 impaired-water geometry.

Official facility point
36.96727, -122.00123
HUC12 subwatershed
Monterey Bay
HUC12 code
180600150305
Impaired-water associations (derived)
6
Loading map…

303(d) context

Associated impaired waters

Grouped by derived geographic association class.

Derived

Subwatershed + nearby

3 waterbodies
Arana Gulch

River & Stream · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (4) Chlorpyrifos, Escherichia coli (E. coli), Toxicity, Turbidity

Distance 0.14 km

Confidence high

Fact sheet

Schwan Lake

Lake & Reservoir · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (3) Escherichia coli (E. coli), Nutrients, Total Coliform

Distance 0.46 km

Confidence high

Fact sheet

Pacific Ocean, Point Ano Nuevo to Soquel Point

Ocean · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (1) Dieldrin

Distance 0.59 km

Confidence high

Fact sheet

Nearby impaired water

3 waterbodies
Santa Cruz Harbor

Bay & Harbor · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (5) Arsenic, Copper, Dieldrin, Oxygen, Dissolved, PCBs (Polychlorinated biphenyls)

Distance 0.06 km

Confidence medium

Fact sheet

Pacific Ocean Shoreline at Twin Lakes Beach (Santa Cruz County)

Coastal & Bay Shoreline · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (1) Total Coliform

Distance 0.59 km

Confidence medium

Fact sheet

Pacific Ocean Shoreline at Seabright (Castle) Beach

Coastal & Bay Shoreline · Integrated Report category 5 · TMDL required

Listed pollutants / stressors (1) Total Coliform

Distance 0.62 km

Confidence medium

Fact sheet

Associations are calculated from official facility coordinates, USGS HUC12 boundaries, and official 2026 impaired-water geometry. They do not establish a discharge connection or causation.

TMDL requirements

Water Board-stated TMDL waste load allocations applied to this industrial permit in SMARTS.

Official record — SMARTS TMDL dataset, State Water Board

No SMARTS TMDL requirement is recorded for this WDID. In the statewide TMDL export only permits in Regions 4, 8 and 9 currently carry industrial TMDL requirements, so an absence here is not a statement that the facility discharges to an unimpaired water.

Official monitoring

SMARTS monitoring

Self-reported industrial stormwater sampling results as submitted by the discharger to SMARTS.

Official record — SMARTS parameter data, State Water Board
Reported results
351
Sample events
45
Distinct parameters
8
Reporting years
2015 – 2025
First sample
2015-04-02
Latest sample
2026-04-21
Source regional dataset
Region 3 - Central Coast
Source retrieved
Aug 21, 2026

Official SMARTS public reports

Parameters reported

Reported results over time

Loading reported results…

Most recent reported results

Latest 25 of 351
Sample dateLocationParameterResultUnitsEvent
2026-04-21BoatyardAluminum.285mg/LQualifying Storm Event
2026-04-21BoatyardCopper.8mg/LQualifying Storm Event
2026-04-21BoatyardIron.425mg/LQualifying Storm Event
2026-04-21BoatyardLead.0416mg/LQualifying Storm Event
2026-04-21BoatyardOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2026-04-21BoatyardpH6.64SUQualifying Storm Event
2026-04-21BoatyardTotal Suspended Solids (TSS)12mg/LQualifying Storm Event
2026-04-21BoatyardZinc.487mg/LQualifying Storm Event
2026-02-16BoatyardAluminum1.09mg/LQualifying Storm Event
2026-02-16BoatyardCopper.627mg/LQualifying Storm Event
2026-02-16BoatyardIron1.27mg/LQualifying Storm Event
2026-02-16BoatyardLead.0185mg/LQualifying Storm Event
2026-02-16BoatyardOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2026-02-16BoatyardpH6.68SUQualifying Storm Event
2026-02-16BoatyardTotal Suspended Solids (TSS)33mg/LQualifying Storm Event
2026-02-16BoatyardZinc.332mg/LQualifying Storm Event
2026-01-05BoatyardAluminum.314mg/LQualifying Storm Event
2026-01-05BoatyardCopper.781mg/LQualifying Storm Event
2026-01-05BoatyardIron.387mg/LQualifying Storm Event
2026-01-05BoatyardLead.0205mg/LQualifying Storm Event
2026-01-05BoatyardOil and GreaseND (non-detect / est.)mg/LQualifying Storm Event
2026-01-05BoatyardpH6.65SUQualifying Storm Event
2026-01-05BoatyardTotal Suspended Solids (TSS).012mg/LQualifying Storm Event
2026-01-05BoatyardZinc.406mg/LQualifying Storm Event
2025-12-16BoatyardAluminum.36mg/LQualifying Storm Event

Monitoring rows are official self-reported SMARTS submissions, joined to this facility by WDID. California Stormwater Intelligence does not restate, correct, average or evaluate reported values, and no benchmark comparison or violation determination is made.

YDOS-derived

Numeric Action Level comparison

Reported SMARTS analytical results compared against the Numeric Action Levels of the Industrial General Permit version in effect for each reporting year (July 1 – June 30).

Derived
Reporting years evaluated
11
Years with an NAL exceedance
11
Most recent evaluated year
RY 2025
Ruleset
igp_nal_ruleset_v1 / igp_nal_v1
ParameterNAL typeCalculated valueNALResultSamples usedMethod

Aluminum, Total

aluminum_total

Annual2.53 mg/L0.75 mg/LAbove NALAnnual average of 6 eligible result(s) compared with the annual NAL.3.37× threshold6 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Copper, Total

copper_total

Annual1.251 mg/L0.033 mg/LAbove NALAnnual average of 6 eligible result(s) compared with the annual NAL.37.69× threshold6 eligible1 non-detect as zeroarithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Iron, Total

iron_total

Annual3.02 mg/L1 mg/LAbove NALAnnual average of 6 eligible result(s) compared with the annual NAL.3.02× threshold6 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Lead, Total

lead_total

Annual0.034 mg/L0.262 mg/LAt or below NALAnnual average of 6 eligible result(s) compared with the annual NAL.0.13× threshold6 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

Oil and Grease

oil_grease

Instantaneous maximum0 samples above25 mg/LAt or below NALNo eligible result in this reporting year was outside the instantaneous maximum NAL.6 eligible6 non-detect as zerocount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

pH

ph

Instantaneous maximum0 samples above6 – 9 pH unitsWithin NAL rangeNo eligible result in this reporting year was outside the instantaneous maximum NAL.6 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Total Suspended Solids (TSS)

tss

Instantaneous maximum1 sample above400 mg/LAt or below NALOne eligible result in this reporting year was outside the instantaneous maximum NAL. The Order states the condition as two or more results in one reporting year.6 eligiblecount of eligible effluent results outside the instantaneous maximum NAL within the July 1 - June 30 reporting year

Zinc, Total

zinc_total

Annual0.64 mg/L0.26 mg/LAbove NALAnnual average of 6 eligible result(s) compared with the annual NAL.2.46× threshold6 eligiblearithmetic mean of all eligible effluent results in the July 1 - June 30 reporting year (censored results assigned zero only where MDL and ML were both reported)

YDOS-derived overlap

Pollutant overlap with impaired receiving waters

Parameters where this facility has an NAL exceedance in at least one reporting year and the geographically associated waterbody carries a 303(d) listing for the same pollutant.

Derived

CopperMonitoringAbove NAL303(d) impairmentSanta Cruz Harbor

11 reporting years above the annual NAL, most recently RY 2025 · 1 303(d) listing · association: derived receiving water (medium confidence)

Overlap is informational co-occurrence between a derived NAL comparison and an official 303(d) listing. It is not evidence that this facility caused or contributed to the impairment.

An NAL exceedance is a permit-defined condition that triggers Exceedance Response Actions under the Industrial General Permit. It is not a violation, an enforcement action, or a Water Board compliance determination. Annual values use the arithmetic average of eligible results with non-detects treated as zero; instantaneous maximum NALs (total suspended solids, oil and grease, pH) are exceeded when two or more eligible results in a reporting year fall outside the level. Rules transcribed from 2014-0057-DWQ as amended by 2015-0122-DWQ (effective 2015-07-01, superseded 2020-06-30); 2014-0057-DWQ as amended by 2018-0028-DWQ (effective 2020-07-01).

Provenance

Source & provenance

Source agency
California State Water Resources Control Board
Source dataset
Industrial General Permit — permitted facilities (statewide GIS layer)
WDID
3 44I024788
Source feature ID
11124
Application type
Notice of Intent
Regional board derivation
WDID region prefix
Geometry status
valid
Last successful facility import
Aug 21, 2026, 1:57 AM UTC

Official IGP permitted facilities feature layer